background image

 

 
 

OPERATIONAL & INSTRUCTION 

MANUAL 

 

Model:  3200FA 

(220v-240V 1Ø) 

 
 

Voltage Supply to Machine:  

 
 

L1 to L2: ___________ L1 to Ground: ____________ L2 to Ground ___________ 

 
 

UltraSonic LLC 

P.O. Box 54081 

Cincinnati, Ohio 45255 

 

Tel:  513-502-9746 
Fax: 513-702-2399 

 

[email protected] 

 

www.ultrasonicllc.com 

Summary of Contents for Ultra 3200FA

Page 1: ...FA 220v 240V 1Ø Voltage Supply to Machine L1 to L2 ___________ L1 to Ground ____________ L2 to Ground ___________ UltraSonic LLC P O Box 54081 Cincinnati Ohio 45255 Tel 513 502 9746 Fax 513 702 2399 info ultrasonicllc com www ultrasonicllc com ...

Page 2: ...on Never attempt to perform maintenance when cleaning solution is hot Never open equipment or attempt service warranty related repairs without first contacting UltraSonic LLC for safe and proper procedures SAFE OPERATION Do not immerse hands or other body parts in the ultrasonic tank Cleaning agents and contaminants can cause skin irritation and exposure to high intensity ultrasonic energy should ...

Page 3: ...tion if necessary Ultrasonic energy produced by the system is measurable by sound meters and OSHA sound restrictions may apply Do not leave the ultrasound on or leave parts in the tank longer than necessary This can result in erosion of the part surface and or the bottom of the tank Do not allow moisture to build up inside the unit this can cause electrical shorts and corrosion of the ultrasonic t...

Page 4: ... 220v 240V 1Ø Ultra 3200FA Have certified electrician connect power supply The unit may require a Buck Boost Transformer depending on incoming power Incoming Power above 240 volts will void Machine Warranty Flip rocker switch POWER ON up button Heater Control Ultrasonic lights will display green Operating temperature is pre set 150 F on the TEMP CONTROL Initial heat up time using cold water is app...

Page 5: ...UltraSonic LLC Model Ultra 3200FA 5 Control Panel ...

Page 6: ...See Program Settings 11 Up Navigation for Programing 12 Down Navigation for Programing Light Functions A Alarm Red Light Indicates Low Water or Overload B Agitation Green Light Indicates Activation C UltraSonic Green Light Indicates Activation D Heat Green Light Indicates Activation only when Heating Element is Working E Display Panel Shows Machine Functions Operation Instructions Control Panel Bu...

Page 7: ... panel SONIC Display Ultrasonic Timer AGIT Display Agitation Timer FILT Display Filtration Timer TEMP Display Actual Temperature Set Temperature Menu Operation Press Menu Button To select different Menu option press up button until desired Menu To return back to a Menu selection press down button to return To select desired Menu Option press Menu Button until edit position is reached then use Up a...

Page 8: ...ain to set Days use Up Down Buttons to set days check box to select day and exit press Menu Button to Time Set press Up Down to set start time press Menu Button to set finish time press Menu Button to Save Press UP Button to move to next setting Day AUX Control Set In Menu Press UP Button until Day AUX Control press Menu Button until Day Time On Off use Up Down Buttons to set ON or OFF Press Menu ...

Page 9: ... Remove basket NOTE Parts are hot use proper protective equipment to prevent exposure MAINTENANCE Preventative There is a minimum of preventive maintenance required The overall environment around the unit needs to be kept clean dry and dust free Routine Filter Element should be replaced when the pressure gauge indicates rise in pressure or the flow from the spray bar located in the front of the ma...

Page 10: ...urface and void warranty Wipe work and outside surfaces with a dry clean soft cloth When changing filter remove solution from front cleaning tank until water level is below spray bar Drain filter canister and use the special tool to loosen canister NOTE Canister and solution are hot and may be contaminated protective clothing and equipment should be used to prevent any exposure Insert filter eleme...

Page 11: ... cleaned it must be exposed to the liquid This requires proper placement of the parts in the parts basket Do not overload baskets with small parts that prevent the middle layers from getting proper exposure to the liquid Also improper placement of parts with blind holes or cavities can result in air pockets where no cleaning action occurs In general clean large numbers of parts a few at a time usi...

Page 12: ...LING ULTRASONIC LLC 513 502 9746 SPECIAL NOTE PLEASE RETAIN ORIGINAL SHIPPING CRATE Our service tech will help troubleshoot any problem and instruct user on the safe and proper procedures for repairs SUPPLIES AND SPARE PARTS For ordering supplies accessories or spare parts Visit our website www ultrasonicllc com Call to place your order 513 502 9746 ...

Page 13: ...ater Contactor KM 3 UltraSonic Generator Contactor KM 4 Agitation Motor Contactor QF 0 Main Ground Fault Breaker QF 1 Heater Circuit Breaker QF 2 UltraSonic Circuit Breaker QF 3 Agitation Circuit Breaker with overload RECT 1 24v Power Supply T 1 Transformer 120v MODV 01 PCB Control Board MODV 02 Control Board ...

Page 14: ...UltraSonic LLC Model Ultra 3200FA 14 ...

Page 15: ...UltraSonic LLC Model Ultra 3200FA 15 ...

Page 16: ...In no case shall UltraSonic LLC be responsible for any incidental or consequential damages This warranty does not apply to Equipment or components subjected to misuse improper installation alteration modification neglect or accident Use of unauthorized cleaning agents not approved by UltraSonic LLC Normal wear such as cavitation erosion of tank and transducer surfaces Non compliance with all proce...

Page 17: ...hine L1 to L2 ___________ L1 to Ground ____________ L2 to Ground ___________ I have received a copy of the Operational Instruction Manual I am aware that all personnel attempting to operate maintain or service the UltraSonic LLC Cleaning Equipment are required to read understand the Operational Instruction Manual Signed _________________________________________ Print Name _________________________...

Reviews: