Plumbing

Ozone and air is drawn into the water by the pump’s suction. It is mixed into the water by the pump’s
impeller. Ozone is then driven into the water by the pressure in the pipe between the pump and the
filter. The filter acts as an Ozone reaction-vessel. The air, with a very small amount of active Ozone,
is taken off the top of the filter sent to the pool through the returns. The ‘Champagne bubbles’ you
see returning in the pool are air and not hazardous to the environment or the pool equipment.

There are two ways your Inground UltraPure

Automatic Water Cleaner

can be plumbed into your

system. Please choose which method would be most appropriate for your pool. See Retrofit instal-
lation for Above ground pools.

BUILDER STANDPIPE INSTALLATION –  INGROUND

When the pool is being built or during renovation work, it can be made (Ozone) ready. With this
installation, a 3/4” suction side standpipe runs from below water level on a suction line, back to a
convenient location on the equipment pad. This will stop air from entering the pump. The 3/4” line
originates from below water level and there is no possibility to lose prime because there is a water
lock below grade.

“Tee in“ a 3/4” standpipe from (one of) the suction line(s) below water level and run it to a pro-
tected location behind the filter on the equipment pad. Cap the standpipe for pressure testing the
plumbing. When you are ready to install the UltraPure

Automatic Water Cleaner

, cut the cap

from the 3/4” standpipe and glue on our 3/4” FSL x 1/4” FPT reducing coupling. Apply Teflon tape
and screw in the 1/4” MPT x 3/8” straight compression fitting into the reducing coupling. The 1 1/2
lb. compression check valve is not required and should NOT be used with the method. Connect the
3/8” black tubing to the straight compression fitting and run the tubing back to the UltraPure

Automatic Water Cleaner

.

RETROFIT INSTALLATION –  INGROUND AND ABOVE GROUND

Apply Teflon tape and screw the 1 1/2 lb. Compression Check Valve or 1/2 lb. Compression Check
Valve for above ground units into the bottom drain plug hole of the strainer basket portion of the
pump. The straight compression fitting and reducing coupling are not required for this method.
Connect the black 3/8” tubing to the 1 1/2 lb. or 1/2 lb. compression check valve and run the tub-
ing back to the UltraPure

Automatic Water Cleaner

.

Note:

On inground pools, the possibility exists that air can enter the pump and water line through
the UltraPure

Automatic Water Cleaner

. Ensure that the 1 1/2 lb. Compression Check

Valve is not allowing air to bubble back into the pump basket when the pump is turned off.
If the check valve allows air to bubble back into the pump basket, call UltraPure Water Quality
Inc. at 877 281 7603.

Pool

Owner’s Manual and Installation Instructions

4

UltraPureManual12pg34072.indd   6

UltraPureManual12pg34072.indd   6

24.03.16   15:09

24.03.16   15:09

Summary of Contents for Automatic Water Cleaner UPAG20

Page 1: ...er s Manual and Installation Instructions FOR INGROUND AND ABOVE GROUND MODELS WATER QUALITY INC Part 3704700 UltraPureManual12pg34072 indd 1 UltraPureManual12pg34072 indd 1 24 03 16 15 09 24 03 16 15...

Page 2: ...tee 2 Specifications 3 Installation Location Mounting the UltraPure Water Cleaner Electrical 4 Plumbing Builder Standpipe Install Retrofit Install 5 Installation Instructions 6 External Safety Air Ble...

Page 3: ...death The UltraPure Automatic Water Cleaner must be installed in an outdoor location or indoors in a forced air ventilated room Warning Short term inhalation of high concentrations of ozone and long...

Page 4: ...free soft to the touch water Easy to manage pool water chemistry and balancing Compatibility with any chlorine source algaecides and minerals The lowest chemical use of any system While Ozone is not a...

Page 5: ...nect the UltraPure Automatic Water Cleaner to the pool timing clock so that the UltraPure operates simultaneously with the pool pump or plug your 120V unit into a grounded receptacle Above ground unit...

Page 6: ...for pressure testing the plumbing When you are ready to install the UltraPure Automatic Water Cleaner cut the cap from the 3 4 standpipe and glue on our 3 4 FSL x 1 4 FPT reducing coupling Apply Tefl...

Page 7: ...the metal grippers PRESSURE SIDE VENTURI INSTRUCTIONS kit sold separately See instructions included with the Pool Venturi Conversion Kit Part 1008079 For some applications a pressure side installatio...

Page 8: ...ump or on newer filters which will not evacuate the air See parts package included with your UltraPure Automatic Water Cleaner OPERATION To achieve optimal performance from the UltraPure Automatic Wat...

Page 9: ...the internal air bleed line inside the filter By ensuring this internal air bleed line is as close to the top of the filter as possible air readily escapes as the pump runs Where the External Safety A...

Page 10: ...lamp s in your UltraPure Automatic Water Cleaner may have difficulty starting The quartz ozone pro ducing lamp have mercury vapor inside and the cold temperature causes the mercury to condense and ma...

Page 11: ...areas c If no ASD is in the area the manufactured goods in need of service should be shipped with RGA to the address on the RGA form freight prepaid Any returned item deemed faulty due to manufacture...

Page 12: ...155 Appleby Line Unit E7 Burlington Ontario L7L 5H9 Canada Toll Free 877 281 7603 www waterquality net WATER QUALITY INC Part 3704700 UltraPureManual12pg34072 indd 12 UltraPureManual12pg34072 indd 12...

Reviews: