12Vdc Interface Board
Home-Run Wiring
Daisy-Chain Wiring (parallel)
Control Output
Dome
Interface Board
Control Output
1
st
Dome
Interface Board
2
nd
Dome
Interface Board
TX+
TB1-1 (+)
TX+
TB1-1 (+)
TX-
TB1-2 (-)
TX-
TB1-2 (-)
TB1-3 (+)
TB1-1 (+)
TB1-4 (-)
TB1-2 (-)
24Vac Interface Board (4x4 Electrical Box)
Home-Run Wiring
Daisy-Chain Wiring (parallel)
Control Output
Dome
Interface Board
Control Output
1
st
Dome
Interface Board
2
nd
Dome
Interface Board
TX+
TB2-4 (+)
TX+
TB2-4 (+)
TX-
TB2-3 (-)
TX-
TB2-3 (-)
TB2-2 (+)
TB2-4 (+)
TB2-1 (-)
TB2-3 (-)
3.
Video –
RG-59/U coaxial cable is recommended for cable runs less than 1500 feet (455
meters). For distances greater than 1500 feet, use RG-11 for distances up to 2500 feet (760
meters). If RG-11 coaxial cable is used, a UHF to BNC connector adapter is required. The
video must be terminated in 75 ohms at the last video device. If the video is not terminated
or double terminated, the resulting picture is poor and ghosting is displayed.
5.0
KD6 Z-SERIES DOME SETUP
Each KD6 Z-Series Dome must be given a unique address. The address (camera number) is
used by the operator at the control system to control the scan. The address is defined using a
JPD series controller. The serial number of the KD6 Z-Series Dome is required to set the
address. The serial number is located on the mounting bracket of the pan and tilt mechanism.
Refer to the KD6 Z-Series Dome operation and programming manual or the JPD Series
Controller manual for setting the address.