OPERATING
If you have NOT ordered a Loggia 7 day programmer to work with the electric radiant panel heater,
turn on the switch at the end of the radiator. The switch should illuminate to con
fi
rm that power is
now available to the heater. If the switch does not illuminate when operated,
fi
rst ensure that the
wall connection is switched on. If that does not solve the problem, then we recommend that you
consult your electrician.
Manual control
(when no programmer has been ordered)
Near to the switch referred to above, there is an LED which lights up red to indicate that the heater is warming up. The panel surface
temperature is factory preset. Please note, that in manual control, your heater will not automatically control room temperature.
If the LED shows green, and the heater does not warm up, it means that it may need to be set to operate in manual mode by following this
procedure:
A: If the panel is on, switch it o
Ƭ
.
B: Switch it on for about three seconds then switch it o
Ƭ
again.
Do this 5 times in succession, and your heater should be back in manual control.
In manual operating mode the heater can be switched on and o
Ƭ
by using the power switch on the heater, or via the supply point.
Should you in future require automatic room temperature and/or time control, then a LHC001/LHC005 control may be purchased
seperately. Speak to your Loggia retailer about this. Full instructions would be provided to enable the heater to be connected wirelessly.
Wireless room thermostat timer programmer
(optional purchase)
For wireless operation refer to the instructions provided with the LHC001/LHC005 7 day programmable thermostat/timer/
programmer.
Cleaning
To clean, simply wipe with a damp cloth, but do not allow any water to enter the heater.
SAFETY – OVERHEATING
All heaters are
Ʈ
tted with a thermal safety fuse. If the heater severely overheats then the thermal fuse will fail. When that occurs the heater
will not operate and must be returned to the manufacturer - via your Loggia retailer - for repair and servicing.
After sales service
Loggia electric radiant panel heaters have a one year warranty. Within this period Ultraframe will repair or exchange this product free of
charge provided it has been installed and operated correctly according to these instructions and has not been subjected to misuse.
Your rights under this guarantee are additional to statutory rights.
For after sales service contact your retailer. It would assist your retailer when processing your call if you can have available the serial
number and some details of the fault.
Please do not return a product you consider faulty without
Ʈ
rst obtaining returns approval.
PLEASE PASS THS INSTALLATION GUIDE TO THE HOMEOWNER/USER FOR FUTURE REFERENCE.