PUMP FOR HYDRAULIC SYSTEMS
-
page 11
of 71
Installation and maintenance manual
ULTRAFLEX
E
N
G
L
ISH
3.2Pump UP20 F installation
1
Select a suitable place for the steering station.
Make sure that there is enough manoeuvering space
for the steering wheel and for the steering pump and
its pipes and fittings.
In order to fix the pump properly, the maximum
dashboard thickness must be 30 mm [1,18 in.].
Different thicknesses could compromise the driving
safety. Make sure that the breaking ring of the 3 self-
locking nuts supplied is engaged by the dowel thread.
WARNING
3 INSTALLATION
3.1 Tools necessary for the installation of pump UP20F
2 Remove the plugs (1) from the pump (2) by using a
screwdriver.
3
Screw the nuts completely on the corresponding
90° unions (3), Fit and screw the unions manually as
indicated in the picture until they are inserted
completely. Turn them until they are positioned
correctly with respect to the pipes by unscrewing them
no more than one revolution, then tighten the nuts
with a 11/16" Allen wrench with a torque of 17,6 Nm
(13 lb ft) until the washer touches the nut.
DO NOT USE teflon tape or adhesive tape.
DO NOT PUT any thread sealant like Loctite 542 or
similar products.
WARNING
Torque
wrench
Drill
Open end
wrench
10 mm
Open end
wrench
11/16"
MOLYKOTE
®
1000
Screwdriver
Open end
wrench
19 mm
1
2
1
min. 82 mm [3,22 in.]
max. dashboard
thickness 30 mm [1,18
in.]]
System fitting
Connection for additional station
3
3
Connection for
a d d i t i o n a l
station