background image

                                                                

  

SEN 3

OFF

SEN 7

SEN 5

OFF

OFF

1

1

1

M-1234

PROGRAM

UL

TRA

UL

TRA

UL

TRA

UL

TRA

TOGGLE

SYSTEM PROGRAMMING - 

Menu 1

PAGE 24

90 & 95 SERIES

OWNER'S  MANUAL

LCD 2WAY

DOOR TRIGGER

THIS PAGE WOULD OCCUR IF 
A DOOR WAS OPENED ON THE 
VEHICLE.

ALARM TRIGGERS & PAGER MODE

WHEN THE ALARM IS TRIGGERED THE SYSTEM WILL PAGE THE REMOTE WITH THE 
SPECIFIC ALARM TRIGGER. THE REMOTE WILL START TO BEEP AND THE LCD WILL 
ALTERNATE BETWEEN “ALARM” AND THE “TRIGGER”

UL

TRA

ALARM

1

UL

TRA

DOOR

1

UL

TRA

ALARM

1

UL

TRA

SHOCK

1

UL

TRA

ALARM

1

UL

TRA

HOOD

1

UL

TRA

ALARM

1

UL

TRA

AUX

1

UL

TRA

ALARM

1

UL

TRA

PANIC

1

TOGGLE

TOGGLE

TOGGLE

TOGGLE

SHOCK TRIGGER

THIS PAGE WOULD OCCUR IF 
THE VEHICLE WAS IMPACTED 
HARD ENOUGH TO TRIGGER 
THE SHOCK SENSOR.

HOOD TRIGGER

THIS PAGE WOULD OCCUR IF 
A HOOD WAS OPENED ON THE 
VEHICLE.

AUX TRIGGER

THIS PAGE WOULD OCCUR IF 
THE AUXILIARY SENSOR 
INPUT IS TRIGGERED.

PANIC TRIGGER

THIS PAGE WOULD OCCUR IF 
THE SYSTEM WAS SET INTO 
PANIC MODE. (LOCK HELD 
FOR 3 SECONDS).

SYSTEM PROGRAMMING - 

Menu 1

PAGE 25

90 & 95 SERIES

OWNER'S MANUAL

LCD 2WAY

BRAKE FAULT

THIS FAULT WOULD OCCUR IF
THE BRAKE THERE WAS AN 
ISSUE WITH THE BRAKE 
CIRCUIT.

FAULT CODE VIA PAGER

IF THE STARTER FAILS TO START THE REMOTE WILL DISPLAY A FAULT CODE ON THE 
LCD DISPLAY. THE TEXT “FAULT” WILL BE FOLLOWED BY THE INPUT OR CONDITION 

UL

TRA

FAULT

1

UL

TRA

BRAKE

1

TOGGLE

HOOD FAULT

THIS FAULT WOULD OCCUR IF 
THE HOOD WAS OPENED OR 
THE HOOD SWITCH IS BROKE 
OR OUT OF ALIGNMENT. 

UL

TRA

FAULT

1

UL

TRA

HOOD

1

TOGGLE

TACH FAULT

THIS FAULT WOULD OCCUR IF
THE VEHICLE HAD A START 
ISSUE SUCH AS A DEFECTIVE 
BYPASS MODULE. 

UL

TRA

FAULT

1

UL

TRA

TACH

1

TOGGLE

VALET FAULT

THIS FAULT WOULD OCCUR IF
THE SYSTEM WAS IN VALET 
AND YOU PRESSED START. 

UL

TRA

FAULT

1

UL

TRA

VALET

1

TOGGLE

RANGE FAULT

THIS FAULT WOULD OCCUR IF
THE USER WAS OUT OF 
OPERATING RANGE. 

UL

TRA

FAULT

1

UL

TRA

RANGE

1

TOGGLE

PBRAKE FAULT

THIS FAULT WILL OCCUR IF
START IS PRESS WHEN NOT 
SET FOR RESERVATION MODE.
MANUAL TRANSMISSION ONLY.

UL

TRA

FAULT

1

UL

TRA

PBRAKE

1

TOGGLE

Summary of Contents for 90 Series

Page 1: ...SE AN AUTOMATIC TRANSMISSION STARTER IN A MANUAL TRANSMISSION VEHICLE REV 2011 7 30 AUTOMATIC AND MANUAL TRANSMISSION MODELS MUST USE M SERIES REMOTE STARTER AdvancedRemoteStarters VehicleSecuritySystems 90 95 SERIES ...

Page 2: ... PAGE 19 SHOCK SENSOR PROGRAMMING ALARM MODELS PAGE 20 21 LCD 2WAY REMOTE PAGES 22 25 DIAGNOSTICS PAGE 26 DIAGNOSTICS CHART DIAGNOSTIC MEMORY WARRANTY PAGE 27 CONTACT INFO PAGE 28 QUICK VIEW OPERATIONS 1WAY REMOTE PAGES 8 9 LOCK UNLOCK TRUNK START STOP ETC QUICK VIEW OPERATIONS LED 2WAY PAGES 10 11 LOCK UNLOCK TRUNK START STOP ETC SERVICE MODE PAGE 17 OVERRIDE MODE SERVICE MODE PAGER MODE OFF 3295...

Page 3: ...90 95SERIES IMPORTANT NOTES BEFORE YOU START ...

Page 4: ...START STOP UNLOCK PROGRAM STATUS UPDATE PGM MODE RESERVATION MODE ON M SERIES Basic Icon Description 1 2 ICON DESCRIPTION 1 USER MODE ICON 2 FEATURE STATUS 3 RANGE INDICATOR 4 TIMER MODE ICON 5 DISPLAY TEXT 6 PROGRAM MODE ICON 7 LOCK ICON 8 UNLOCK ICON 9 START RUN ICON 10 LOW TEMP MODE 11 TRUNK RELEASE ICON TRUNK RELEASE 1 2 ON OFF 4 TEXT PROGRAM 6 8 9 10 11 3 5 7 START STATUS 90 95SERIES LCD 2 WA...

Page 5: ...BEEPS PAUSE 1BEEP 1BEEP 2BEEPS 1BEEP PAUSE 1BEEP 1BEEP UNLOCKTHEDOORS DISARM THEALARM ALARMMODELSONLY TURNSOFFTHESIRENBUTTHEALARMWILLSTAYARMED ALARMMODELS TURNSOFFTHESIRENBUTTHEALARMWILLSTAYARMED ALARMMODELS ACTIVATESTHEDRIVER SDOORPRIORITYUNLOCKFEATURE MAYREQUIREADDITIONPARTSORLABOUR MUSTBE PROGRAMMEDFOROUTPUTTOACTIVATE DISPLAY BUTTON PRESS AUDIBLE FUNCTION 1 UNLOCK PRESS RELEASE WHILEALARMTRIGGE...

Page 6: ...NG DOOR CONTROL SUN ROOF OPEN CLOSE OR EVEN WINDOW ROLL UP THESE FUNCTIONS ARE OPTIONAL AND MAY REQUIRE ADDITION PARTS OR LABOUR MUST BE PROGRAMMED FOR OUTPUTS TO ACTIVATE M 1234 1 MELODY ENTERSREMOTEPROGRAM MODE SEEREMOTEPROGRAMMODESECTIONOFTHEMANUALFORMOREDETAILS REMOTE PROGRAM MODE ALLOWS THE USER TO SET OR CHANGE DEFAULT FEATURES OF THE SYSTEM SUCH AS TIMER MODE PAGER MODE VALET MODE SEE REMOT...

Page 7: ...VED KEY PRESS RELEASE WHILERUNNINGBYKEY TURBO 1 2 BEEPS ACTIVATESTHE TURBOTIMERMODEFEATURE THEVEHICLEWILLRUNFOR2MINUTESWHENTHEKEYISREMOVED PRESS RELEASE WHILERUNNINGBYKEY IF THE VEHICLE DOES NOT START A START FAULT CODE WILL BE DISPLAYED THE START FAULT WILL CLEAR THE NEXT TIME THE SYSTEM IS LOCKED OR UNLOCKED PLEASE SEE FAULT CODE SECTION OF MANUAL FOR MORE INFORMATION MANUAL TRANSMISSION RESERVA...

Page 8: ...OR 4 SECONDS 2 TURN OFF REMOTE STARTER START HOLD FOR 3 SECONDS CAR ON WITH KEY 2 ACTIVATES ENGINE IDLE MODE PRESS 2ND TIME WITHIN 3 SECONDS 2 2 ACTIVATES DRIVER S DOOR PRIORITY UNLOCK FEATURE HOLD FOR 5 SECONDS 2 TRUNK RELEASE OUTPUT AUX HOLD FOR 3 SECONDS RUNNING BY KEY 2 2 TURBO TIMER MODE STAYS RUNNING FOR 2 MINUTES DISPLAY BUTTON PRESS HONKS FLASH FUNCTION PRESS RELEASE ON WITH STARTER 1 ACTI...

Page 9: ...ILENT LOCK WITHOUT HONKS ACTIVATES SILENT UNLOCK WITHOUT HONKS PRESS TOGETHER FOR 3 SECONDS 2 ACTIVATES THE AUXILIARY 1 OUTPUT FOR 5 SECONDS AUX 1 PRESS TOGETHER FOR 3 SECONDS 2 ACTIVATES THE AUXILIARY 2 OUTPUT FOR UP TO 5 SECONDS AUX 2 USER NOTES 90 95SERIES 1 WAY REMOTE OPERATIONS PAGE 9 HONKS FLASH ...

Page 10: ...FOR 3 SECONDS 2 TURN OFF REMOTE STARTER START PRESS RELEASE CAR ON WITH KEY 2 ACTIVATES ENGINE IDLE MODE PRESS 2ND TIME WITHIN 3 SECONDS 2 2 ACTIVATES DRIVER S DOOR PRIORITY UNLOCK FEATURE HOLD FOR 5 SECONDS 2 TRUNK RELEASE OUTPUT AUX HOLD FOR 3 SECONDS RUNNING BY KEY 2 2 TURBO TIMER MODE STAYS RUNNING FOR 2 MINUTES DISPLAY BUTTON PRESS LED BEEPS FUNCTION PRESS RELEASE ON WITH STARTER 1 ACTIVATES ...

Page 11: ...ES SILENT LOCK WITHOUT HONKS ACTIVATES SILENT UNLOCK WITHOUT HONKS PRESS TOGETHER FOR 3 SECONDS 2 ACTIVATES THE AUXILIARY 1 OUTPUT FOR 5 SECONDS AUX 1 PRESS TOGETHER FOR 3 SECONDS 2 ACTIVATES THE AUXILIARY 2 OUTPUT FOR UP TO 5 SECONDS AUX 2 USER NOTES 90 95SERIES LED 2WAY REMOTE S PAGE 11 LED BEEPS ...

Page 12: ...me See diagnostic chart if your vehicle fails to start Note Manual transmission vehicles must be set for reservation mode before remote starting If your vehicle starts without setting reservation mode return to your dealer immediately as the incorrect remote starter has been installed Hold for 3 seconds or until the remote beeps on 2way models Alarm Models Default 15 minutes OR PRESS HOLD PAGE 12 ...

Page 13: ... Press twice on manual transmission models 90 95SERIES OR PRESS HOLD OR PRESS HOLD OR PRESS RELEASE PAGE 13 PRESS HOLD ...

Page 14: ...NG BRAKE THE PARK LIGHTS WILL FLASH AND THE HORN OPTIONAL WILL HONK TWICE 3 REMOVE THE KEY THE VEHICLE WILL STAY RUNNING 4 EXIT THE VEHICLE THE ENGINE WILL SHUT OFF WHEN THE DOOR IS CLOSED RESERVATION MODE WILL CANCEL IF A DOOR IS RE OPENED TO ENTER THE VEHICLE WITHOUT CANCELLING RESERVATION MODE REMOTE START THE VEHICLE THEN SHUT THE SYSTEM OFF BY THE REMOTE ONCE THE DOORS ARE CLOSED AGAIN NOTE L...

Page 15: ...OORS PRESS RELEASE Programmable Hold the Trunk button on LCD 2way models See 2way operations SYSTEM PROGRAMMING Menu 1 90 95SERIES OWNER S MANUAL SYSTEM OPERATIONS PAGE 15 OR 1 Press and hold the Trunk Release button on ...

Page 16: ...SYSTEM PROGRAMMING Menu 1 90 95SERIES OWNER S MANUAL SYSTEM OPERATIONS PAGE 16 ...

Page 17: ... Leave in the ON position Press and hold the Valet switch for 8 to 15 seconds Time depends on Valet Settings Program Option The horn siren will chirp 5 times as confirmation that the system is in Service Mode The LEDs on the antenna will turn on Solid DEACTIVATING SERVICE MODE Turn the Ignition Key ON Leave in the ON position Press and hold the Valet switch for 8 to 15 seconds Time depends on Vale...

Page 18: ...S UNLOCK SETS TEMP 2 PRESS START SETS TEMP 3 PRESS SETS TEMP 4 THE SYSTEM WILL START AT 5C 23F THE SYSTEM WILL START AT 15C 5F THE SYSTEM WILL START AT 25C 13F THE PARK LIGHTS WILL FLASH TO CONFIRM THE SELECTION ULTRA T E M P P R O G R A M TO ENTER PROGRAM MODE HOLD LOCK AND START FOR 5 SECONDS THE LCD WILL DISPLAY TEMP OFF THE PARK LIGHTS WILL FLASH AND THE HORN WILL HONK TWICE TO CONFIRM THAT LO...

Page 19: ...HE PROGRAM AND CLOCK ICONS TURN ON CLOCK SET MODE SYSTEM PROGRAMMING Menu 1 90 95SERIES OWNER S MANUAL SYSTEM OPERATIONS RUN TIME ADJUSTMENT M 1234 PROGRAM TO ENTER PROGRAM MODE PRESS AND HOLD THE BUTTON ON THE REMOTE FOR 4 SECONDS THE REMOTE WILL BEEP 3 TIMES THEN DISPLAY PROGRAM M 1234 PRESS START TO CONTINUE RUN TIME ADJUSTMENT PRESS UNLOCK BUTTON TO CHANGE TO 4 MINUTES PRESS START BUTTON TO CH...

Page 20: ...IGHEST MOST SENSITIVE SETTING IS SEN 10 PRESS AND RELEASE THE BUTTON ON THE REMOTE TO EXIT ENTER REMOTE PROGRAM MODE ADJUSTING THE SENSOR SENSITIVITY EXIT PROGRAM MODE SEN 3 OFF SEN 7 SEN 5 OFF OFF 1 1 1 M 1234 PROGRAM TO ENTER PROGRAM MODE PRESS AND HOLD THE BUTTON ON THE REMOTE FOR 4 SECONDS THE REMOTE WILL BEEP 1 TIME AND THEN 3 TIMES THE DISPLAY WILL SHOW PROGRAM M 1234 ENTER SHOCK SENSITIVITY...

Page 21: ...n on non alarm 2way systems it is recommended that the user switches the Pager Mode feature of the remote to OFF ULTRA 1 M 1234 PROGRAM ULTRA 1 ON OFF TIMER PROGRAM ULTRA ULTRA 1 2 3 1 2 3 ON OFF PAGER PAGER PROGRAM PROGRAM ULTRA 1 A 9 45 Hold for 4 seconds Press Release Press Release Press Release Press Release Pager Mode is now disabled and the battery life will be extended ...

Page 22: ...PRESS THE UNLOCK BUTTON TO TURN ON PRESS THE START BUTTON TO TURN OFF TURN PAGER ON OFF PRESS THE LOCK BUTTON TO SELECT PAGER MODE PRESS THE UNLOCK BUTTON TO TURN ON PRESS THE START BUTTON TO TURN OFF TURN VALET ON OFF PRESS THE LOCK BUTTON TO SELECT VALET MODE PRESS THE UNLOCK BUTTON TO TURN ON PRESS THE START BUTTON TO TURN OFF TIMER PROGRAM ON PAGER PROGRAM ON PRESS LOCK TO GO TO NEXT SETTING O...

Page 23: ... SENSOR ON OFF ALARM MODELS PRESS THE LOCK BUTTON TO SELECT SHOCK MODE PRESS THE UNLOCK BUTTON TO TURN ON PRESS THE START BUTTON TO TURN OFF SETS REMOTE TEMPERATURE DISPLAY FROM CELSIUS TO FAHRENHEIT PRESS THE LOCK TO SELECT CELSIUS PRESS THE UNLOCK TO SELECT FAHRENHEIT HORN PROGRAM ON PRESS LOCK TO GO TO NEXT SETTING OR STATUS TO EXIT PRESS LOCK TO GO TO NEXT SETTING OR STATUS TO EXIT PRESS LOCK ...

Page 24: ... AND THE LCD WILL ALTERNATE BETWEEN ALARM AND THE TRIGGER ULTRA ALARM 1 ULTRA DOOR 1 ULTRA ALARM 1 ULTRA SHOCK 1 ULTRA ALARM 1 ULTRA HOOD 1 ULTRA ALARM 1 ULTRA AUX 1 ULTRA ALARM 1 ULTRA PANIC 1 TOGGLE TOGGLE TOGGLE TOGGLE SHOCK TRIGGER THIS PAGE WOULD OCCUR IF THE VEHICLE WAS IMPACTED HARD ENOUGH TO TRIGGER THE SHOCK SENSOR HOOD TRIGGER THIS PAGE WOULD OCCUR IF A HOOD WAS OPENED ON THE VEHICLE AUX...

Page 25: ...D WAS OPENED OR THE HOOD SWITCH IS BROKE OR OUT OF ALIGNMENT ULTRA FAULT 1 ULTRA HOOD 1 TOGGLE TACH FAULT THIS FAULT WOULD OCCUR IF THE VEHICLE HAD A START ISSUE SUCH AS A DEFECTIVE BYPASS MODULE ULTRA FAULT 1 ULTRA TACH 1 TOGGLE VALET FAULT THIS FAULT WOULD OCCUR IF THE SYSTEM WAS IN VALET AND YOU PRESSED START ULTRA FAULT 1 ULTRA VALET 1 TOGGLE RANGE FAULT THIS FAULT WOULD OCCUR IF THE USER WAS ...

Page 26: ...ultrastarters com TROUBLE SHOOTING The LED s do not turn on when Tach Learning 1 The Tach wire input may be connected to the wrong wire Check the Tach location and connection then reset and relearn 2 The system may be in Tachless Mode On TL models the Tach wire connection is optional and the LED s do not turn on during the 35 second learn procedure When I unlock the doors the windows roll down or ...

Page 27: ...ays of the date of purchase to the address listed on the card the unit s date code or serial number is defaced missing or altered the unit has been modified or used in a manner contrary to its intended purpose the unit has been damaged by accident unreasonable use neglect improper service installation or other causes not arising out of defects in materials or construction The warranty does not cov...

Page 28: ...rams html This site is for registered and authorized dealer only If you are an authorized dealer but have been registered please fill out the service request form at http www ultrastarters com wiring_diagrams html PRODUCT INFORMATION www ultrastarters com TECHNICAL SUPPORT support ultrastarters com ORDERING orders ultrastarters com APPLICATED SECURITY TECHNOLOGIES INC UNIT 2 8334 FOOTHILL BLVD SUN...

Reviews: