Water Pressure Test 

It is important that a pressure test is carried out. High and low water pressure can result 
in either damage to or failure of the softener. We recommend the fitting of a pressure 
limiter should your pressure exceed 4 bar (58 psi). The minimum working pressure for the 
system is 1.4 bar (20 psi).

 

 

Starting The Installation 

Before starting the installation of the valves ensure that the stop cock is in the closed 
position. Once the valves have been fitted, set the valves as follows: 
 

Softener Inlet and Outlet valve CLOSED, Bypass valve OPEN

 

You can now safely return the stop cock to the open position. Using the hoses provided (if 
installation kit ordered) connect the straight end of the hose having first inserted the 
washer provided to the softener inlet and outlet valves. Connect the angled end of the 
hose to the softener. The inlets and outlets and drain are marked on the softener. 

 

Close the BYPASS and slowly OPEN the inlet and outlet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for Midnight

Page 1: ...d some of our water softners that would be suitable for you below SOFT WATER MODERATELY SOFT WATER SLIGHTLY HARD WATER MODERATELY HARD WATER HARD WATER VERY HARD WATER Your Water Softener Recommendati...

Page 2: ...future maintenance and salt replenishment Check the water pressure locate the rising main stop cock a drain facility and a power supply Unless you are replacing an existing water softener this instal...

Page 3: ...quately supported If the softener is being installed within your loft etc it is recommended to house the softener within a tank capable of storing at least 100 litres with an overflow fitted The overf...

Page 4: ...g The Installation Before starting the installation of the valves ensure that the stop cock is in the closed position Once the valves have been fitted set the valves as follows Softener Inlet and Outl...

Page 5: ...run of 8 meters with a minimum daytime pressure of 40 psi Ensure that the drain hose is not kinked or obstructed in any way as this will lead to an overflow of the softener The drain pipe can run uph...

Page 6: ...the softener To link the remote controller on the controller press up and down button for 3 seconds then press down to find SETID At this time connect the power on the softener Press the confirm butt...

Page 7: ...uage choices and press or to choose the language English is the top choice When English is highlighted press to save and to exit Time Of Day Press the Menu button to get into the Main menu Select Set...

Page 8: ...e Manual button and this will take it to the next stage of the regeneration this can be repeated to get to the end of the regeneration cycle Service Water flows into the valve at the top down through...

Page 9: ...rdness settings see the programming settings on page 7 The settings below should not be altered without good reason Within 6 seconds of switching on the power press and hold both and for 5 seconds to...

Page 10: ...sent B No salt in brine tank C Injector is plugged D Insufficient water is flowing into brine tank E Regeneration cycles not correct F Bad quality of feed water or turbine blocked G Adjusting bolt is...

Page 11: ...ng and reset Drain flows continuously A Internal valve leak B Power off when in back wash or fast rinse A Check and repair valve body or replace it B Adjust valve to service position or turn off bypas...