Water Pressure Test
It is important that a pressure test is carried out. High and low water pressure can result
in either damage to or failure of the softener. We recommend the fitting of a pressure
limiter should your pressure exceed 4 bar (58 psi). The minimum working pressure for the
system is 1.4 bar (20 psi).
Starting The Installation
Before starting the installation of the valves ensure that the stop cock is in the closed
position. Once the valves have been fitted, set the valves as follows:
Softener Inlet and Outlet valve CLOSED, Bypass valve OPEN
You can now safely return the stop cock to the open position. Using the hoses provided (if
installation kit ordered) connect the straight end of the hose having first inserted the
washer provided to the softener inlet and outlet valves. Connect the angled end of the
hose to the softener. The inlets and outlets and drain are marked on the softener.
Close the BYPASS and slowly OPEN the inlet and outlet