ULTRA REEF 

www.ultrareef.it

 

 

 

INSTRUCTION MANUAL 

 

Original manual. The product complies with Directive 

2006/42/CE. 

 

The Ultra Reef UCS range of calcium reactor integrates 

and maintains the level of calcium and alkalinity within 

an aquarium. The reactor is filled with calcium-based 

media and continuously filled with aquarium water 

that flows out slowly. Using the CO2 provided by the 

connected vessel, it lowers the pH of the water that 

recirculate in its interior to the point of dissolution of 

the medium, which slowly consumes and release 

carbonate and calcium ions (and other elements) 

constantly in the aquarium. 

 

Warning: The use of the product involves reading, 

understanding and acceptance of all conditions set 

forth in the "Safety" manual attached. If you do not 

find that manual immediately, contact our office! 

 

Clean thoroughly with water and vinegar (diluted to 

10%) each component that will go into contact with 

water. Products that contains alcohol or solvents can 

damage the acrylic. 

 

OVERVIEW 

 

Warning: Install the reactor inside the sump tank. 

Connect the reactor only to CO2 cylinders suitable for 

aquarium use and certified to comply with local laws. 

 

Before perform installation, prepare the medium. 

Follow the preparation instructions provided by the 

supplier of the media.  

 

Warning: This manual uses term "media" to indicate 

the filling material of the reactor. It is suggested to use 

a media consisting of coarse coral sand, size 10-20 

mm, carefully washed.  

 

Remove the top cover and place the reactor inside the 

tank sump. Spill into reactor earlier prepared media 

and close the cover, without forgetting the gasket. 

 

START 

 

When connecting hose insert the hose into the fitting 

and push it to the end. To remove it, push down the 

security ring and at same time pull the hose. Connect 

the pipes as shown:  

1. Water load hose H2O IN 

2. CO2 IN load hose 

3. Water drain hose H2O OUT 

4. Air vent hose O2 OUT  

 

Water load H2O IN:

  Use the supplied fittings to 

connect the water load hose to an existing pipeline or 

by installing a dedicated pump (suggested around 

1500 lit / h). 

 

Warning: Install a non-return valve (not supplied) on 

the CO2 load hose to prevent backflow of water into 

the cylinder or its valve. 

 

Warning: NEVER operate the reactor with fully closed 

drain valve. 

 

PH Probe:

  The use of a PH probe, relative controller 

and solenoid valve is optional. For the use of a PH 

probe, refer to the probe and solenoid valve controller 

manual.

 

For more information, ask to your trusted 

retailer. 

 

To start the reactor: 

1.

 

Remove the plug on the air vent hose. 

2.

 

Connect the water inlet (or start the pump load) 

of the reactor. Once the chamber is filled, the 

water will begin to overflow from the air vent 

hose and drain hose. 

3.

 

Loosen the upper connector on the bubble 

counter and fill it with water. 

4.

 

Shake gently the reactor in order to release the air 

bubbles trapped in the sand. 

5.

 

Replace the plug on the air vent hose and check 

that the reactor discharges only water from 

drainpipe. 

6.

 

Start the reactors pump. 

7.

 

Close off the output valve until you get a flow of 

between 1 and 2 l/h. 

8.

 

Open the carbon dioxide cylinder valve and adjust 

the output pressure of 0.1 bar. 

9.

 

Verify the release of CO2 into the reactor through 

the bubble counter.  

 

SETTING   

 

If air should accumulate in the reactor, remove the 

plug on the air vent hose and release it out. 

 

Manual calibration: 

Act on the control valve of the 

CO2 until you get a flow of about one bubble per 

second. 

 

PH controller calibration:

 Act on control valve of the 

CO2 until you get a flow of about 2 bubbles per 

second. Calibrate the controller so that it closes the 

solenoid valve when it detects a pH of about 6.80. 

 

Summary of Contents for UCS-140

Page 1: ...ULTRA REEF www ultrareef it 1 MANUALE ISTRUZIONI INSTRUCTIONS MANUAL BEDIENUNGSANLEITUNG V 2018 01 UCS 140 UCS 180 ITALIANO ENGLISH DEUTSCH...

Page 2: ...ULTRA REEF www ultrareef it 2...

Page 3: ...ULTRA REEF www ultrareef it 3...

Page 4: ...ULTRA REEF www ultrareef it 4...

Page 5: ...ULTRA REEF www ultrareef it 5...

Page 6: ...ULTRA REEF www ultrareef it 6...

Page 7: ...ondo Per estrarlo abbassate il collarino di sicurezza e contemporaneamente tirate il tubo Collegate le tubazioni come da schema 1 Tubazione carico acqua H2O IN 2 Tubazione carico CO2 IN 3 Tubazione sc...

Page 8: ...amente 25 30 KH Regolazione Controller PH Dopo la modifica del flusso in uscita non dovrebbe essere necessario regolare l apporto di CO2 poich regolato automaticamente dall elettrovalvola MANUTENZIONE...

Page 9: ...down the security ring and at same time pull the hose Connect the pipes as shown 1 Water load hose H2O IN 2 CO2 IN load hose 3 Water drain hose H2O OUT 4 Air vent hose O2 OUT Water load H2O IN Use th...

Page 10: ...ging the output flow it would not be necessary to adjust the CO2 intake as the solenoid valve automatically adjusts it MAINTENANCE Before performing any maintenance disconnect the product from power s...

Page 11: ...Deckel abnehmen und den Reaktor in das Technikbecken stellen F llen Sie in den Reaktor mit den zuvor vorbereiteten Medien und schlie en Sie den Deckel ohne die Dichtung zu vergessen START Beim Anschli...

Page 12: ...ufuhr so lange zu regeln bis die richtige Karbonath rte in der Regel 25 30 KH erreicht ist PH Reglerregelung Nach nderung des Austrittsmenge ist es nicht mehr notwendig die CO2 Zufuhr einzustellen da...

Reviews: