HyperSpike
®
MA-Micro Installation and Mounting Manual
90145A-MAN-MAMICRO Rev A
Page 4
3.0 FIELD WIRING
WARNING: EXPLOSION HAZARD. DO NOT DISCONNECT THE EQUIPMENT
UNLESS POWER HAS BEEN SWITCHED OFF OR UNLESS THE AREA IS KNOWN
TO BE NON-HAZARDOUS.
3.1. Cable Routing
3.1.1. Leaded Systems
The MA- Micro system comes with a 10-foot long 3/4” flexible conduit and 11-foot 14 AWG
lead. The connection at the end of the conduit requires an installer-supplied junction box
with a rating suitable for the installation environment of the box. See figure 3 for an
example.
Route the conduit to a junction box approved by local electrical codes and standards.
Follow your integrator’s instructions for installing into an appropriate junction system.
Figure 3: Example of field wiring