background image

HyperSpike

®

 LineWave Installation and Maintenance Manual 

 

 
 

 

Copyright © Ultra Electronics 

– USSI, Columbia City, IN 46725 USA

 

  90243A-MAN-LINEWAVE  Rev C 

Page 10 

 

2.7.   72544B-801 

– Wall Mounting Kit Installation: 

 

Reference the following instructions to install a LineWave 90243A-801 or 90243A-802 on a 
wall surface:

 

 

1.  Fasten two L Brackets (Part B) to the wall surface using appropriate fasteners for the wall. 

Always follow local codes and safety practices. 

Wall fasteners are not included in the 

mounting kit. 

a.  90243A-803 -  L Bracket 

recommended spacing is 20” apart.

 

b.  90243A-804 -  L Bracket r

ecommended spacing is 43” apart.

 

 

 

Figure 8.  90243A-803 and 90243A-804 Wall Mounting 

– Step 1 

 

 
 
 
 
 
 
 

Summary of Contents for HyperSpike LineWave Series

Page 1: ...Installation and Maintenance Manual HyperSpike LineWave...

Page 2: ...NGE TO ISSUE DATE WILL AFFECT RELATED LABELS WARNING EXPORT RE EXPORT AND TRANSFER OF THIS TECHNICAL DATA IS REGULATED BY US EXPORT ADMINISTRATION REGULATIONS AND MAY BE SUBJECT TO LICENSING REQUIREME...

Page 3: ...ansformer Recommended Hole Locations and Alignment 6 2 4 72542B 80X Circuit Breaker Reset 7 2 5 Wall Mounting 8 2 6 72544B 802 Wall Mounting Kit Installation 9 2 7 72544B 801 Wall Mounting Kit Install...

Page 4: ...NING EXPLOSION HAZARD DO NOT DISCONNECT THE EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR UNLESS THE AREA IS KNOWN TO BE NON HAZARDOUS AVERTISSEMENT RISQUE D EXPLOSION NE D BRANCHEZ PAS L QUIPEMENT...

Page 5: ...even coverage across the listening plane while focusing the acoustic pattern away from surfaces that cause unwanted reflections This technology is essential for achieving optimum levels of speech inte...

Page 6: ...color options The following breakdown describes the model number configurations 90243A 80X 0X L Certification N A Uncertified L UL 1480 1480A certified Color Code 01 Black 05 Red 06 White 07 Silk Gre...

Page 7: ...Reverb SPL 10 ft 18V Direct Drive 87 8 91 7 94 3 95 7 Anechoic SPL 3m 18V Direct Drive 93 4 98 0 103 0 104 0 Input Sensitivity 2 83Vrms 1m 85dB 91dB 97dB 103dB Nominal Impedance 16 8 4 4 2 Channel Ver...

Page 8: ...Weight 3lbs 4 5lbs 6 5lbs 2 Installation LineWave speakers are by default configured as 4 8 or 16 loudspeakers however an optional line matching transformer is available if it is desired to connect t...

Page 9: ...2 Wiring Diagram 90243A 804 2 2 Distributed Audio System Overview An optional 25V 70V 100V transformer allows the LineWave to be connected to 25V 70V or 100V distributed audio networks It has four fi...

Page 10: ...e s SJOOW cable to the transformer assembly utilize the included Strain Relief Cord Connector This connector requires a 0 740 hole to be drilled in the transformer assembly Consult the following recom...

Page 11: ...nsformer Lid Orientation 2 4 72542B 80X Circuit Breaker Reset Transformer 72542B 80X has an integrated circuit breaker that protects itself from line surges and short circuits The circuit breaker is l...

Page 12: ...Included Wall Mounting Kit 72544B 802 72544B 802 72544B 801 72544B 801 The following tables list the hardware included in the 72544B 801 and 72544B 802 wall mounting kits 72544B 801 Wall Mounting Kit...

Page 13: ...or the wall according to local codes and safety practices Wall fasteners are not included in the mounting kit 2 Insert two T Nuts Part H into the slot on the back of the LineWave and attach Pivot Nub...

Page 14: ...tions to install a LineWave 90243A 801 or 90243A 802 on a wall surface 1 Fasten two L Brackets Part B to the wall surface using appropriate fasteners for the wall Always follow local codes and safety...

Page 15: ...two Tie Bars Part C to Pivot Nub Part A using two flat washers Part D 1 5 8 long screw Part E and lock nut Part F as shown in Figure 9 Figure 9 90243A 803 and 90243A 804 Wall Mounting Step 2 3 Attach...

Page 16: ...A 90243A MAN LINEWAVE Rev C Page 12 4 Insert four T Nuts Part H into the slot on the back of the LineWave and attach two Pivot Nubs Part A 1 from each end using four 1 long screws Part J On the bottom...

Page 17: ...LineWave fasten the top Pivot Nub to the Tie Bars from step 1 using 1 5 8 Long Screw Part E two Flat Washers Part D and Lock Nut Part F Figure 12 90243A 803 and 90243A 804 Wall Mounting Step 5 6 To ai...

Page 18: ...eWave Slide the Pivot Nub up and down to adjust the tilt angle to the desired orientation as shown in Figure 14 The LineWave may need to be temporarily rotated left or right in order to access the scr...

Page 19: ...available for LineWave models 90243A 803 and 90243A 804 which allows mounting to poles ranging from 3 7 in diameter This kit is used in conjunction with the wall mounting hardware supplied with the sp...

Page 20: ...acket Part L using two flat washers Part D two lock nuts Part F and two 1 long screws Part J Repeat process with second bracket Figure 16 72581B 801 Pole Mounting Step 1 2 Fasten the Pole Mount Bracke...

Page 21: ...Draw Watts dB SPL Max 1M A Weighted dB SPL Reverb 10ft dB SPL Anechoic 3m 90243A 801 25V Blue 0 5 86 72 4 78 2 25V Orange 1 3 91 77 1 82 2 25V Red 1 6 92 78 2 83 8 25V Brown 2 7 94 79 9 85 3 70V Blue...

Page 22: ...ineWave Installation and Maintenance Manual Copyright Ultra Electronics USSI Columbia City IN 46725 USA 90243A MAN LINEWAVE Rev C Page 18 3 2 72575B 801 Transformer Wiring Guide Used for 90243A 801 an...

Page 23: ...ghted dB SPL Reverb 10ft dB SPL Anechoic 3m 90243A 803 25V Blue 1 7 101 79 9 87 8 25V White 3 3 103 82 9 91 0 25V Orange 6 6 105 85 9 94 3 25V Yellow 12 7 108 88 5 96 6 70V Blue 12 4 110 88 5 96 6 70V...

Page 24: ...ed dB SPL Reverb 10ft dB SPL Anechoic 3m 90243A 804 25V Blue 3 2 106 83 3 92 1 25V White 6 3 109 86 3 95 1 25V Orange 12 9 111 89 3 97 4 25V Yellow 24 3 114 91 7 100 0 70V Blue 24 3 115 91 8 101 0 70V...

Page 25: ...our factory Do not ship the product s to us without first obtaining an RMA number Place the RMA number on all boxes returned to the factory You are responsible for transporting your product s to our...

Page 26: ...Ultra Electronics USSI 4868 East Park 30 Drive Columbia City IN 46725 USA 1 260 248 3666...

Reviews: