background image

HyperSpike

®

 LineWave Installation and Maintenance Manual 

 

 
 

 

Copyright © Ultra Electronics 

– USSI, Columbia City, IN 46725 USA

 

  90243A-MAN-LINEWAVE  Rev C 

Page 19 

3.3. 72542B-801 - Power Draw and Output SPL 

Model Number 

Input Voltage 

RMS 

Tap 

Color 

Power 

Draw, Watts 

dB SPL Max  1M, 

A-Weighted 

* dB SPL 

Reverb @ 

10ft 

* dB SPL 

Anechoic 

@ 3m 

90243A-803 

25V 

Blue 

1.7 

101 

79.9 

87.8 

25V 

White 

3.3 

103 

82.9 

91.0 

25V 

Orange 

6.6 

105 

85.9 

94.3 

25V 

Yellow 

12.7 

108 

88.5 

96.6 

70V 

Blue 

12.4 

110 

88.5 

96.6 

70V 

White 

23.9 

112 

91.2 

99.5 

70V 

Orange 

46.2 

114 

93.8 

102.0 

70V 

Yellow 

81.6 

117 

95.8 

104.0 

100V 

Blue 

23.8 

113 

91.2 

99.0 

100V 

White 

44.6 

115 

93.6 

101.0 

100V 

Orange 

83.3 

117 

96.0 

104.0 

          *UL Standard SPL Measurement 

 
 

3.4. 72542B-801 Transformer Wiring Guide 

– Used for 90243A-803 

 

 

Summary of Contents for HyperSpike LineWave 90243A-801

Page 1: ...Installation and Maintenance Manual HyperSpike LineWave ...

Page 2: ...ANGE TO ISSUE DATE WILL AFFECT RELATED LABELS WARNING EXPORT RE EXPORT AND TRANSFER OF THIS TECHNICAL DATA IS REGULATED BY US EXPORT ADMINISTRATION REGULATIONS AND MAY BE SUBJECT TO LICENSING REQUIREMENTS FROM THE BUREAU OF INDUSTRY AND SECURITY ISSUE DATE 12 16 2019 ...

Page 3: ...Transformer Recommended Hole Locations and Alignment 6 2 4 72542B 80X Circuit Breaker Reset 7 2 5 Wall Mounting 8 2 6 72544B 802 Wall Mounting Kit Installation 9 2 7 72544B 801 Wall Mounting Kit Installation 10 2 8 Pole Mounting 15 3 25V 70V 100V Power and SPL Specifications 17 3 1 72575B 801 Power Draw and Output SPL 17 3 2 72575B 801 Transformer Wiring Guide Used for 90243A 801 and 90243A 802 18...

Page 4: ...ING EXPLOSION HAZARD DO NOT DISCONNECT THE EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR UNLESS THE AREA IS KNOWN TO BE NON HAZARDOUS AVERTISSEMENT RISQUE D EXPLOSION NE DÉBRANCHEZ PAS L ÉQUIPEMENT AVANT DE L AVOIR MIS HORS TENSION OU SAUF SI LA ZONE EST CONNUE POUR ÊTRE NON DANGEREUSE WARNING WHEN MOUNTING OUTSIDE MAKE SURE THAT THE SUPPORT SYSTEM USED HAS THE PROPER WIND LOAD RATING AND COMPLI...

Page 5: ... even coverage across the listening plane while focusing the acoustic pattern away from surfaces that cause unwanted reflections This technology is essential for achieving optimum levels of speech intelligibility within reverberant spaces The result is clear and intelligible direct sound that ensures critical messages are heard and understood The LineWave is ready to be installed in either indoor ...

Page 6: ...l color options The following breakdown describes the model number configurations 90243A 80X 0X L Certification N A Uncertified L UL 1480 1480A certified Color Code 01 Black 05 Red 06 White 07 Silk Grey Speaker Configuration 801 2 Speaker 802 4 Speaker 803 8 Speaker 804 16 Speaker Note The LineWave speaker is UL 1480A certified when powered as a direct drive unit When powered with accessory transf...

Page 7: ...everb SPL 10 ft 18V Direct Drive 87 8 91 7 94 3 95 7 Anechoic SPL 3m 18V Direct Drive 93 4 98 0 103 0 104 0 Input Sensitivity 2 83Vrms 1m 85dB 91dB 97dB 103dB Nominal Impedance 16Ω 8Ω 4Ω 4Ω 2 Channel Vertical Coverage 9dB Avg 1kHz 4kHz 99 45 21 10 Frequency Response 6dB 250Hz 15kHz Required Input Signal Processing High Pass at 200Hz Direct Drive Models Only Horizontal Coverage 9dB Avg 1kHz 4kHz 18...

Page 8: ...Weight 3lbs 4 5lbs 6 5lbs 2 Installation LineWave speakers are by default configured as 4Ω 8Ω or 16Ω loudspeakers however an optional line matching transformer is available if it is desired to connect the LineWave to a Distributed Audio system LineWave loudspeakers are approved for use with 25V 70V and 100V amplifiers When configured for 25V 70V or 100V input the LineWave includes a DC blocking ca...

Page 9: ...igure 2 Wiring Diagram 90243A 804 2 2 Distributed Audio System Overview An optional 25V 70V 100V transformer allows the LineWave to be connected to 25V 70V or 100V distributed audio networks It has four field selectable power taps on the provided terminal block that allow the output SPL to be tuned to specific applications The 25V 70V 100V transformer assembly also has an integrated DC blocking ca...

Page 10: ...ve s SJOOW cable to the transformer assembly utilize the included Strain Relief Cord Connector This connector requires a 0 740 hole to be drilled in the transformer assembly Consult the following recommended hole locations before drilling Figure 3 72575B 801 Recommended Hole Locations shown in red dashed boxes Figure 4 72542B 801 and 72542B 802 Recommended Hole Locations shown in red dashed boxes ...

Page 11: ...ansformer Lid Orientation 2 4 72542B 80X Circuit Breaker Reset Transformer 72542B 80X has an integrated circuit breaker that protects itself from line surges and short circuits The circuit breaker is located inside the transformer housing near the capacitor If the breaker would trip follow the steps below 1 Remove the transformer housing lid 2 Push to reset the breaker the button on the breaker sh...

Page 12: ... Included Wall Mounting Kit 72544B 802 72544B 802 72544B 801 72544B 801 The following tables list the hardware included in the 72544B 801 and 72544B 802 wall mounting kits 72544B 801 Wall Mounting Kit 72544B 802 Wall Mounting Kit PART DESCRIPTION QUANTITY PART DESCRIPTION QUANTITY A PIVOT NUB 3 A PIVOT NUB 1 B L BRACKET 2 B L BRACKET 1 C TIE BAR 2 D 1 4 WASHER 1 D 1 4 WASHER 6 G 1 4 20 x 5 8 SCREW...

Page 13: ...for the wall according to local codes and safety practices Wall fasteners are not included in the mounting kit 2 Insert two T Nuts Part H into the slot on the back of the LineWave and attach Pivot Nub Part A using two 1 long screws Part J 3 Mount the LineWave by connecting Pivot Nub to L Bracket using flat washer Part D and 5 8 long screw Part G 4 To aim the speaker left or right loosen the 5 8 lo...

Page 14: ...ctions to install a LineWave 90243A 801 or 90243A 802 on a wall surface 1 Fasten two L Brackets Part B to the wall surface using appropriate fasteners for the wall Always follow local codes and safety practices Wall fasteners are not included in the mounting kit a 90243A 803 L Bracket recommended spacing is 20 apart b 90243A 804 L Bracket recommended spacing is 43 apart Figure 8 90243A 803 and 902...

Page 15: ... two Tie Bars Part C to Pivot Nub Part A using two flat washers Part D 1 5 8 long screw Part E and lock nut Part F as shown in Figure 9 Figure 9 90243A 803 and 90243A 804 Wall Mounting Step 2 3 Attach Pivot Nub Assembly from Step 2 to the top L Bracket using flat washer Part D and 5 8 long screw Part G Figure 10 90243A 803 and 90243A 804 Wall Mounting Step 3 ...

Page 16: ...SA 90243A MAN LINEWAVE Rev C Page 12 4 Insert four T Nuts Part H into the slot on the back of the LineWave and attach two Pivot Nubs Part A 1 from each end using four 1 long screws Part J On the bottom Pivot Nub install set screw Part K as shown in Figure 11 Figure 11 90243A 803 and 90243A 804 Wall Mounting Step 4 ...

Page 17: ... LineWave fasten the top Pivot Nub to the Tie Bars from step 1 using 1 5 8 Long Screw Part E two Flat Washers Part D and Lock Nut Part F Figure 12 90243A 803 and 90243A 804 Wall Mounting Step 5 6 To aim the speaker left or right loosen the top screw and pivot the unit to the desired position as shown in Figure 13 Once the speaker is in the appropriate position retighten screw Pan angle is adjustab...

Page 18: ...neWave Slide the Pivot Nub up and down to adjust the tilt angle to the desired orientation as shown in Figure 14 The LineWave may need to be temporarily rotated left or right in order to access the screws Figure 14 90243A 803 and 90243A 804 Wall Mounting Step 7 8 Once the desired orientation is achieved tighten all fasteners Install flat washer Part D and lock nut Part F onto bottom set screw Figu...

Page 19: ... available for LineWave models 90243A 803 and 90243A 804 which allows mounting to poles ranging from 3 7 in diameter This kit is used in conjunction with the wall mounting hardware supplied with the speaker unit The following table lists the hardware included in the 72581B 801 Pole Mount Kit 72581B 801 Pole Mounting Kit PART DESCRIPTION QUANTITY D 1 4 WASHER 8 F 1 4 20 LOCK NUT 4 L POLE MOUNT BRAC...

Page 20: ...racket Part L using two flat washers Part D two lock nuts Part F and two 1 long screws Part J Repeat process with second bracket Figure 16 72581B 801 Pole Mounting Step 1 2 Fasten the Pole Mount Bracket assembly to pole using straps Part M a 90243A 803 L Bracket recommended spacing is 20 apart b 90243A 804 L Bracket recommended spacing is 43 apart Figure 17 72581B 801 Pole Mounting Step 2 3 Procee...

Page 21: ...r Draw Watts dB SPL Max 1M A Weighted dB SPL Reverb 10ft dB SPL Anechoic 3m 90243A 801 25V Blue 0 5 86 72 4 78 2 25V Orange 1 3 91 77 1 82 2 25V Red 1 6 92 78 2 83 8 25V Brown 2 7 94 79 9 85 3 70V Blue 3 0 95 80 8 86 3 70V Orange 8 3 100 84 9 90 7 70V Red 10 7 101 85 9 91 9 70V Brown 15 3 103 87 2 92 7 100V Blue 5 7 98 83 5 89 1 100V Orange 15 3 103 87 1 92 9 100V Red 19 5 104 88 0 93 8 90243A 802...

Page 22: ...LineWave Installation and Maintenance Manual Copyright Ultra Electronics USSI Columbia City IN 46725 USA 90243A MAN LINEWAVE Rev C Page 18 3 2 72575B 801 Transformer Wiring Guide Used for 90243A 801 and 90243A 802 ...

Page 23: ...ighted dB SPL Reverb 10ft dB SPL Anechoic 3m 90243A 803 25V Blue 1 7 101 79 9 87 8 25V White 3 3 103 82 9 91 0 25V Orange 6 6 105 85 9 94 3 25V Yellow 12 7 108 88 5 96 6 70V Blue 12 4 110 88 5 96 6 70V White 23 9 112 91 2 99 5 70V Orange 46 2 114 93 8 102 0 70V Yellow 81 6 117 95 8 104 0 100V Blue 23 8 113 91 2 99 0 100V White 44 6 115 93 6 101 0 100V Orange 83 3 117 96 0 104 0 UL Standard SPL Mea...

Page 24: ...ted dB SPL Reverb 10ft dB SPL Anechoic 3m 90243A 804 25V Blue 3 2 106 83 3 92 1 25V White 6 3 109 86 3 95 1 25V Orange 12 9 111 89 3 97 4 25V Yellow 24 3 114 91 7 100 0 70V Blue 24 3 115 91 8 101 0 70V White 46 6 118 94 4 103 0 70V Orange 90 6 120 96 8 105 0 70V Yellow 159 3 123 98 4 106 0 100V Blue 47 8 118 94 5 103 0 100V White 89 1 121 96 8 105 0 100V Orange 165 8 123 98 7 107 0 UL Standard SPL...

Page 25: ...o our factory Do not ship the product s to us without first obtaining an RMA number Place the RMA number on all boxes returned to the factory You are responsible for transporting your product s to our factory We will pay the return shipping charges on all product s repaired under warranty Failures Not Covered by This Warranty This warranty covers defects in manufacture only It does not cover 1 dam...

Page 26: ...Ultra Electronics USSI 4868 East Park 30 Drive Columbia City IN 46725 USA 1 260 248 3666 ...

Reviews: