Ultra-Aire SD12 Installation Instructions
www.Ultra-Aire.com | (800) 533-7533
www.Ultra-Aire.com | (800) 533-7533
Ultra-Aire SD12 Installation Instructions
DUCTING TO HVAC SYSTEMS
Alternative HVAC System Installations
If the Recommended Dedicated Ultra-Aire Return to HVAC Supply Installation is not possible, there are several
alternative installation options available.
• DO NOT locate return in a bathroom or kitchen.
• Control should be located remotely from the dehumidifier and placed in a central location.
Dedicated Ultra-Aire Return to HVAC Return
Outdoor
Condensing
Unit
Air Handler
HVAC Supply
Dedicated Ultra-Aire 90 Return to A/C Retur
n
HVAC
Return
Fresh Air Intake
(Optional)
Motorized
Damper
Indoor
Air Return
Ultra-Aire
Supply
Create a separate return for the Ultra-Aire
SD12 in a central area of the building.
Installing the supply air from the Ultra-Aire
SD12 in the return of the HVAC system
requires the HVAC fan to run when the
Ultra-Aire SD12 is operating.
HVAC Return to HVAC Supply
Outdoor
Condensing
Unit
A/C Return to A/C Supply
Air Handler
HVAC Supply
HVAC
Return
Backdraft
Damper
Optional Check Damper
(no HVAC fan needed)
Fresh Air
Intake
(Optional)
Motorized
Damper
Ultra-Aire Supply
Check Damper should be in place between
the Return and Supply connections of the
dehumidifier.
If Check Damper is not in place, the HVAC
fan must turn on when the dehumidifier
is in operation.
HVAC Return to HVAC Return
Air Handler
HVAC
Supply
A/C Return to A/C Return
HVAC Return
Fresh Air
Intake
(Optional)
Motorized
Damper
Optional Check Damper
(no HVAC fan needed)
Ultra-Aire
Supply
Outdoor
Condensing
Unit
Check Damper should be in place between
the Return and Supply connections of the
dehumidifier.
If Check Damper is not in place, the HVAC
fan must turn on when the dehumidifier is
in operation.