![background image](http://html.mh-extra.com/html/ultra-aire/70h/70h_installation-instructions-manual_836875006.webp)
6
Ultra-Aire 70H Installation Instructions
www.Ultra-Aire.com | 1-800-533-7533
Important Precautions
• The device is designed to be installed indoors in a space that is protected from rain and flooding.
• Install the unit with enough space to access all sides for maintenance and service. The entire shell needs to be
removed in order to do repairs.
• Avoid directing the discharge air at people. The dehumidifier should be used in the upright position.
• If used near a water source; be certain there is no chance the unit could fall into the water or get splashed and
that it is plugged into a dedicated circuit and Ground Fault Circuit Interrupter (GFCI) protected outlet.
• DO NOT use the dehumidifier as a bench or table.
• DO NOT place the dehumidifier directly on structural building members without vibration absorbers or unwanted
noise may result. Place the Ultra-Aire 70H on supports to raise the base of the unit.
• A drain pan MUST be placed under the dehumidifier if installed above a living area or above an area where
water leakage could cause damage.
Location Considerations
• Allow sufficient clearance to handle the unit’s overall dimensions as well as the necessary return and supply
ductwork to the unit.
• Allow sufficient clearance for filter removal and to prevent airflow obstruction.
• Electrical service access will require the removal of the outside shell. Allow sufficient clearance around the unit.
• Locate the dehumidifier in an area where the cord’s lenght (9') easily reaches a 115 VAC electrical outlet with a
minimum of a 15 Amp circuit capacity.
• Locate the dehumidifier in an area where field wiring the control (low voltage) to the unit will be possible.
• It is recommended that a
backdraft damper be used in
the discharge duct of the
Ultra-Aire 70H, especially
when connecting to the supply
ducting system. The backdraft
damper prevents supply air
from counter flowing through
the Ultra-Aire 70H when it is
not operating. The dehumidifi-
er’s location should be chosen
to allow installation of this
accessory if necessary.
• The Ultra-Aire 70H may be
suspended with the hang kit
or a suitable alternative from
structural members,
ensuring the assembly
supports the dehumidifier’s
base in its entirety. DO NOT
hang the Ultra-Aire 70H from
its’ cabinet.
• Allow for proper drainage and
routing of needed drain pipes.
ELECTRICAL SERVICE
ACCESS THIS SIDE
6" MINIMUM CLEARANCE
FOR PROPER AIR FLOW
FILTER
9' POWER CORD
TOP VIEW
MINIMUM
CLEARANCE
FOR FILTER
(EITHER SIDE)
13"
B
B
RETURN AIR DUCT
SUPPLY AIR DUCT
A
B
C
A
DRAIN
ACCESS
DEHUMIDIFIER SET UP
Summary of Contents for 70H