ULGD 5.0 A1
■
6
│
GB
│
IE
│
NI
│
CY
Program 2
„12 V“ (14,4 V / 0,8 A)
For charging 12 V batteries with a capacity of less
than 14 Ah .
♦
Press the program selection button , to select
program 2 . The symbol
is displayed on the
LCD . During charging, the charge display
flashes and shows the progress of the charge
procedure (1–4 bars) . When the battery is fully
charged, the condition display shows 4 bars .
The flashing stops and the appliance automati-
cally switches to retention charge .
Program 3
„12 V“ (14,4 V / 5,0
A)
For charging 12 V batteries with a capacity of
between 14 Ah–120 Ah .
♦
Press the program selection button , to select
program 3 . The symbol
is displayed on
the LCD . During charging, the charge display
flashes and shows the progress of the
charge procedure (1–4 bars) . When the bat-
tery is fully charged, the condition display
shows 4 bars . The flashing stops and the appli-
ance automatically switches to retention charge .
Program 4 „12 V“ (14,7 V / 5,0 A)
For charging 12 V batteries with a capacity of
between 14 Ah–120 Ah under cold conditions or
for charging AGM batteries .
♦
Press the program selection button , to select
program 4 .
NOTE
►
This program may start with a minute delay .
The symbol
is displayed on the LCD .
During charging, the charge display
flashes and shows the progress of the charge
procedure (1–4 bars) . When the battery is
fully charged, the condition display shows
4 bars . The flashing stops and the appliance
automatically switches to retention charge .
Retention charge
As described under programmes, this appliance
features the automatic retention charge . Depending
on the voltage drop of the battery, caused by
selfdischarge, the appliance reacts with different
charge currents .
The battery can remain connected to the charger
for longer periods of time .
Appliance protection function
The charger switches the electronics off and
switches the system instantly to the basic setting,
as soon as there is an abnormal situation, such as
short circuit, critical voltage drop during charging,
broken circuit or swapped connection of the con-
nector clamps is detected .
Should the appliance become too hot during
charging, the output current is automatically re-
duced . This protects the appliance from damage .
Maintenance and care
WARNING! Before you carry out any
work on the battery charger always pull
the mains plug out of the mains socket.
The appliance is maintenance-free .
♦
Do not under any circumstances use solvents or
other aggressive cleaning agents .
♦
Clean the plastic surfaces of the device with a