Diversi-foam II 

Hybrid Mattress

Quick Reference Guide

This Quick Reference Guide (QRG) has been produced to assist users with only the functional aspects of the 

system. Please refer to the User Manual for full instructions for use.

Power

 

Touch the Power button to turn the power unit

ON and OFF.

The panel must be unlocked before the pump

Control Panel Lock

 

In order to unlock the control panel, simply

touch and hold the Lock button for 3 seconds, the

control panel will now be active for use.
If the control panel is not used for a period of 40 

seconds it will lock out and inhibit the use of the 

functions.

Pressure up/down (Comfort Control)

 

When touching the + button, the output pressure 

will increase to provide a higher pressure output 

and thus increased support.

When touching the - button, the output pressure

will be decreased to provide a lower pressure

output and thus increased comfort.

Weight / Pressure Display

When switched ON this display will give constant

feedback of pressure (mmHg) within the cells.

When adjusting the Comfort Control (see

Pressure up/down) the panel will temporarily

display the weight setting before returning to

pressure reading.

Alternating / CLP Therapy Modes

Alternating mode is the default setting for the

system. Within this mode the mattress will operate

in an alternating 1-in-2 cell cycle. The 10 minute

alternating cycle will continue unless the CLP

mode is selected.

Activating the CLP puts the system into Constant

Low Pressure (CLP) mode, this mode is static at

20mmhg.

Alarm

 

The alarm mute button temporarily resets the

audible Low Pressure/Power Failure/Service

alarms.

to alarm even when not connected to a power

source. (See Power and Control Panel Lock)

Low and Normal Pressure Indicator

Once the system is ready the Normal and Low

pressure alarm will be illuminated (GREEN)

temporarily during the cycle or if comfort levels

have been adjusted.

Upon detection of low pressure, an audible

alarm will sound and the Low Pressure indicator

will illuminate (RED). The audible alarm may be

cancelled by touching the Alarm Mute button

(see Alarm button) . The Low Pressure indicator

will continuously illuminate (RED) until the low

pressure fault condition is resolved.

Use the + and – buttons to set the patient 

weight in kg. 

Please refer to user manual for guidance

www.ultimatehealthcare.co.uk  |  Tel: 0333 321 8996

Constant low 

pressure

CLP

w w w . u l t i m a t e h e a l t h c a r e . c o . u k 