4.  Align the hinges with the mounting bracket and 

drop the cover into place

3.  From the front of the printer, place the cover 

over the fi lter housing

Reassemble the Air Manager

5.  Connect the Air Manager cable to the port at the 

back of the Air Manager

Tip:

 The hinge must be fl ush with the mounting bracket. If necessary, 

slightly press down on the hinge until you hear it click into place.

Note:

 The fl at side of the connector faces towards the printer. 

2.  Gently push the fi lter completely into 

the fi lter housing 

 

Note:

 Make sure the fi lter is completely fl ush in the housing

1.   Align the bottom of the fi lter housing 

with the slots in the mounting bracket 

and push it into place

6.  Secure the Air Manager cable with 

the stress relief clip

Note:

  

The cable must be fully inserted and held in place with the clip 

to ensure the most reliable connection.