5
Ultimaker S5 Air Manager
Repair manual: Air Manager fan
Ultimaker Customer Service instructions
4. Align the hinges with the mounting bracket and
drop the cover into place
3. From the front of the printer, place the cover
over the fi lter housing
Reassemble the Air Manager
5. Connect the Air Manager cable to the port at the
back of the Air Manager
Tip:
The hinge must be fl ush with the mounting bracket. If necessary,
slightly press down on the hinge until you hear it click into place.
Note:
The fl at side of the connector faces towards the printer.
2. Gently push the fi lter completely into
the fi lter housing
Note:
Make sure the fi lter is completely fl ush in the housing
1. Align the bottom of the fi lter housing
with the slots in the mounting bracket
and push it into place
6. Secure the Air Manager cable with
the stress relief clip
Note:
The cable must be fully inserted and held in place with the clip
to ensure the most reliable connection.
Finished! You can now power on the Ultimaker S5 again.