CAUTION! After completing the ozone treatment, ventilate the room for
15 to 30 minutes or do not enter the room earlier than 2 hours after completing
the ozone treatment.
CAUTION! Use the unit only in empty rooms! Ozone is an irritant gas and
damages biological membranes by radical reactions with their components.
If you still smell the ozone after you have entered the room, first make sure
that the unit is switched off and then leave the room and/or ventilate it.
3.4.
Cleaning and maintenance
a)
Pull out the mains plug before each cleaning and when the unit is not in use.
b)
Use only non-corrosive cleaning agents for cleaning the surfaces.
c)
Store the unit in a dry and cool place protected from moisture and direct
sunlight.
d)
Do not spray the unit with a stream of water or immerse it in water.
e)
Make sure that no water enters through the ventilation openings in the casing.
f)
Perform regular inspections of the unit checking technical fitness and any
damages.
g)
Use a soft, damp cloth for cleaning.
h)
The ozone plates should be cleaned once a month.
i)
To ensure effective use of the equipment replacing the ozone plates every 6
months is recommended.
REPLACING THE OZONE PLATE
1.
Loosen the handle and pull out the ozone plate.
2.
Clean the ozone plate with water or replace with a new one.
3.
Before installing, make sure the plate is dry and the metal ends make good
contact.