ULFIA Elektronik AB
24-0025-3201-64
CMT-2 Test box
2003-04-21 U.A.
rev. 1
page 12 of 14
8
Signals to CMV-indicator from processor SUPPLY/INSTRUMENT-
connector :
Wait 5 s and then switch to CMV 150(20%).
With
FREQ. CORR. OFF
( rotary switch position =1 ) selected on the processor
and any frequency selected on the CMT-2 test box :
CMT-2
CMT-2 and
CMV-indicator
Calibrator
CMV
position
Boun-
cing
button
CMV-
range
button
DMM
reading =
Vdc
CMV-
indicator
reading on
0-150 scale
(0-50 scale)
Boun-
cing
indicator
CMV-
range
indicator
150 (20%)
OFF
OFF
+4.8 -- +5.2
145 - 155
OFF
OFF
“
ON
OFF
+4.8 -- +5.2
145 - 155
ON
OFF
100 (16%)
ON
OFF
+3.2 -- +3,5
95 - 105
OFF
OFF
“
OFF
OFF
+3.2 -- +3,5
95 - 105
OFF
OFF
50
OFF
OFF
+1.5 -- +1.73
45 - 55
OFF
OFF
“
OFF
ON
+4.8 -- +5.2
(48 - 52)
OFF
ON
0
OFF
OFF
-0.1 -- +0.1
0 - 5
OFF
OFF
With frequency correction selected on the processor :
Frequency selected on
calibrator
FREQ. CORR. rotary switch
on processor
rpm
= Hz
position
1500
25
2
1700
28.3
3
2000
33.3
6
2500
41.7
8
3000
50
10
1500-3000
25 - 50
1 (frequency correction off)
CMT-2 Calibrator
CMV position
DMM reading = Vdc
CMV reading on
instrument
150
+4.7 -- +5.3
142 - 158
100
+3.1 -- +3,6
93 - 107
50
+1.45 -- +1.75
4 - 55
0
-0.1 -- +0.1
0 - 5
Using the test box,
continued
Summary of Contents for CMT-2