background image

 

4. Sensor wiring example 

4.1 Thermocouple sensor wiring (only K-type) 

- Default port number is 1,2 (No.1 + No.2 –) 
- If not connected, the temperature is 1000℃ 
- You wind the sensor cable 2~3 times to the ferrite core for data reliability and 

electromagnetic shielding. 

 

 

Figure 1 Thermocouple wiring 

 
4.2 Analog input wiring ( volt, current, resistance ) 

- Default port number is 1,2 
- Power supply No.3(GND), No.5(+24V), No.6(+5V) 
- You wind the sensor cable 2~3 times to the ferrite core for data reliability and electromagnetic 

shielding. 

 

> Example. Voltage output Sensor

 ( 

MM2001 Humidity

 Red:+5V, Black:GND, Yellow:Signal )

  

 

 

Figure 2 Voltage output sensor Example 

 

 

Summary of Contents for WFS-205BW

Page 1: ...1 WICON WFS 205BW IIoT WiFi Gateway USER MANUAL FCC ID 2AO6A WFS 205BW ...

Page 2: ...limits set forth for an uncontrolled envi ronment This equipment should be installed and operated with minimum distance 20cm be tween the radiator and your body This transmitter must not be co located or operating in con junction with any other antenna or transmitter ...

Page 3: ...m 6 3 Device detail description 7 3 1 Power port 7 3 1 LED 7 3 3 Reset button 8 3 4 Sensor connector 8 4 Sensor wiring example 9 4 1 Thermocouple sensor wiring only K type 9 4 2 Analog input wiring volt current resistance 9 4 3 Digital input wiring 10 5 WICON Setting 12 5 1 Wicon manager download 12 5 2 Search device 12 5 3 Serial number 13 5 4 Device information 13 5 5 View Wim X 14 ...

Page 4: ...nsists of three modules Bluetooth module for setting WiFi module for transmission Sensor connection module for sensor The device supports four types of analog input and three types of digital input Thermocouple volt current resistance NPN PNP dry contact Compared to other company devices it is compact and easy to install Settings can be made using a smartphone The magnet mounted cradle will make i...

Page 5: ...Chip antenna 1 9dBi 1 3 Sensor input specification 1 4 Device order number example You should check the order number when ordering the product WFS 205DS KKKK thermocouple total 4ch WFS 205DS VXXX analog volt input total 1ch WFS 205DS VCDX analog volt currnet input digital input total 3ch Input Type Measurement Range Remark Order Number Analog Thermocouple K type 0 1000 2 Accuracy Range 0 250 withi...

Page 6: ...se the cradle when using the product 2 2 Size unit mm Sensor wiring connector Plug type WFS 205BW BLE for setting WFS 205DS Sensor Connectino Module Cradle that can be attached to metal Power connector USB Micro 5pin WFS 205BW WiFi for communication 77 2 121 2 50 ...

Page 7: ... attempt 250msec Light on AP connection completed Slow Blink AP connection Fail 1sec Very Slow Blink Server connection Fail 10sec LED status afer power on Normal setting status WFS 205BW BLE WiFi RED LED on WFS 205BW WiFi RED LED fast blink 250msec WFS 205BW WiFi RED LED light on WFS 205BW WiFi BLUE ELD blink every 1sec Blinking BLUE when sampling Light on RED when power on See table below Blinkin...

Page 8: ...e initialization 3 4 Sensor connector No 1 and No 2 are default But There are differences between sensor types Table 2 Connector pin map NO TH K AI V AI C AI O DI D 1 Thermocouple Volt 0 10V Current 0 20mA Register DC 12 24V 2 Thermocouple GND GND GND DC 3 GND GND GND GND GND 4 Reserved Reserved Reserved Reserved Reserved 5 24V 24V 24V 24V 24V 6 5V 5V 5V 5V 5V ...

Page 9: ...ta reliability and electromagnetic shielding Figure 1 Thermocouple wiring 4 2 Analog input wiring volt current resistance Default port number is 1 2 Power supply No 3 GND No 5 24V No 6 5V You wind the sensor cable 2 3 times to the ferrite core for data reliability and electromagnetic shielding Example Voltage output Sensor MM2001 Humidity Red 5V Black GND Yellow Signal Figure 2 Voltage output sens...

Page 10: ...wire RTD but if you want to use it short the calibration line and use it Figure 4 Resistance output sensor 4 3 Digital input wiring Depends on type NPN PNP You wind the sensor cable 2 3 times to the ferrite core for data reliability and electromagnetic shielding Example NPN Proximity sensor Brown 24 Blue GND Black Signal Figure 5 NPN sensor Need for wiring 1 5 ...

Page 11: ...ple PNP Proximity sensor Brown 24 Blue GND Black Signal Figure 6 PNP sensor Need for wiring 2 3 Example Dry contact General purpose relay contact Figure 7 General purpose relay Need for wiring 2 3 Realy Power ...

Page 12: ...er Membership required Note Wi Fi data transfer cloud server transfer is not performed when wicon is in configuration mode during operation 5 1 Wicon manager download 5 2 Search device Connect the power of the product run Wicon manager and select WF 000000 If you can not find WF 000000 press the search button ...

Page 13: ... If the smartphone and the BLE module are connected the following screen will be displayed Led of WiFi module alternately blinks blue and red Enter the SSID password and sensor type and then click B In normal cases the LED will flash quickly and then reset If the reset does not work or the screen seems to be frozen start from 5 2 again Connection Fail Attempt to reconnect ...