UL GenerLink Operating Manual Download Page 9

STEP 4.

Turn off the idle setting (if present) on your generator. This will ensure

that your generator will operate at the correct speed and voltage.

STEP 5.

Review the generator starting procedures in the generator owner’s

manual and then start your generator.

STEP 6.

If after starting your generator, the GenerLink

unit begins emitting a 

constant audible alarm, IT IS STILL SAFE TO OPERATE YOUR
GENERATOR with GenerLink

. The alarm indicates that the surge

protection components may require service. (See Warranty and Service
Section in this manual) 

STEP 7.

Select the appliances that require emergency power. Note the capacity

of your generator and refer to the Appliance Energy Guide in this manual. 

Locate the circuit breakers in your home’s breaker panel (See Diagram 4) for
the appliances you can support
and turn them on one at a time.
Start with large motor loads
first, such as refrigerators.
Motors require 2 to 3 times
more power to start than other
electrical appliances. Allow gen-
erator operation to stabilize
before starting the next load. Next, start smaller motors such as a ceiling or
ventilating fan. Then start smaller appliances with no motors such as lights.

STEP 8.

When it is time to refuel your generator, turn off all your home’s   

circuit breakers before turning off the generator, and refuel according to your
generator owner’s manual. Then begin with Step 1 of the Start-Up Procedure
to reconnect loads/appliances.

5

Q. I have meter-based surge protection, but want GenerLink

. Should

I get hard-wired surge protection?

A. If your GenerLink

unit is equipped with whole house surge protection it

will eliminate the need for meter based or hard wired surge protection devices.

Q. Why can’t I run my whole house from a portable generator?

A. The appliances in the average home consume relatively low amounts of
electricity to operate once they are started. However, many of them require a
significant amount of electricity to start up the appliances. Please review the
appliance guide to determine the start-up wattage required for individual
appliances.

Q. What happens when the utility power is restored and my generator
is operating through GenerLink

?

A. Your generator continues to power your home until you turn it off. Once
you turn off your generator, GenerLink

will automatically switch your home

back to utility power. GenerLink

has a built-in safety feature that prevents

back feeding the generator’s power into the utility lines, eliminating hazardous
conditions for you and for utility service personnel.

Q. Does my utility meter continue to run when using GenerLink

with my generator?

A. No, your utility meter will only run when the utility is providing electric
power to your home. When using GenerLink

, with your portable generator,

you are automatically disconnected from the utility power supply and will not
reconnect until you turn off your generator.

Q. How can I tell when the utility power is restored?

A. There are four indicator lights on GenerLink

, one blue, one green, one

yellow, and one red. When the blue light is illuminated, you are connected to
your generator. When the green light is illuminated, this represents a 
normal condition where utility power is present. When your utility has restored
power, you can de-energize and disconnect your generator from GenerLink

. If

the red light is illuminated at any time or in conjunction with the green light,
there is a potential problem, and you should have the unit 
serviced immediately. (Refer to the Terms and Conditions for service 
instructions)

Q. Can I use GenerLink

during inclement weather?

A. GenerLink

is completely sealed inside the meter socket and does not

represent a hazard; however, generators should not be operated during rain or
snow unless they are protected from the elements. Please consult your generator
manufacturer, distributor and/or owner’s manual for instructions on the safe
operation of your generator. 

Diagram 4

Breaker Panel

!

WARNING

Before refueling your generator, consult the

manufacturer’s instructions as found in the

generator owner’s manual.

20

Summary of Contents for GenerLink

Page 1: ...erlink com MA23 S unit with whole house surge suppression Operating Manual Generlink 225 Arnold Road Lawrenceville GA 30044 www generlink com OPER MA23S FPLES 1 2021 Please refer to page 22 for GenerLink testing while utility power is present ...

Page 2: ...roduced or transmitted in any form or by any means electronic or mechanical including photocopying recording or by an information storage or retrieval system without the prior written permission of Global Power Products Inc unless such copying is expressly permitted by federal copyright law Address inquiries to Generlink 225 Arnold Road Lawrenceville GA 30044 27 i ...

Page 3: ...th limited appliance availability Utility s Electric Distribution System A network of power lines and associated equipment used to transmit and distribute electricity over a geographic area Voltage Electrical potential or force that causes current to flow through a conductor Watt A unit that measures the amount of electrical power watts volts x amps 26 ii ...

Page 4: ... designed to display power condi tions with the GenerLink unit utility and the portable generator Start up Wattage The amount of energy needed to first start an appliance This amount is usually larger than the running wattage for appliances with motors refrigerator It is usually the same for appliances without motors lights Sub Panel Device used in connection with a transfer switch designed to byp...

Page 5: ...rcurrent device Generator A machine that converts mechanical energy into electrical energy GenerLink A five inch collar like device installed behind your electric meter which allows you to easily and safely connect a portable generator to your home s existing wiring system GenerLok GenerLok is a unique fitted locking connector exclusively available for GenerLink Setup Procedures Setup Procedures C...

Page 6: ...Link yourself Refer to Terms and Conditions for service instructions Red Status Light Red Status Light The red status light indicates an abnormal condition exists and GenerLink s safety circuits were initiated Illumination of the red status light does not indicate an unsafe condition exists It is normal for the red status light to momentarily illuminate when GenerLink cycles between generator and ...

Page 7: ...by turning off ALL the circuit breakers in the house 3 Confirm that the yellow status light is not illuminated 4 Reconnect and restart the generator 5 Restore load equal to or less than the capacity of generator 6 Operate household loads using your generator 7 Do not under any conditions attempt to remove or repair GenerLink yourself Problem GenerLink will not continuously connect the generator to...

Page 8: ...he power cord should be as close to the actual measured distance from the meter to the generator as possible in order to maintain your generator s power quality Q What if my generator connector does not have a straight or locking L14 30 connector A Some generators are fitted with connectors that are not L14 30 Consult with your local utility or a GenerLink Authorized Reseller to determine if your ...

Page 9: ...ricity to start up the appliances Please review the appliance guide to determine the start up wattage required for individual appliances Q What happens when the utility power is restored and my generator is operating through GenerLink A Your generator continues to power your home until you turn it off Once you turn off your generator GenerLink will automatically switch your home back to utility po...

Page 10: ...ntages over traditional transfer switches GenerLink is installed outside your home at the electric meter in less than 20 minutes And in most cases you do not need to be at home for the GenerLink installation Installation of a transfer switch can take about two to three hours and requires re wiring your home s electric system With GenerLink you have the flexibility of selecting the appliances you w...

Page 11: ...ome generators are rated for only 120 volt or only 240 volt output neither are appropriate for powering your home through GenerLink If your generator does not have a 120 240 volt AC receptacle it is not suitable for use with GenerLink Check your generator for one of the receptacles in Diagram 6 These receptacles are rated for 120 240 volt output which is what you need to run your home If your gene...

Page 12: ...8 17 T Technical Fact Sheet echnical Fact Sheet GenerLink Specifications and Technical Information Physical Diameter 6 in Depth 5 in Weight w o surge 5 lbs Weight with surge 5 lbs Socket Style Ring or Ring less 200 Amp 4 jaw Electrical Source Compatibility 200 Ampere Service or Less Withstand Current 8 000 Amperes rms symmetrical at 5 pf 240 Volts 60 Hz 6000 Amperes for 6 cycles at 7 8 pf 240 Volt...

Page 13: ... by power strips Plus it provides enhanced protection for household electronics Provides protection beyond typical point of use power strips and plug ins Produces an audible alarm when the devices requires service Protects against spikes up to 100 000 amps on the electric system Provides a white goods warranty of 1 000 appliance and or 10 000 house Is meter based and will provide the first line of...

Page 14: ...d check the cord for exposed wires and or frayed insulation Keep the power cord stored in a dry safe location when not in use Ensure that the GenerLok power cord is in a protected area where it will not be damaged by lawn mowers power tools or vehicles Never attempt to remove repair dismantle modify or alter GenerLink once it has been installed CAUTION Always locate and operate your generator in a...

Page 15: ...tor Selecting a Portable Generator What Kind of Generator Do I Need There are a wide variety of portable generators available for purchase Some are more suitable than others for connecting to your house When selecting a portable generator to connect to your house you should ensure the generator will not damage sensitive electronic appliances equipment provides the capacity to start needed motor lo...

Page 16: ... amps GenerLink is designed to be compatible with 20 amp or 30 amp connectors GenerLink is not rated to be compatible with larger current out puts and will electronically disconnect if you are generating outputs larger than 40 amps Appliance Usage Guide Appliance Usage Guide Equipment Water Heater 50 gallon Portable Heater with fan Furnace Fan Central 1 4 HP 1 3 HP 1 2 HP Computer Fax Machine Spac...

Page 17: ......

Reviews: