background image

2.

 

Before filling the filter vessel with the filter media, install the laterals, this has to be done 

from inside the tank as the assembly cannot be built outside of the filter. simply match the 

raised point at the end of each lateral (see fig 2.) to the raised point on the lateral hub.  

Insert the laterals and turn 90

°

 clockwise, you should hear the lateral click into place. Repeat 

until all laterals are fitted. 

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

              Fig. 2 

 

 

3.

 

 Check the air release hose is fixed securely onto the body of the lateral holder with the 

other end out of the sand – 

DO NOT

 bury the air release hose in the sand, it must be free to 

sit on top of the final filled level. 

4.

 

To eliminate stress during the sand filling on the laterals, fill the filter vessel with enough 

water to provide a cushioning effect when the filter sand is poured in (12”). 

5.

 

In the packaging you will find a flimsy clear sand filling ‘Top Hat’. This is vital in ensuring the 

filters internal pipe is perfectly located & central before filling with sand. The ‘Top Hat’ will 

prevent any sand from dropping into the centre pipe, it is a clear indication that the centre 

pipe is fully down into the filter. 

6.

 

Carefully pour the sand into the filter vessel. Ensure that no sand enters the stem pipe and 

that no damage occurs to the laterals. Continue filling the filter until the correct charge has 

been installed (see chart for sand fill charges). 

7.

 

Remove the ‘Top Hat’ and wash any debris off the filter top mount, put the O Ring on the 

top mount multiport valve and with a twisting pushing action fit the valve onto the filter 

centre pipe until fully home. Assemble to two half flanges together to connect the filters top 

lid and multiport flanges within the clamp and lightly tighten equally. 

Do not

 fully tighten 

until you are satisfied that the multiport is in the correct alignment to ensure a straight 

connection to the pump.  

8.

 

Using screws from the pump hardware pack fix the pump to the base.  Please refer to pump 

installation guide for operating instructions. 

9.

 

Adjust the valve position and using the white pressure hose(ensuring you fit the ‘O’ rings), 

connect the pump output to the top mount valve. (“

TO PUMP

” is embossed on the curved 

plastic input of the multi port valve to easily identify the correct port). 

10.

 

There are two remaining connections to the valve – one is connected to the pool (marked 

TO POOL

”) the other connects to the drain outlet hose, which is also easily identified with 

the sight glass. 

 

 

 

Summary of Contents for UKPS16

Page 1: ...are designed to work with water at temperatures above 0 C and below 45 C The filter should never be operated outside of these temperatures or damage may occur 2 The installation should be carried out in accordance with the safety instructions for swimming pools and the specific instructions for each facility 3 The user must ensure sure that the installation is carried out by qualified authorised p...

Page 2: ...t Valve and back through the swimming pool piping system Preparation before installation 1 Position the filter as close to the Swimming Pool Spa as possible 2 The filter should be placed on a level concrete slab very firm ground or the equivalent Ensure that the ground will not subside preventing any strain on the attached plumbing 3 Position the filter so that it does not compromise the piping co...

Page 3: ...into the filter 6 Carefully pour the sand into the filter vessel Ensure that no sand enters the stem pipe and that no damage occurs to the laterals Continue filling the filter until the correct charge has been installed see chart for sand fill charges 7 Remove the Top Hat and wash any debris off the filter top mount put the O Ring on the top mount multiport valve and with a twisting pushing action...

Page 4: ... impurities and fine sand particles evident in the filter media 6 Turn pump OFF and set valve to RINSE position Turn pump ON and run until the water in sight glass is clear about to 1 minute Turn pump OFF set valve to FILTER position and restart pump Your filter is now operating in the normal filter mode filtering particles from the pool water and returning fresh clean water back into your pool NO...

Page 5: ...E Rinse RINSE After backwashing and with pump OFF set valve to RINSE Start pump and operate for about to 1 minute This ensures that all dirty water from backwashing is rinsed out of the filter to waste preventing possible return to the pool Stop pump set valve to FILTER and start pump for normal filtering Waste WASTE To bypass the sand filter for draining or lowering water level and for vacuuming ...

Page 6: ...ufacturer or its service agent or a similarly qualified person 10 The pump must be supplied through a residual current device RCD having a rated residual operating current not exceeding 30mA 11 Children should be supervised to ensure that they do not play with the appliance 12 The pump must be protected from running dry LOCATION The pump must be located as close as is practical to the pool The pum...

Page 7: ...mp to re prime If this fails then simply repeat the priming procedure WARNING Mechanical seals will be rapidly damaged and may need replacing if the pump is run dry this is not a warranty condition ENSURE that there is always adequate water in the pump basket before you start up If you are unable to prime the pump please see the trouble shooting guide ENSURE that all suction and discharge valves a...

Page 8: ...tem clean lines skimmer and pump basket check pump impeller for blockage Motor will not run No power to motor Check that all electrical switches are on Ensure the circuit breakers are properly set Check if timer is properly set Check motor wiring at the terminals Pump jammed With power switched off turn pump shaft should spin freely Low Flow Dirty Filter Backwash or clean cartridge Dirty skimmer a...

Page 9: ... at motors should be no more than 6 above or below nameplate voltage Have electrician check voltage ensure pump is not running on an extension cord Report low supply to authorities Overload due to binding Contact Supplier in pump or wrong size impeller WARNING If the pump is within the stated warranty period and you experience faults always contact your supplier Failure to do this may void warrant...

Reviews: