MSR112 Programmer’s Manual UDN PM019 Rev. A
Section 5 -- Configuration Commands 2002/5/23
Page
18
Uniform Industrial Corp.
Proprietary and Confidential
Total 18 pages
EDx (45h 44h x)
-
-
-
-
Set output data format while read error.
x = E or F (4Eh or 4F enable) or D (44h disable, no data is output). Default setting is E.
Please refer to “transmission format” in section 3 for details.
STx (53h 54h x)
-
-
-
-
STX Enable/Disable
x = E (45h enable) or D (44h disable)
Please refer to “transmission format” in section 3 for details.
ETx (53h 54h x)
-
-
-
-
ETX Enable/Disable
x = E (45h enable) or D (44h disable)
Please refer to “transmission format” in section 3 for details.