background image

 

TBOX COMPETITION 

 
Short operating instruction   

 

 

03.09.20 Rev.A5 m. (subject to change) 

 

Key facts 
 

Description: TBox Competition 

 

 

Ref.: 13620

 

Price: 231,09 Euro/net 
Measurement: 11 x 7 x 3,5 cm 
Weight: 0,186 kg 

                                                                                                         

 

Introduction

 

 

The TBOX Competition is a precision measuring device that can test weapons, cables and 
conductive materials (vest, mask bib). Six test modes are currently available (3 for weapons, 
2 for cables and 1 for conductive materials). The handy test device is powered by a 9 V block 
battery and operated with just one button. Alternatively, it can be supplied with voltage via 
the integrated micro-USB port and remotely controlled by using an app. Thanks to the 
visualization of the results in the app and standardized test routines, the device can also be 
used for FIE weapon control optimally. A total of 6 bright RBG LED are available to signal the 
test mode and the measuring results. Measuring results are partly given by an acoustic 
signal. The device has a Kensington lock device and it can be stored theft protected. Software 
updates or functional expansions can easily be uploaded via the micro-USB in connection 
with a laptop / PC. 

 

Appliance 

 

The test device is operated with just one button. 
Pressing and holding the white button switches the device on and off or changes the test 
mode. 
Briefly pressing the key resets the measuring results of the current test mode and the 
measuring starts again. 
 
The device has a total of six RGB LED. Each individual LED can light up in different colors. 
Three LED are arranged directly above the button and signal the current test mode (mode 
LED). If one of the three mode LED is red, a weapon test mode is selected. If one of the mode 
LED is green, a cable test mode or conductive substance test is selected. If a LED is blue, the 
test mode is for permanently installed or long lines. 

Summary of Contents for TBOX COMPETITION

Page 1: ...ht RBG LED are available to signal the test mode and the measuring results Measuring results are partly given by an acoustic signal The device has a Kensington lock device and it can be stored theft p...

Page 2: ...shing mode LED and can no longer be used In battery mode the device is automatically switched off after 30 seconds of inactivity To switch off the device manually hold the button down until all three...

Page 3: ...eck mode 3 Sabre Connect a saber to a body cord on the right side of the tester The crocodile clip for connecting the vest can be attached to the conductive fabric part at the top of the device Press...

Page 4: ...he LED light up green for a resistance 3 0 Ohm yellow for a resistance between 3 1 ohms and 5 0 ohms red for a resistance 5 0 Ohm Micro interruptions are also indicated by a red LED The worst signaled...

Page 5: ...r on the test accessory Press the button on the device and hold it down until the left mode LED lights up blue Release the button now The three measuring LED indicate the resistance of the three wires...

Page 6: ...t ref 13620 2 to a mains supply at a voltage of 100 240 V 50 Hz The devices should only be connected to the electricity supply system after all cables have been installed For absolutely safe disconnec...

Page 7: ...anpower Defective power cord or socket The device has been exposed to moisture or rain Water has penetrated or an object has fallen into the device The device shows serious functional changes and is n...