background image

 
 

 

 

CX2122/24/26

 

Clex private

 

Electronic knob module 

Operating and 

assembly manual 

 

Summary of Contents for Clex private CX2120

Page 1: ...CX2122 24 26 Clex private Electronic knob module Operating and assembly manual...

Page 2: ...tenbergstra e 2 4 97297 Waldb ttelbrunn Germany Phone 49 931 40672 0 E Mail contact UundZ de http www UundZ de This operating and assembly manual is copyright protected The information contained this...

Page 3: ...10 4 Assembly 11 4 1 Assembly instructions 11 4 2 Assembly 12 5 Commissioning 14 5 1 Memorize service key 14 5 2 Management as learning clearing system 14 5 3 Management with Keyng CX2530 15 5 4 Chang...

Page 4: ...or disruptions or hazards such as non access to injured personnel malfunctions property damage or other damages resulting from non compliance with this operating and assembly manual or incorrectly con...

Page 5: ...edication fire extinguishers etc 2 3 General safety instructions Follow these basic safety instructions when using the knob cylinder Installation and battery replacement should only be done by qualifi...

Page 6: ...the battery power reduces capacity loss during the final 1 000 operations of the battery see chapter7 2 1 Battery Replacement Signaling happens in 3 phases The battery needs to be changed soon If an a...

Page 7: ...le to comply with specific data privacy guidelines The event log can be read via the CX2530 Keyng 3 1 3 Locking time The locking time defines how long the knob module remains connected after scanning...

Page 8: ...2 CX2124 1 Knob sleeve 4 Fixing screw 2 Battery 5 Cylinder casing 3 Electronic knob 6 Sleeve locking pin 3 2 3 CX2126 1 Fixing screw 4 Sleeve locking pin 2 Cylinder casing 5 Electronic knob 3 Battery...

Page 9: ...es available upon request Cylinder lengths CX2126 From 26 10 mm or 30 10 mm to 200 10 mm in 5 mm steps over sizes available upon request Length of the knob 42 7 mm indoor version 44 8 mm outdoor versi...

Page 10: ...CX2122 24 26 PRODUCT DESCRIPTION 9 3 4 3 Dimensions 40 0 42 7 23 5 14 0 44 8 23 5 O45 0 O14 0 40 0 42 7 A B 29 0 20 0 40 0 40 0 42 7 42 7 A B 40 0 42 7 A 10 CX2120 CX2120 IP66 CX2122 CX2124 CX2126...

Page 11: ...ptional addition to the Keyng software and helps conveniently read the key 3 5 4 Service key Using the service key a user identifies himself as an administrator of the locking system If the service ke...

Page 12: ...ng To activate the knob module insert the batteries or remove the battery tag if present and close the casing see chapter 7 2 1 Changing batteries Before mounting the knob module always check that all...

Page 13: ...t cylinder Push in CX212x cylinder casing and fasten with fixing screw Tighten the fixing screw by hand do not use a battery operated screwdriver with a high torque The cylinder body must not project...

Page 14: ...2122 24 26 ASSEMBLY 13 The electronic knob is mounted into the cylinder casing by inserting and turning at the same time Make sure that the knob cylinder operates easily and smoothly with the door ope...

Page 15: ...rizing the service key the battery change and the disassembly card also need to be memorized To do this first hold the service key in front of the knob module followed by the battery change card and f...

Page 16: ...short audible signals After the programming mode has been exited after 15 seconds all keys have been deleted 5 3 Management with Keyng CX2530 The CX2530 Keyng software enables convenient and easy man...

Page 17: ...thout reading a key then automatic wake up is disabled In this case the knob module has to be woken up manually Turn the knob module few times to wake up the reading unit until an LED starts glowing H...

Page 18: ...locking direction until it stops The door can now be opened with the door handle 6 3 Toggling the knob module Hold the key with toggle authorization for two cycles in front of the reading unit Dependi...

Page 19: ...LEDs start glowing Key authorized Green LEDs start glowing Time changeover toggling On Long high audible signal green LEDs start glowing Time changeover toggling Off Long high audible signal red LEDs...

Page 20: ...atteries with new batteries Pay attention to the correct polarity when inserting the batteries Change the battery only with the door open As long as the battery is removed the knob module cannot engag...

Page 21: ...ng the step 1 or by presenting an authorized key the knob module returns to the home position When managing the locking system using the Keyng software check the knob module time using Keyng CX2530 an...

Page 22: ...s are visible The smaller one is on the side away from the door To remove the sealing rings hold the respective sealing ring on one side with the thumb while pushing on the opposite side with the fing...

Page 23: ...als RTC fault clock 5 long audible signals 3 brief audible signals Internal fault unhandled interrupt 5 long audible signals 4 brief audible signals Internal fault Bus conflict 5 long audible signals...

Page 24: ...le into the disassembly position by presenting the disassembly card or using Keyng CX2530 Turn the knob module by lightly pulling it until it can be removed from the cylinder Disassembly is only possi...

Page 25: ...should be in accordance with the European Directive 2002 96 EC at a collection point for electrical waste Defective or used batteries should be recycled in accordance with the European Directive 2006...

Page 26: ...ta carrier that contains the authorization information This can for example be an ISO card or a chip The key is sometimes also known as transponder Service key A special key with which you can identif...