CV

 

Description

 

 

Value range

 

Value ex 
works

 

165

 

Servo control, servo 2 rotation time in 100ms steps

 

 

0-255

 

30

 

166

 

Servo control via SUSI, 1 = on, 0 = off

 

 

0, 1

 

0

 

167

 

Function key number for Servo 1 SUSI-Data

 

 

0-28

 

7

 

168

 

Function key number for Servo 2 SUSI-CLK

 

 

0-28

 

8

 

170

 

Assignment PWM curve for light output

 

 

0-8

 

0

 

 

History 1 - 8, bit 7 = 1 -> History only active if CROSS output bit is set

 

 

129-136

 

 

171

 

Assignment PWM curve for function output A1

 

 

0-8

 

0

 

 

History 1 - 8, bit 7 = 1 -> History only active if CROSS output bit is set

 

 

129-136

 

 

172

 

Assignment PWM curve for function output A2

 

 

0-8

 

0

 

 

History 1 - 8, bit 7 = 1 -> History only active if CROSS output bit is set

 

 

129-136

 

 

178

 

PWM history,

 period of playback (value * 64ms)

 

 

0-255

 

15

 

179

 

PWM curve,

 phase position of the outputs

 

 

Wert

 

0-7

 

0

 

 

Bit 0 = 0

 

A0h -> Phase position 0°

 

 

0*

 

 

 

 

Bit 0 = 1

 

A0h -> phase position 180°

 

 

1

 

 

 

 

Bit 1 = 0

 

A1 -> phase position 0°

 

 

0*

 

 

 

 

Bit 1 = 1

 

A1 -> phase position 180°

 

 

2

 

 

 

 

Bit 2 = 0

 

A2 -> phase position 0°

 

 

0*

 

 

 

 

Bit 2 = 1

 

A2 -> phase position 180°

 

 

4

 

 

 

180

 

PWM

 curve, hold time, after the CROSS output bit off (value * 100ms)

 

 

0-255

 

0

 

181

 

Firebox varnishes of light and function outputs A1 & A2

 

 

0-7

 

0

 

 

bit 0-2 -> A0 to A2; bit = 0 flickering, bit = 1 flickering

 

 

 

 

182

 

Firebox Polishers, Flicker Settings

 

 

0-255

 

0

 

 

Bit 0-3 -> Change flicker rhythm (value range 1 to 15)

 

 

 

 

 

Bit 4-6 -> Change brightness (value range 16, 32, 48, 64, 80, 96, 112)

 

 

 

 

 

bit 7 = 1 -> output always bright (combinable with bit 4-6)

 

 

 

 

183

 

Energy saving lamp effect of light and function outputs A1 & A2

 

 

0-7

 

0

 

 

bit 0-2 -> A0 to A2; Bit = 0 effect off, bit = 1 effect on

 

 

 

 

184

 

Energy

 saving lamp effect, basic brightness

 

 

0-63

 

10

 

185

 

Energy

 saving lamp effect, time until maximum brightness is reached (value * 

5ms)

 

0-255

 

100

 

186

 

Fade-in and fade-out of light and function outputs A1 & A2

 

 

0-7

 

0

 

 

bit 0-2 -> A0 to A2; Bit = 0 blend function off, bit = 1 blend function on

 

 

 

 

187

 

Fade in and fade out, fade

 time (value * 1ms)

 

 

0-255

 

30

 

188

 

Neon tubes Switching on effect of light and function outputs A1 & A2

 

 

0-7

 

0

 

 

bit 0-2 -> A0 to A2; Bit = 0 effect off, bit = 1 effect on

 

 

 

 

189

 

Neon tubes turn on

 effect, flash time (value * 5ms)

 

 

0-255

 

20

 

190

 

Neon tubes turn on

 effect, maximum flash count

 

 

0-255

 

20

 

200

 

Motor control, speed-dependent period

 

 

0-255

 

10

 

 

minimum speed up to which the period duration = CV53 is set

 

 

 

 

201

 

maximum speed from which the period = CV202 is set

 

 

0-255

 

150

 

202

 

maximum period duration in 100µs steps (min=CV53)

 

 

0-255

 

250

 

 

* Factory set values

 

 

CV table for programming the banks 1 - 4

 

 

CV

 

Bank 1, extended mapping, lines 1 - 16 (CV31=8,CV32=0), values ex works

 

Value range

 

257-272

 

Condition ON: 144, 0, 0, 0, 0, 0, 0, condition OFF: 0, 0, 0, 0, 0, 0, output: 0, 1, 0, 0,

 

0 - 255 each

 

273-288

 

Condition ON: 16, 0, 0, 0, 0, 0, 0, condition OFF: 128, 0, 0, 0, 0, 0, output: 0, 2, 0, 0,

 

0 - 255 each

 

289-304

 

Condition ON: 1, 0, 0, 0, 0, 0, 0, Condition OFF: 0, 0, 0, 0, 0, 0, output: 1, 0, 0, 0,

 

0 - 255 each

 

305-320

 

Condition ON: 2, 0, 0, 0, 0, 0, 0, Condition OFF: 0, 0, 0, 0, 0, 0, output: 2, 0, 0, 0,

 

0 - 255 each

 

321-336

 

Condition ON: 0, 0, 0, 0, 0, 0, 0, condition OFF: 0, 0, 0, 0, 0, 0, output: 0, 0, 0, 0,

 

0 - 255 each

 

337-352

 

Condition ON: 0, 0, 0, 0, 0, 0, 0, condition OFF: 0, 0, 0, 0, 0, 0, output: 0, 0, 0, 0,

 

0 - 255 each

 

353-368

 

Condition ON: 0, 0, 0, 0, 0, 0, 0, condition OFF: 0, 0, 0, 0, 0, 0, output: 0, 0, 0, 0,

 

0 - 255 each

 

369-384

 

Condition ON: 0, 0, 0, 0, 0, 0, 0, condition OFF: 0, 0, 0, 0, 0, 0, output: 0, 0, 0, 0,

 

0 - 255 each

 

385-400

 

Condition ON: 0, 0, 0, 0, 0, 0, 0, condition OFF: 0, 0, 0, 0, 0, 0, output: 0, 0, 0, 0,

 

0 - 255 each

 

401-416

 

Condition ON: 0, 0, 0, 0, 0, 0, 0, condition OFF: 0, 0, 0, 0, 0, 0, output: 0, 0, 0, 0,

 

0 - 255 each

 

417-432

 

Condition ON: 0, 0, 0, 0, 0, 0, 0, condition OFF: 0, 0, 0, 0, 0, 0, output: 0, 0, 0, 0,

 

0 - 255 each

 

433-448

 

Condition ON: 0, 0, 0, 0, 0, 0, 0, condition OFF: 0, 0, 0, 0, 0, 0, output: 0, 0, 0, 0,

 

0 - 255 each

 

449-464

 

Condition ON: 0, 0, 0, 0, 0, 0, 0, condition OFF: 0, 0, 0, 0, 0, 0, output: 0, 0, 0, 0,

 

0 - 255 each

 

465-480

 

Condition ON: 0, 0, 0, 0, 0, 0, 0, condition OFF: 0, 0, 0, 0, 0, 0, output: 0, 0, 0, 0,

 

0 - 255 each

 

481-496

 

Condition ON: 0, 0, 0, 0, 0, 0, 0, condition OFF: 0, 0, 0, 0, 0, 0, output: 0, 0, 0, 0,

 

0 - 255 each

 

497-512

 

Condition ON: 0, 0, 0, 0, 0, 0, 0, condition OFF: 0, 0, 0, 0, 0, 0, output: 0, 0, 0, 0,

 

0 - 255 each

 

Summary of Contents for Intelli Drive 2

Page 1: ...g track 8 Power consumption right red when the programming mode of the control panel is called up When reading or programming very small currents usually flow which do not damage the decoder in the ev...

Page 2: ...de de_DE service download konformit tserkl rung index htm Our advantages for you If you have any questions we are here for you Internet FAQs can be found at www uhlenbrock de E Mail service uhlenbrock...

Page 3: ...tion outputs A1 A2 in the user manual do not apply to the decoder 73115 with 6 pin NEM 651 interface Analog operation with DC voltage The locomotive decoder is suitable for analog operation with DC vo...

Page 4: ...teps via CV 2 CV 5 and CV 6 0 Use characteristic curve from CV 67 94 16 5 Kurze Adresse CV 1 Register 1 0 Long address CV 17 and 18 32 Bit Konfiguration CV 50 Wert 0 Do not use Motorola 2nd address 0...

Page 5: ...1st edition of this description remains valid If braking is initiated with a constant braking distance the decoder only responds to driving commands again when the locomotive has come to a standstill...

Page 6: ...If such an output is switched on via a wireless button it is automatically switched off in the desired direction of travel CV113 2 A1 forward from CV113 4 A2 forward from CV113 8 A3 forward from CV113...

Page 7: ...switch off automatically after an adjustable time without having to switch off the function key Furthermore the decoder can ensure that the coupling is only actuated for a short switch on moment with...

Page 8: ...veral outputs starting and braking delays shunting second dimming of the function outputs SUSI as logic level output transfer of the function keys F22 to F28 to SUSI as well as the setting of the CROS...

Page 9: ...la 256 line 1 16 bytes Formula 256 line 17 16 bytes The bit structure and the values to be programmed accordingly in the CVs are comparable to the configuration CVs of the decoder This means that ther...

Page 10: ...CV 272 1 To facilitate programming especially for extended function mapping the programming software Lok Tool can be used which is included with the digital programming and test station DigiTest from...

Page 11: ...From decoder software version 23 CV7 3rd edition 25 02 19...

Page 12: ...ecoders Programming with a M rklin control unit eg 6021 With a M rklin control panel all CVs can be programmed but not read out The decoder can be put into programming mode in two ways a and b dependi...

Page 13: ...255 255 Bit 0 0 DC analog operation direct current off 0 Bit 0 1 DC analog operation direct current on 1 Bit 2 0 Data format DCC from 0 Bit 2 1 Data format DCC a 4 Bit 3 0 Data format Motorola from 0...

Page 14: ...ht A1 and A2 156Hz 0 Bit 3 1 Frequency light A1 and A2 24KHz 8 Bit 4 0 SUSI SUSI 0 Bit 4 1 SUSI A3 A4 output function mapping table 16 51 Decoder Konfiguration 2 Wert 0 135 3 131 Bit 0 0 Motor control...

Page 15: ...value 200ms 16 240 131 Dynamic smoke generator control load threshold 0 255 5 132 Dynamic smoke generator control PWM normal operation 0 63 16 133 Dynamic smoke generator control PWM idle stand 0 63...

Page 16: ...164 Servo control Servo 2 position 2 function key on 0 255 200...

Page 17: ...es Switching on effect of light and function outputs A1 A2 0 7 0 bit 0 2 A0 to A2 Bit 0 effect off bit 1 effect on 189 Neon tubes turn on effect flash time value 5ms 0 255 20 190 Neon tubes turn on ef...

Page 18: ...16 24 32 48 63 63 63 63 48 32 24 16 8 3 0 63 each until 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 63 each 320 3 8 16 24 32 48 63 63 63 63 48 32 24 16 8 3 0 63 each 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 63 each 3...