CAUTION!
If connections at the dosing head are loosened during operation, for venting or other reasons, leaking chemical must be removed properly. This is the only way to
avoid health hazards due to chemicals, and chemical corrosion of the dosing pump. Leaking chemical may also damage the diaphragm at its mounting edge.
ATTENTION!
If changing the chemical, check the materials in the pump and other system parts for chemical resistance. If there is a danger of chemical reaction between the
different media, clean thoroughly beforehand.
IMPORTANT!
To operate the pump, mount the fan cowl in order to ensure sufficient cooling of the motor.
The protection class of the control unit is only ensured if the connection ports are protected by caps or the standard connectors are inserted.
DANGER!
Fire hazard. Shock wave: parts may fly off and cause fatal injury. Encore
®
MB must never be used in areas with a potentially explosive atmosphere.
CAUTION!
Under certain operating conditions, the drive motor of the Encore
®
MB version might heat up considerably. This may cause burns to the hands. To avoid uninten-
tional contact, provide an appropriate safety device.
WARNING!
Lethal voltage!
Adjustment work inside the ATE servomotor (optional for Encore
®
ME) must be carried out carefully. Connections and internal limit switches might be live.
Additional limit switches might be live even when the auxiliary voltage is switched off (ATE servomotor). After installation work on the ATE servomotor, or before
start-up, re-attach the cover.
1.12 Transportation
No special devices are required for transportation of the dosing pumps. However, it is advisable to choose a transport method appropriate for the weight of the
dosing pumps (e.g. transport trolley). If transporting with the oil drained, the dosing pump should preferably be placed in the horizontal position. Otherwise, stabil-
ity must be ensured by screwing it onto the transport frame.
1.13 Scope of delivery
IMPORTANT!
Carefully unpack the dosing pump and any accompanying accessories ordered, so that small parts are not left inside the packaging. Compare the delivery
content with the delivery note immediately. If there are any discrepancies, find out the cause.
The following are part of the scope of delivery:
•
Encore
®
dosing pump
•
Suction and discharge side connections
•
Gear oil
•
2x cables (for Encore
®
MB)
•
Operation manual
•
ATE servomotor (optional)
•
Separate fan (optional)
8
Diaphragm Dosing Pump
Encore
®
MB/ME
Operating Instructions
CF.450.410.001.IM.1114
Summary of Contents for Encore MB
Page 3: ...3 Diaphragm Dosing Pump Encore MB ME Operating Instructions CF 450 410 001 IM 1114 ...
Page 48: ...48 Diaphragm Dosing Pump Encore MB ME Operating Instructions CF 450 410 001 IM 1114 ...
Page 50: ...19 Notes 50 Diaphragm Dosing Pump Encore MB ME Operating Instructions CF 450 410 001 IM 1114 ...
Page 51: ...51 Diaphragm Dosing Pump Encore MB ME Operating Instructions CF 450 410 001 IM 1114 ...
Page 52: ...Encore MB ME Diaphragm Dosing Pump MANUAL NO CF 450 410 001 IM 1114 CF 450 420 001 IM 1114 ...