Key
Display Description
Key
Display Description
Mode +
▼
INT
Manual control
Mode +
▼
64.1
Pulse control
▼
1.64
Pulse control
▼
32.1
▼
1.32
▼
16.1
▼
1.16
▼
8.1
▼
1.8
▼
4.1
▼
1.4
▼
2.1
▼
1.2
▼
1.1
▼
4.20
Analogue control
▼
0.20
Manual control
The dosing pump delivers a constant flow of chemical per unit time, regardless of the process.
To set this operating mode, proceed as follows:
1. Press the "Mode" and
▲
or
▼
keys simultaneously until INT is displayed.
2. Release the "Mode" key. The current stroke frequency is displayed (strokes/min)
3. Use the
▲
and
▼
keys to change the stroke frequency.
Pulse control
The dosing pump delivers a constant flow of chemical per input pulse. Up to 64 pulses are buffer-stored if the pulse rate exceeds the processing speed. To set the pulse multiplica-
tion/division, simultaneously press the "Mode" and
▲
or
▼
keys until one of the following values is displayed:
•
for a ratio of 1:1, i.e. the dosing pump executes one dosing stroke after each pulse,
•
1.2 to 1. 64 for pulse multiplication or
•
2.1 to 64. 1 for pulse division
The "Extern" indicator is lit.
Settings for pulse multiplication and division: 1, 2, 4, 8, 16, 32 and 64.
Example
1. 64
The dosing pump executes 64 dosing strokes after each pulse.
64. 1
The dosing pump executes one dosing stroke after 64 pulses.
Analogue control
The dosing pump doses proportionally to the input signal. To set the operating mode, press the "Mode" and
▲
or
▼
keys simultaneously until one of the following values is dis-
played:
•
0. 20 for 0...20 mA signal or
•
4. 20 for 4...20 mA signal
When the "Mode" key is released, the stroke frequency corresponding to the current is displayed. The "Extern" indicator is lit. If the current is greater than 20 mA (display: OVL) or
less than 4 mA (display: E-I), the alarm indicator is lit, the warning alarm relay switches and the dosing pump stops. The stroke frequency of the dosing pump is proportional to the
input signal.
8.5 Alarm
The dosing pump allows monitoring of the dosing process. An alarm is indicated visually on the display and transmitted by the warning alarm relay.
Alarm LED
Alarm relay
Pump
Display
Level pre-alarm
flashes
switches
continues to operate
Number of strokes
Level main alarm
is lit
switches
stops
E - L
27
Diaphragm Dosing Pump
Encore
®
MB/ME
Operating Instructions
CF.450.410.001.IM.1114
Summary of Contents for Encore MB
Page 3: ...3 Diaphragm Dosing Pump Encore MB ME Operating Instructions CF 450 410 001 IM 1114 ...
Page 48: ...48 Diaphragm Dosing Pump Encore MB ME Operating Instructions CF 450 410 001 IM 1114 ...
Page 50: ...19 Notes 50 Diaphragm Dosing Pump Encore MB ME Operating Instructions CF 450 410 001 IM 1114 ...
Page 51: ...51 Diaphragm Dosing Pump Encore MB ME Operating Instructions CF 450 410 001 IM 1114 ...
Page 52: ...Encore MB ME Diaphragm Dosing Pump MANUAL NO CF 450 410 001 IM 1114 CF 450 420 001 IM 1114 ...