UFO UFO-L/12 User Manual Download Page 8

3.1 Installation Instructions

Installation on the wall: Attention! The appliance must be installed on the solid surfaces like concrete
and metal.

Never install on flammable surfaces!

See pages 4-7 to come up with the most appropriate installation method for your UFO.

UFO User Manual & Certificate Of Warranty

4

3. INSTALLATION

1- Drill four  8 mm diameter holes on the wall to the place where the unit will be placed with the
distances shown in (Figure-1)

2- Insert the 8 mm diameter wall plugs,supplied with the unit ,into the holes.

3- Mount two of the L shaped legs on the wall using the 5x40 screws supplied with the unit.

4- Mount the other L legs on the unit using the six M5 screws and the small wrench as shown in

(Figure-2) (corresponding nuts are already built in on the body of the unit)

5- Mount and fix the L shape legs on the wall and on the unit respectively,using the M8x13 bolts and
nuts and the washers as shown in (Figure-3) and tighten by using the wrench supplied.

6- Depending on the area to be heated the angle of the unit can be adjusted between 0-45 degrees
by the help of M8 bakelite head bolt and nut fixture.

7- Before operating the unit joints should be checked once again.

Figure-4

Figure-3

Figure-2

Figure-1

Summary of Contents for UFO-L/12

Page 1: ......

Page 2: ......

Page 3: ......

Page 4: ...tion and maintenance are of great importance for the security of you and of those who are to benefit from the heater The difference between UFO Classic UFO Line and UFO Star models is the duration of...

Page 5: ...5 Technical Information Heating Area Size 8 6 Operating Instructions 9 6 1 UFO Line UFO Star 9 6 2 UFO Line UK 10 6 2 1 Definitions of the Buttons on the Remote Control 10 6 2 2 Definitions and Functi...

Page 6: ...bc in horizontal position or of vertical operations the heating loop wire may fall into disuse shortly Never install your appliance on a combustible surface carton etc The distance of your appliance f...

Page 7: ...min 0 6 m The distance of 1 m is recommended for more safety The distance of the earthed plug from bath tub washbasin or other sanitary installations must be min 0 6 m 1 m distance is recommended for...

Page 8: ...into the holes 3 Mount two of the L shaped legs on the wall using the 5x40 screws supplied with the unit 4 Mount the other L legs on the unit using the six M5 screws and the small wrench as shown in...

Page 9: ...ions Attention Fixing only at 5 horizontally is of great importance for permanent operation WRONG RIGHT Safety Distances Minimum distances required for safety Minimum distances from wall corners Minim...

Page 10: ...ns 6 WRONG WRONG RIGHT RIGHT WRONG RIGHT DIRECT YOUR HEATER TOWARDS THE MOST APPROPRIATE ANGLE Do not let the light out through window glasses etc as the heater primarily heats the locations onto whic...

Page 11: ...om Corridor Bathroom Nursery room for babies Study room Summer house Hobby house Swimming pool Office Meeting room Entrance Workshop Shop Internet cafe Shopping centre Showrooms Swimming pool Classroo...

Page 12: ...15 12 18 23 30 UFO LINE Hertz Hz 50 60 50 60 50 60 50 60 50 60 50 60 UFO S 12 UFO S 15 UFO S 18 UFO S 23 UFO S 30 110 120 110 120 220 230 220 230 220 230 1200 1400 1500 1700 1800 2000 2300 2500 2900 3...

Page 13: ...r may be operated with certain intervals adjusting the thermostat 21 24 C You may reduce the energy costs to the minimum level in certain room temperatures through appropriate thermostat adjustment Sw...

Page 14: ...eries of your remote control 9 1 2 5 8 7 6 4 3 1 On Off Switches on or off the heater or stands it by 2 Program Up Down Adjusts program settings 3 Clock Sets the time 4 Timer On Switches on the heater...

Page 15: ...e Remote Control UFO User Manual Certificate Of Warranty 11 Symbol Power mode indicator Time settings indicator On time indicator Off time indicator Indicates remaining time to switch off the heater I...

Page 16: ...een Power mode indicator mode1 starts functioning after pressing On Off button 1 Flip the backside of your remote control and pull out battery cover Insert the batteries in accordance with the instruc...

Page 17: ...ess buttons to set hour and minutes Press Clock button to save your settings Press Cancel button to cancel time settings NOT Repeated presses on the buttons will gear the speed of buttons and interval...

Page 18: ...l button to cancel all time settings The settings will recede unless you press Clock Timer On Sleep ve Timer Off necessary button to save your time settings in 20 seconds Press Cancel button to cancel...

Page 19: ...t indicator starts functioning and 2 3 indicator appears on the screen warning through a buzzer voice when the heater operates in a slope larger than 5 The heater starts operating in stand by mode H0...

Page 20: ...ody material Warranty Filament life time Hours Plastic Cover Power cord length Remote control Reflector Reflector side part Grid Wire Voltage Frequency Naturel Champagne Aluminium 2 years 3 years 4 ye...

Page 21: ...ally while cleaning the appliance In case of any deformation consult to your technical service 5 It is recommended to change the Reflector every 2 years for the purposes of more efficient operation of...

Page 22: ...n 0 mode 2 Make sure that the plug to which the appliance is connected has power check the fuse and power cord If the plug lacks power consult to an electrician 3 Make sure that the appliance has been...

Page 23: ...ir Attention Faulty maintenance and cleaning are not covered by the warranty 1 The dust and polluters in the environment 2 Damage in the reflector or filament due to faulty cleaning 3 Faulty installat...

Page 24: ...Notes 20 ENGLISH UFO User Manual Certificate Of Warranty...

Page 25: ......

Page 26: ...ppropri s sont de grande importance pour s curit de vous et de ceux qui l utiliserons La diff rence des mod les entre le classique d UFO la ligne d UFO et d UFO toile est la long vit des filaments uti...

Page 27: ...information technique surface de chauffe taille 8 6 Consignes d utilisation 9 6 1 UFO Line UFO Star 9 6 2 UFO Line UK 10 6 2 1 D finitions des boutons sur la t l commande 10 6 2 2 D finitions et fonct...

Page 28: ...reil d UFO D branchez votre appareil quand vous ne l utilisez pas pour un long terme ou en cas de nettoyage et d entretien B Distances de s curit requises pour l installation sur le mur la temp rature...

Page 29: ...mmand e pour plus de s ret La distance de la prise mise la terre du baquet de bain du lavabo ou d autres installations sanitaires doit tre 0 6 M minimum La distance de 1 m est recommand e pour plus de...

Page 30: ...au dessus d o le r chauffage doit tre install 2 Placez 8 prise de mur que vous trouverez dans la bo te de votre r chauffeur dans les trous 3 Fixez 2 crochets de mur sur le mur avec le tournevis utili...

Page 31: ...appareil doit tre install sur les surfaces pleines comme le b ton et le m tal N installez jamais sur les surfaces inflammables Voir les pages 4 7 pour proposer la m thode d installation la plus approp...

Page 32: ...RE r chauffeur R CHAUFFAGE VERS L ANGLE LE PLUS APPROPRI Ne laissez pas la lumi re dehors par la fen tre les verres etc comme le r chauffeur chauffe principalement les endroits sur lesquels sa lumi re...

Page 33: ...cher Salle de bains Pi ce de Nursery pour des b b s Pi ce d tude Maison secondaire Piscine Bureau Salle de r union Entr e Atelier Magasin Serre Caf d Internet Centre commercial Salles d exposition Pis...

Page 34: ...rieur m2 12 15 12 18 23 30 UFO LINE 50 60 50 60 50 60 50 60 50 60 50 60 UFO S 12 UFO S 15 UFO S 18 UFO S 23 UFO S 30 110 120 110 120 220 230 220 230 220 230 1200 1400 1500 1700 1800 2000 2300 2500 290...

Page 35: ...ir e a t atteinte le r chauffeur peut tre actionn avec certains intervalles ajustant le thermostat 21 24 C Vous pouvez ramener les co ts nerg tiques au niveau minimum dans certaines temp ratures ambia...

Page 36: ...ou le tient pr s 2 programme haut bas Ajuste des arrangements de programme 3 Horloge Place le temps 4 Temporisateur dessus Commutateurs sur le r chauffage en mode stand by 5 Temporisateur au loin Com...

Page 37: ...rtificat de la garantie 11 Symbole Description Indicateur de mode de puissance Indicateur de r glages de temps Indicateur du temps a la mode ouvert Indicateur du temps a la mode ferme Indicateur du te...

Page 38: ...mani re repr sent es ci dessus Notice 1 Remplacez les batteries anciennes avec le m me type batteries Autrement votre t l commande peut ne pas fonctionner bien 2 Retirez les batteries en cas de longue...

Page 39: ...minutes Appuyez sur le bouton de Clock pour sauver vos arrangements Appuyez sur le bouton de Cancel pour d commander des arrangements de temps PS Les presses r p t es sur les boutons embrayeront la vi...

Page 40: ...ngements de temps Les arrangements reculeront moins que vous appuyiez sur l horloge Clock temporisateur du VE dessus Timer On sommeil Sleep sommeil au loin Timer Off le bouton n cessaire pour sauver v...

Page 41: ...es d buts d indicateur fonctionnant et l indicateur 2 3 appara t sur l avertissement d cran par une voix de vibreur quand le r chauffeur fonctionne dans une pente plus grande que 5 Le r chauffeur d ma...

Page 42: ...de mat riel Garantie le temps de Filament Heures Couverture en plastique Longueur de cordon de secteur T l commande R flecteur Pi ce lat rale de r flecteur Fil de grille Voltage Fr quence Naturel Cha...

Page 43: ...uelle d formation consultez votre service technique 5 On lui recommande de changer le r flecteur tous les 2 ans aux fins d une op ration plus efficace de votre appareil Nettoyage Attention Le nettoyag...

Page 44: ...t en 0 modes 2 2 Assurez vous que la prise laquelle l appareil est reli a la puissance v rifiez le fusible et le cordon de secteur Si la prise manque de la puissance consultez un lectricien 3 3 Assure...

Page 45: ...d fectueux ne sont pas couverts par la garantie 1 La poussi re et les pollueurs dans l environnement 2 Endommagez dans le r flecteur ou le filament d au nettoyage d fectueux 3 Installation ou d mant...

Page 46: ...Notes 20 Manuel d utilisation d UFO Certificat de la garantie FRAN AiS...

Page 47: ......

Page 48: ...o ru al t rma ve bak m siz ve s t c dan faydalanacak di er ki ilerin g venli i i in ok nemlidir UFO Line ve UFO Star r nlerimizin aras ndaki fark kullan lan filamentlerin m rleridir L tfen bu Kullan m...

Page 49: ...tma Alan l 8 6 al t rma Talimatlar 9 6 1 UFO Line UFO Star 9 6 2 UFO Line Uzaktan Kumanda 10 6 2 1 Uzaktan Kumandadaki Fonksiyon Tu lar n n Tan t m 10 6 2 2 Uzaktan Kumandadaki G stergelerin simleri v...

Page 50: ...mek i in cihaz n g kablosunu g r lebilir ve kolay eri ilebilir bir prize tak n z B Duvara Montaj Y ksek Is ve Yang n Korumas in G venli Mesafeler Dikkat Cihaz yaln zca yatay pozisyonda kullan lmal d r...

Page 51: ...nlerine dokunamayaca ekilde cihaz monte edilmelidir Cihaz n kullan laca toprakl priz ile k vet du lavabo ya da di er s hhi tesisatlarla aras nda minimum 1m mesafe olmal d r D Temizlik ve Bak m Talimat...

Page 52: ...ilece i yere d rt adet 8mm ap nda yukar daki izimde belirtilen l lerde delikler a n z ekil 1 2 Cihaz n kutusundan kan d rt adet 8 d beli deliklere yerle tiriniz 3 Cihaz kutusundan kan iki adet duvar t...

Page 53: ...isyonlar Dikkat Yaln zca yatay 5 de sabitleme uzun m rl olmas n sa lar YANLI DO RU G venli Mesafeler G venlik i in ihtiya duyulan minimum mesafeler Duvar k eleri ile minimum mesafeler Is tma alan ve n...

Page 54: ...zisyonlar C HAZ DO RU A IYLA Y NLEND R LMEL D R 6 YANLI YANLI DO RU DO RU YANLI DO RU Cihaz ncelikle n n d t yeri s tt ndan cam pencere gibi yerlerden n n d ar ya kmas na engel olunmal d r Ufo Kullan...

Page 55: ...ak m odas al ma odas Yazl k ya da apartman Hobi odas Y zme Havuzu Ofis Toplant odas Giri At lye Ma aza Sera nternet kafe Al veri merkezi Showroom i ve d ortam Y zme havuzu i ve d ortam S n f Konservat...

Page 56: ...LINE Hertz Hz 50 60 50 60 50 60 50 60 50 60 50 60 MODEL Is tma Alan V 10 Watt l Y cm D cm U cm UFO S 12 UFO S 15 UFO S 18 UFO S 23 UFO S 30 A rl k 110 120 110 120 220 230 220 230 220 230 1200 1400 15...

Page 57: ...s ya geldikten sonra termostat d mesi istenilen kademeye getirilerek cihaz n devreye girip kmas sa lan r Yap lan termostat ayar ile istenilen oda s cakl de erlerinde enerji tasarrufu sa lan r Bak m y...

Page 58: ...en kapatarak beklemeye al r 2 Program Yukar A a Program ayarlar n yapar 3 Clock Saat Saati ayarlar 4 Timer On A ma zamanlay c s Cihaz n beklemedeyken standby ayarlanan saatte a lmas n sa lar 5 Timer O...

Page 59: ...m K lavuzu Garanti Belgesi 11 G kademesi ayar g stergesi Saat ayar g stergesi Cihaz n a lma zaman n g sterir Cihaz n kapanma zaman n g sterir Cihaz n kapanmas i in kalan zaman saat olarak g sterir Ci...

Page 60: ...ama tu una bas l nca displayde g kademesi 1 kademe aktif hale gelir 1 Pilleri takmak i in uzaktan kumanda aletinin arkas n eviriniz ve pil b l m n n kapa n kar n z ve zerindeki talimatlara ve kutup se...

Page 61: ...aat tu una bas n Program esnas nda saat ayar fonksiyonunu iptal etmek i in Cancel ptal tu una bas n NOT Saat veya A ma Kapama zaman ayarlamas yap l rken tu lar na s rekli bas l nca kademeler h zl iler...

Page 62: ...as nda yap lan zaman ayarlar fonksiyonunu iptal etmek i in Cancel tu una bas lmal d r Program s ras nda yap lan saat ve dakika ayar n 20 sn i erisinde kaydetmek i in gerekli tu a Clock Timer On Sleep...

Page 63: ...n kullan l r Cihaz 5 zerinde e im ile al t zaman devrilme sens r aktif hale gelir ve display ekranda Er yaz s yazarak buzzer ile sesli sinyal verir Cihaz normal al ma konumuna getirildi inde cihaz sta...

Page 64: ...de Garanti S resi Filament mr Saat Plastik Kapak G Kablosu Kordon Boyu Uzaktan Kumanda Reflekt r Yans t c ayna Yan Reflekt r Koruma Kafes Teli al ma Gerilimi al ma Frekans Naturel ampanya Al minyum 2...

Page 65: ...iki y lda bir de i tirilmesi nerilir Reflekt r yetkili servis taraf ndan de i tirilmeli ve orjinal UFO reflekt r kullan lmal d r Reflekt r n temiz olmas cihaz n s tma veriminin max seviyede olmas n s...

Page 66: ...u prizde elektrik olup olmad sigorta ve g kablosunun sa laml kontrol edilmelidir E er prizde elektrik yoksa bir elektrik teknisyeni ile temasa ge ilmelidir 3 Yap lan montaj n bu kullanma k lavuzunda...

Page 67: ...LYA ANTALYA ANTALYA ANTALYA ANTALYA ANTALYA ARDAHAN ARTV N AYDIN AYDIN AYDIN AYDIN AYDIN BALIKES R BALIKES R BALIKES R CEYHAN SEYHAN SEYHAN SEYHAN SEYHAN SEYHAN MAMO LU KOZAN Y RE R SEYHAN SEYHAN G LB...

Page 68: ...ZL DEN ZL D YARBAKIR D YARBAKIR D YARBAKIR D YARBAKIR D YARBAKIR D YARBAKIR D ZCE ED RNE ED RNE ED RNE ED RNE ELAZI ERZ NCAN ERZ NCAN ERZURUM ERZURUM BANDIRMA BURHAN YE MERKEZ G NEN MERKEZ MERKEZ OSM...

Page 69: ...NBUL STANBUL STANBUL STANBUL STANBUL STANBUL STANBUL STANBUL STANBUL STANBUL STANBUL STANBUL STANBUL STANBUL STANBUL STANBUL STANBUL SP R OLTU MERKEZ SEY TGAZ ISLAH YE MERKEZ N Z P AH NBEY MERKEZ MERK...

Page 70: ...R ZM R ZM R K MARA K MARA K MARA K MARA KARAB K KARS KARS KASTAMONU KASTAMONU KASTAMONU KASTAMONU KASTAMONU KAYSER KAYSER KAYSER KIRIKKALE KIRIKKALE KIRIKKALE K TELL SK DAR KADIK Y KADIK Y KARTAL MAL...

Page 71: ...TEKN K KAZANCILAR T C G RKAN TEKN K ERKAM SO UTMA KARAN ELEKTR K ZCAN SO TEKFEN ELEKTR K AKSAN BOB NAJ ENER SO E EL F T CARET G M TEPE ELK TEKNO M HEND SL K EM N ELEKT KUTUPLAR SO ZB R ELK B L R T CA...

Page 72: ...KAN SO UTMA AYDIN ELEKTRON K EKO SO UTMA SEY TLER SO UTMA YILKAY SO UTMA ADA ELK EV ALETLER YILMAZLAR ELK TEKSAN ELK FIRAT ELK YARA IR SO ASAN SO UTMA K K T C B RL K ELK LTER ELEKTR K D YANA T CARET M...

Page 73: ...kaynaklanan hasar ve ar zalar 7 r n n tamir yap lacak yere nakliyesi s ras nda olu an hasar ve ar zalar Dikkat Yanl bak m ve temizleme durumunda cihaz n z garanti kapsam d na kar 1 Ortamdan kaynaklan...

Page 74: ...Notlar 26 Ufo Kullan m K lavuzu Garanti Belgesi...

Page 75: ......

Page 76: ...richtige in Betriebnahme und Wartung sind wichtig f r Sie und andere Personen die den W rmer benutzen werden Der Unterschied zwischen unseren Produkten UFO Line und UFO Star sind die Lebensdauer der...

Page 77: ...he Ma e 8 6 Betriebsanweisungen 9 6 1 UFO Line UFO Star 9 6 2 UFO Line Fernbedienung 10 6 2 1 Beschreibung der Funktionen der Fernbedienkn pfe 10 6 2 2 Bezeichnung und Funktionen der Darstellungen auf...

Page 78: ...Ger tes an eine leicht zug ngliche und sichtbare Steckdose B Montage an die Wand Sicherheitsabst nde gegen hohe Temperaturen und Feuerschutz Achtung Das Ger t darf nur horizontal benutzt werden es ka...

Page 79: ...eerdeten Steckdose an dem das Ger t angeschlossen werden soll muss zur Badewanne der Dusche dem Waschbecken oder anderen sanit ren Installationen einen Abstand von mindestens 1 00m haben D Reinigungs...

Page 80: ...r Verpackung des Ger tes werden mit sich wiederum in der Verpackung des Ger tes befindlichen 5X40 Holzschrauben mittels eines geeigneten Schraubendrehers an die Wand befestigt 4 Befestigen Sie die zwe...

Page 81: ...onen Achtung Nur eine Befestigung von 5 gew hrt eine Langlebigkeit FALSCH RICHTIG Sichere Abst nde Zur Sicherheit erforderliche Mindestabst nde Mindestabst nde zu Wandecken Mindestabstand zum Erw rmbe...

Page 82: ...ICHTIG DAS GER T SOLLTE IN EINEM RICHTOGEN WINKEL AUSGERICHTET WERDEN Da das Ger t vorrangig das Gebiet erw rmt auf das der Lichtstrahl f llt sollte vermieden werden dass der Strahl durch Scheiben Fen...

Page 83: ...Wickelraum Arbeitszimmer Gew chshaus Hobby R ume Schwimmbad B ros Versammlungsr ume Empfang Werkstatt Verkaufsr ume Gew chsh user Internet Cafe s Einkaufszentren Ausstellungsfl chen Innen und Au en Sc...

Page 84: ...UFO LINE 50 60 50 60 50 60 50 60 50 60 50 60 UFO S 12 UFO S 15 UFO S 18 UFO S 23 UFO S 30 110 120 110 120 220 230 220 230 220 230 1200 1400 1500 1700 1800 2000 2300 2500 2900 3200 19 19 19 19 19 10 1...

Page 85: ...llen des Thermostat Knopfes auf das erw nschte Niveau bewirkt dass das Ger t sich ein und ausschaltet Durch die Thermostateinstellung werden bei erw nschten Raumtemperaturen Energieeinsparungen gemach...

Page 86: ...Rauf Runter Stellt die Programme ein 3 Clock Uhr Stellt die Uhr ein 4 Timer On Einschaltzeiteinstellung Bewirkt dass das Ger t zur eingestellten Zeit sich einschaltet 5 Timer Off Ausschaltzeiteinstel...

Page 87: ...leitung Garantiezertifikat 11 Symbol Anzeige Leistungsniveaueinstellung Anzeige Zeiteinstellung Anzeige Einschaltzeit des Ger tes Anzeige Ausschaltzeit des Ger tes Zeigt die Restzeit bis zum Ausschalt...

Page 88: ...1 Stufe aktiviert 1 Um die Batterien einzusetzen drehen Sie die Fernbedienung um und entfernen Sie die Abdeckung des Batteriefaches und setzen entsprechend der Anweisung wie mit den Symbolen und darg...

Page 89: ...ste Um w hrend des Programms die Uhr Einstellfunktion zu berspringen dr cken Sie auf die Cancel L schen Taste ANMERKUNG Wenn w hrend der Uhr oder Ein und Ausschaltzeiteinstellungen die Tasten gedr ckt...

Page 90: ...mmierens zu l schen muss die Cancel Taste gedr ckt Wenn w hrend des Programmierens nicht innerhalb von 20 Sekunden auf die erforderliche Taste zum Speichern gedr ckt wird Clock Timer On Sleep und Time...

Page 91: ...pp Sensor aktiviert und w hrend auf dem Display der Er Schriftzug erscheint wird ein Warnton mit dem Buzzer ert nt Wenn dass Ger t in die normale Betriebsposition gebracht wird geht das Ger t auf stan...

Page 92: ...Gl hdraht Nutzungsdauer Stunden Plastik Abdeckung Stromkabell nge Fernbedienung Reflektor Blendspiegel Seitenreflektor Schutz Drahtk fig Betriebswiderstand Betriebsfrequenz Naturel Champagner Alumini...

Page 93: ...ei Jahre ausgewechselt werden Der Reflektor muss durch den zust ndigen technischen Dienst ausgewechselt werden und ein Original UFO Reflektor muss verwendet werden Die Sauberkeit des Reflektors sorgt...

Page 94: ...nicht die Funktionst chtigkeit der Sicherung und des Stromkabels muss kontrolliert werden Falls an der Steckdose kein Strom sein sollte muss ein Elektrotechniker gerufen werden 3 Es muss kontrolliert...

Page 95: ...Defekte und St rungen die auf dem Weg zur Reparaturstelle des Produktes entstanden sind Achtung Bei fehlerhafter Wartung und Reinigung wird Ihr Produkt au er Garantie gesetzt 1 Nicht Beachtung des St...

Page 96: ...Notizen 20 AUF DEUTSCH UFO Benutzungsanleitung Garantiezertifikat...

Page 97: ...Notizen UFO Benutzungsanleitung Garantiezertifikat 21 AUF DEUTSCH...

Page 98: ...Notizen 20 AUF DEUTSCH UFO Benutzungsanleitung Garantiezertifikat...

Page 99: ...halinde SUN Pazarlama r n n tamiri tamamlan ncaya kadar benzer zelliklere sahip ba ka bir mal t keticinin kullan m na tahsis edecektir Garanti kapsam na giren ar zan n tayini ve de i tirilecek par al...

Page 100: ...SUN Pazarlama Elk Makina San Tic Ltd ti...

Reviews: