ADDITIONAL TROUBLESHOOTING (0-10V MODELS ONLY)
Problem
Probable Causes
Remedy
0-10V Version unit is dead -
no light output - but LED
indicator on light source is
illuminated.
No 0-10V dimming to unit
(0V= LED Off)
Refer to manual diagram for
correct termination.
Carry out continuity check.
Carry out voltage / polarity
check
0-10V cable fault
Controller fault
Carry out voltage / polarity
check at controller.
Repair / replace as necessary
0-10V LED PCB failure
Replace 0-10V PCB
No 0-10V signal present
Controller off or failed
Check controller. Ensure 0-
10V signal present
0-10V cable faulty
Carry out voltage and
polarity check on mini XLR
plug. Repair as necessary
Universal Fibre Optics
13
Please complete troubleshooting procedures before returning unit to us for further investigation.