TROUBLESHOOTING
13
UFO
LIGHTING
Problem
Possible Cause(s)
Remedy
Unit is dead
no light output
but LED
indicator on
light source is
illuminated.
No 0
10V dimming to unit
(0V= LED O
ff
)
Refer to manual diagram for
correct termina
ti
on.
Carry out con
ti
nuity check.
Carry out voltage / polarity
0
10V cable fault check
0
10V cable fault
Controller fault
Carry out voltage / polarity
check at controller.
Repair / replace as necessary
0
10V LED PCB failure
Replace 0
10V PCB
No 0
10V signal
present
Controller o
ff
or failed
Check controller. Ensure 0
10V signal present
0
10V cable faulty
Carry out voltage and
polarity check on mini XLR
plug. Repair as necessary
ADDITIONAL
PROCEDURES
FOR
0-10
V
MODELS
ONLY
Note:
please complete relevant troubleshooting procedures before returning the unit to us for
further investigation.