CONNECTIONS
As well as the standard XLR connectors for DMX connection, the Cube is also fitted with RJ45
connectors which also offer DMX capability. Details of these are below:
Pin No:
1
2
3
4
5
6
7
8
Color
White
Orange
Orange
White
Green
Blue
White
Blue
Green
White
Brown
Brown
Func
ti
on
DMX+
DMX
Spare
Spare
Spare
Spare
Ground
Ground
XLR =
Pin 3
Pin 2
Pin 1
Pin 1
Note:
It is recommended that a 120ohm terminating resistor be connected across DMX+ and
DMX- on the last illuminator on the DMX universe or cable run
INSTALLATION
CUBE
USER
GUIDE
4