![UFESA DH4020 Instruction Manual Download Page 22](http://html1.mh-extra.com/html/ufesa/dh4020/dh4020_instruction-manual_3237316022.webp)
APPLIANCE STORAGE FOR EXTENDED
PERIODS OF TIME
If the appliance is not used for an extended period of
time:
●
Turn off the appliance and unplug the power cord
(13)
from the wall outlet.
●
After one day after turning the appliance off, empty
the water tank
(5)
.
●
Clean the housing of the dehumidifier
(2)
, the air
inlet
(7)
and outlet
(3)
grille, and the air filter
(10)
.
●
Wind the power cord
(13)
and secure it to the
appliance using the bracket
(14)
.
●
Put the appliance in a plastic bag.
●
Keep the dehumidifier in a vertical position, in a dry
and well-ventilated place.
Troubleshooting
WARNING AND ERROR CODES
The occurrence of some issues during operation is indicated on the appliance display.
Warning codes
Warning code
Indicator name
Solution
P1
Automatic defrost function is enabled.
Do not turn off the appliance – let the
defrosting process continue until the end.
P2
The water tank is full or incorrectly installed.
Empty the water tank or install it properly.
Error codes
Error code
Error name
Solution
AS
Humidity sensor error.
Disconnect the appliance from the power
outlet. Then reconnect it to the power
outlet. If the problem persists, contact
a professional service centre.
E3
System error.
ES
Temperature sensor error.
EC
Leakage of coolant.
Contact a professional service centre.
Summary of Contents for DH4020
Page 61: ...24 35 5 2002 96 EC...
Page 62: ...P1 P2 AS E3 ES EC...
Page 63: ...3 10 11 12 4 2 3 7 5 5 30 10 14 9 1 M 10 2 3 4 5 13 5 7 2 10 3 13 14...
Page 64: ...8 P2 3 5 8 P2 5 1 2 3 K 3 13 5 12 1 13 5 2 11 L...
Page 67: ...13 1 5 P2 8 F on off 2 J G C D E modo B 5...
Page 69: ...AC 5 50 LWA 35 5 80 30 20 135 52 3 150...
Page 70: ...UFESA 8 AR...