International Symbols

C o n t rols and Indicators

DANGER!

DO NOT

exceed 700 volts AC or DC. Exceeding this value may result in

serious injury or equipment damage!

DANGER!

Voltage measured from phase to phase may be much higher than the
specified voltage. Some multi-phase systems are specified relative to
the voltage measured from ground to a single phase.

DANGER!

DO NOT

remove the ECT600A from its protective boot or use when

wet. The boot provides insulation from measured voltage. Moisture
reduces insulation’s properties.

WARNING!

Inspect this instrument prior to use for cracks or damage to the housing,
f rayed or cut insulation, modification, or any other discre p a n cy to the unit.

DO NOT

use your ECT600A if any of these conditions exist! Replace the

instrument or have it re p a i red at a qualified facility.

WARNING!

Probe tips are extremely sharp! Store and transport this instrument in 
a manner that reduces risk of contact with the probes tips. 

DO NOT

attempt to catch the unit if it is dropped.

Verify your instrument is functioning properly:

Each time you 

use your ECT600A, verify it is functioning properly by following the
instructions below on a know good voltage source. This is particularly
important when using this instrument to ensure wiring is safe to touch.

Introduction

The ECT600A detects both voltage and continuity. The bright panel of 
Light Emitting Diode (LED) indicators provides a quick and sure display of
measured voltage, ranging from 12 to 600 volts AC or DC. A loud, clear
audio tone sounds to give you a quick indication that voltage or continuity
is present even if you can’t see the display.

The continuity feature sounds at a distinctive tone when the ECT600A finds
a path for current to flow between two wires or other probed points.

With no batteries to replace, your ECT600A is ready to go when you are.

Features include

• Quick single-probe AC checks
• LED indication of voltage level
• Loud audible tone
• Continuity tester
• AC and DC voltage measurement
• No battery needed

Safety Notes

Before using this meter, read all safety information carefully. In 
this manual the word 

"WARNING"

is used to indicate conditions 

or actions that may pose physical hazards to the user. The word 

"CAUTION"

is used to indicate conditions or actions that may 

damage this instrument.

WARNING!

Exceeding the specified limits of this meter is dangerous and can
expose the user to serious or possibly fatal injury.

• Read the safety precautions associated with the equipment being 

tested and seek assistance or advice when performing 
unfamiliar tasks.

• Keep your fingers away from the test lead metal probe contacts 

and bus-bars when making measurements. Always grip the 
instrument and test-lead behind the hand guards (molded into 
the probe).

• In the event of electrical shock, ALWAYS bring the victim to 

the emergency room for evaluation, regardless of the victim’s
apparent recovery. Electrical shock can cause an unstable heart
rhythm that may need medical attention.

ECT600A-MAN    

P. 1

Summary of Contents for ECT600A

Page 1: ...1 800 547 5740 Fax 503 643 6322 www ueitest com email info ueitest com ECT600A INSTRUCTION MANUAL ...

Page 2: ...provides a quick and sure display of measured voltage ranging from 12 to 600 volts AC or DC A loud clear audio tone sounds to give you a quick indication that voltage or continuity is present even if you can t see the display The continuity feature sounds at a distinctive tone when the ECT600A finds a path for current to flow between two wires or other probed points With no batteries to replace yo...

Page 3: ...the unit exposed to a voltage source 100 to 700 volts for at least 5 seconds Typically the instrument will retain its charge for at least 30 minutes without being used and will sustain the continuity tone for more than one minute if recently charged Charging is required for all audio tone dependent functions Testing For Continuity Continuityindicates that current can flow from one point to another...

Page 4: ...ble parts In the event your instrument is physically damaged or does not function properly please return the instrument to UEi following the warranty and service instructions Specifications Operating range ECT600A MAN P 3 Voltage 12 to 600 Volts DC or AC at 50 60 Hz Maximum voltage input 700 V DC or AC ground to phase Single probe sensitivity 100 700 V AC audio only Continuity Audio tone from 0 to...

Page 5: ...d to implied warranties of merchantability and fitness for a particular purpose are limited to the express warranty UEi shall not be liable for loss of use of the instrument or other incidental or consequential damages expenses or economic loss or for any claim or claims for such damage expenses or economic loss A purchase receipt or other proof of original purchase date will be required before wa...

Reviews: