The DT200 is a portable, battery operated temperature measuring
device. With its triple display screen, it allows you to measure two
inputs simultaneously, and record critical time stamped information.
Since the DT200 accepts type J, K, or T probes, you can use the probes
you have without changing your existing process technology. The backlit
display makes reading the LCD easy even in low light areas.

Features include

• -328 to 2498˚F (-200 to 1370˚C)
• Triple display
• Backlit display
• Dual input
• Differential temperature (

T)

• Relative function displays temperature change
• Accepts K, J and T thermocouples
• Data hold

Safety Notes

Before using this meter, read all safety information carefully. In this
manual the word 

"WARNING"

is used to indicate conditions or actions

that may pose physical hazards to the user. The word 

"CAUTION"

is

used to indicate conditions or actions that may damage this instrument.

Safety precautions

These are a few common safety practices for those working around
temperature critical environments:

•   Follow the manufacturer’s maintenance procedures when 

servicing equipment

•   Place ONLY thermocouples (type K, J, or T) in the DT200 

thermocouple ports

•   Make sure your DT200 is set for the proper thermocouple type 

you are using

•   Be sure the thermocouple you use can withstand the temperature 

extreme it may be exposed to in your service task

•   Properly maintain your DT200 and calibrate it regularly

International Symbols

C o n t rols and Indicators

1.

Power Switch:

Powers instrument on and off.

2.   

Hold/Relative Switch:

Freezes primary screen data or 

establishes a relative zero for the primary screen information.

3.   

T1-T2 Switch:

Toggles screen information from T1 (Primary) 

and T2 (Secondary) to T2 Primary and T1 Secondary then to 
T1-T2 (differential) on Primary and alternating T1 and T2 
temperatures on Secondary.

4.   

Back Light Switch:

Turns back light on. Automatically turns 

off in 30 seconds.

5.   

K/J/T Thermocouples Select Switch:

Selects proper input 

reference for thermocouple in use (T1 and T2 must be the 
same type).

6.   

˚F/˚C Mode Select Switch:

Toggles display data from degrees 

Celsius to degrees Fahrenheit.

7.

Record Mode Select Switch:

Starts record mode (relative 

clock), displays maximum and minimum temperatures 
recorded on the Primary screen along with the relative time 
they were recorded.

8.   

Thermocouple Ports:

Positive and negative polarized plugs for 

the thermocouple probes used (Blade type); T1 on the left, T2 
on the right.

9.   

LCD Displays:

Displays three screens of function and data 

information.

10.  

Primary Data Screen:

Displays T1, T2, or T1 minus T2 

(temperature differential - TD) or a relative zero of T1, T2 or TD.

11.

Secondary Data Screen:

Displays time in hours and minutes 

when Record is pressed and the relative time that NIM or MAX data
was recorded.

12.  

Relative Clock Screen:

Displays time in hours and minutes when 

record is pressed and the relative time that MIN or MAX data 
was recorded.

8

9

12

5

1

6

10

11

7

2

3

4