background image

WARRANTY 

The DM525 is warranted to be free from defects in materials and workmanship for a period of 2 years from the date of 
purchase. If within the warranty period your instrument should become inoperative from such defects, the unit will be 
repaired or replaced at UEi’s option. This warranty covers normal use and does not cover damage which occurs in shipment 
or failure which results from alteration, tampering, accident, misuse, abuse, neglect or improper maintenance. Batteries and 
consequential damage resulting from failed batteries are not covered by warranty.

Any implied warranties, including but not limited to implied warranties of merchantability and fitness for a particular 
purpose, are limited to the express warranty. UEi shall not be liable for loss of use of the instrument or other incidental or 
consequential damages, expenses, or economic loss, or for any claim or claims for such damage, expenses or economic loss.

A purchase receipt or other proof of original purchase date will be required before warranty repairs will be rendered. 
Instruments out of warranty will be repaired (when repairable) for a service charge 

This warranty gives you specific legal rights. You may also have other rights, which vary from state to state.

DISPOSAL

 CAUTION:

  

This symbol indicates that equipment and its accessories shall be subject to separate collection and 

correct disposal.

CLEANING

Periodically clean your meters’ case using a damp cloth. DO NOT use abrasive, flammable liquids, cleaning solvents, or strong 
detergents as they may damage the finish, impair safety, or affect the reliability of the structural components.

STORAGE

Remove the batteries when instrument is not in use for a prolonged period of time. Do not expose to high temperatures or 
humidity. After a period of storage in extreme conditions exceeding the limits mentioned in the General Specifications section, 
allow the instrument to return to normal operating conditions before using it.

Copyright © 2018 Kane USA Inc. All Rights Reserved. 17490  0118

www.calcert.com

[email protected]

1.800.544.2843

0

5

10

15

20

25

30

Summary of Contents for DM525

Page 1: ...A mA 10A MAX FUSED 400mA MAX FUSED MAX CAT IV 600V CAT III 1000V DM525 mV F C REL Hz Hz W PF 0 10 20 30 40 50 60 LINK INSTRUCTION MANUAL ENGLISH DM525 True RMS 1000V Digital Multimeter w Temperature...

Page 2: ...apacitance 10 AC DC Microamps 6000 A 11 AC DC Milliamps 400mA 11 AC DC Amps 10A 12 Temperature C F 13 Low Z Low Impedance Filter 13 Frequency Duty Cycle 14 Relative REL Mode 14 Wireless Capability 14...

Page 3: ...FICATIONS Operating Temperature 32 to 122 F 0 to 50 C Storage Temperature 44 to 122 F 20 to 50 C Operating Humidity 75 max Operating Altitude 6561 ft 2000m Display 6 000 Back light Yes Over range OL i...

Page 4: ...national and local safety codes Use proper personal protective equipment PPE to prevent shock and arc blast injury where hazardous live conductors are exposed Always turn off power to a circuit or as...

Page 5: ...In the V A mA or Amps function either select AC DC or change to manual ranging before pressing this button to enter MAX MIN mode Press repeatedly to alternate between Maximum and Minimum readings Pre...

Page 6: ...dicator Maximum CAT Rating for fused input jacks Multifunction input port used for measuring AC or DC volts AC or DC mV Temperature Hertz Duty Cycle Watts Resistance Continuity Diode Capacitance AC or...

Page 7: ...8 dgts 2 0 20 dgts 0 1mV 600V Auto selection mode is not available DC MILLIVOLTS Ranges Accuracy Resolution Overload Protection 600 0mV 0 2 5 dgts 0 1mV 600V Auto selection mode is not available Note...

Page 8: ...GE SEL Temp A True RMS MIN MAX HOLD FAST Low Z V Low Z Apo A mA A A mA 10A MAX FUSED 400mA MAX FUSED MAX CAT IV 600V CAT III 1000V DM525 mV F C REL Hz Hz W PF 0 10 20 30 40 50 60 LINK Open Circuit Vol...

Page 9: ...HOLD SEL Ranges Accuracy Resolution Overload Protection 10 00nF 2 0 5 dgts 0 01nF 600V 100 0nF 0 1nF 1 000 F 2 5 5 dgts 0 001 F 10 00 F 0 01 F 100 0 F 0 1 F 9999 F 3 0 5 dgts 1 F Capacitance Open Dio...

Page 10: ...m sensitivity 50 A DC auto selection mode only ACmA Ranges Accuracy Burden Voltage Resolution Overload Protection 45Hz to 500Hz 500Hz to 5kHz 60 00mA 1 0 5 dgts 1 5 10 dgts 2mV mA 0 01mA 600mA 1000V F...

Page 11: ...ad for 30 seconds max DC A Ranges Accuracy Burden Voltage Resolution Overload Protection 6 000A 1 0 5 dgts 0 02V A 0 001A 11A 1000V Fast fuse 10 00A 0 01A Minimum sensitivity 500mA auto selection mode...

Page 12: ...scale between Fahrenheit and Celsius Features MIN MAX HOLD SEL F Ranges Accuracy Resolution Overload Protection 328 to 999 F 1 5 3 6 F 0 1 F 600V 1000 to 2462 F 1 5 3 0 F 1 F C Ranges Accuracy Resolu...

Page 13: ...ution Overload Protection 99 99Hz to 999 9kHz 0 05 3 dgts 0 01Hz to 0 1kHz 600V Duty Cycle Ranges Accuracy Overload Protection 1 0 to 99 0 0 1 3 dgts 0 2 per kHz 600V Frequency Duty Cycle RANGE SEL Te...

Page 14: ...rrent clamp transformers The meter automatically selects the range which allows for the highest possible resolution of the applied quantities NOTE If the meter activates a measuring range which is too...

Page 15: ...such as standard wall outlets Take care not to lose the shields WARNING Test lead category protections apply only to test leads and should not be confused with the meter s speci c CAT rating Observe t...

Page 16: ...to activate wireless BT Open App Meter will connect automatically Menu Press to connect disconnect and access settings Settings General settings adjust button sound vibrate and refresh rate Recording...

Page 17: ...y mm dd hh mm ss Functions are noted underneath respectively AMP AMP TOP BOTTOM Display Press button for summary Press button for sample data Press button to export data via email in csv png or jpg fo...

Page 18: ...ference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television rec...

Page 19: ...ase receipt or other proof of original purchase date will be required before warranty repairs will be rendered Instruments out of warranty will be repaired when repairable for a service charge This wa...

Reviews: