Limited Warranty

The CO 91 is warranted to be free from defects in materials and workmanship for a period of
three years (two years on sensor) from the date of purchase. If within the warra n ty period
your instrument should become inoperative from such defects, the unit will be repaired or
replaced at UEi’s option. This warra n ty covers normal use and does not cover damage which
occurs in shipment or failure which results from alteration, tampering, accident, misuse,
abuse, neglect or improper maintenance. Batteries and consequential damage resulting from
failed batteries are not covered by warra n ty. 

Any implied warranties, including but not limited to implied warranties of merchantability
and fitness for a particular purpose, are limited to the express warranty. UEi shall not be
liable for loss of use of the instrument or other incidental or consequential damages,
expenses, or economic loss, or for any claim or claims for such damage, expenses or 
economic loss. A purchase receipt or other proof of original purchase date will be required
before warra n ty repairs will be rendered. Instruments out of warra n ty will be repaired (when
r e p a i rable) for a service charge. Return the unit postage paid and insured to:

1-800-547-5740 • FAX: (503) 643-6322

Service: (800) 308-7709

www.ueitest.com • Email: [email protected]

This warranty gives you specific legal rights. You may also have other rights which vary from
state to state.

CO91

Carbon Monoxide Analyzer

Copyright © 2004 UEi      

CO91-MAN  7/04

Summary of Contents for C091

Page 1: ...1 800 547 5740 Fax 503 643 6322 www ueitest com email info ueitest com CO91 INSTRUCTION MANUAL ...

Page 2: ... meter must only be used in well ventilated locations by trained and competent persons after due consideration of all the potential hazards International Symbols Controls and Indicators 1 Power Push button Press button to switch the unit ON in fresh air outside the property about to be tested This lets the meter auto calibrate its sensors properly When turned on the meter beeps four times and disp...

Page 3: ...e and temperature on its bottom line if you turn the rotary dial to TEMP and push the DOWN button until CO is displayed on the top line Use the UP DOWN ENTER keys to change settings such as time and date when the rotary dial is turned to MENU 3 PRINT BACKLIGHT button Press and release PRINT BACKLIGHT quickly to switch backlight on or off Press for more than 1 second before releasing to start the m...

Page 4: ...nsors When the meter readings return to ambient levels switch off The meter counts down from 30 before switch off with the pump running to self clean its sensors Empty the water trap and check filter prior to storage and next use Troubleshooting Specifications General specifications CO91 MAN P 3 UEI CO91 503 644 8723 06 26 02 14 27 SMOKE NATURAL GAS CO PPM 00 CO MAX PPM TEMP F If I See This Malfun...

Page 5: ...r fire as they may expose and cause injury 7 Replace battery compartment cover Electromagnetic Compatibility EMC European Council Directive 89 336 EEC requires electronic equipment not to generate electromagnetic disturbances exceeding defined levels and have adequate immunity levels for normal operation Specific standards applica ble to this meter are stated below As there are electrical products...

Page 6: ... not limited to implied warranties of merchantability and fitness for a particular purpose are limited to the express warranty UEi shall not be liable for loss of use of the instrument or other incidental or consequential damages expenses or economic loss or for any claim or claims for such damage expenses or economic loss A purchase receipt or other proof of original purchase date will be require...

Reviews: