IMTX200-03
www.ueonline.com
Dimensions
Dimensional drawings for all models may be found at www.ueonline.com
Pressure Connection Chart
Code
Description
Hex
“A”in
Length
“B”in [mm]
1
1/4” NPT (female)
15/16
0.54 [13.7]
2
1/2” NPT (female)
1-3/8
1.01 [25.7]
3
1/2” NPT (male)
15/16
1.26 [32.0]
4
HF4 Autoclave (female)
15/16
0.54 [13.7]
5
FH6 Autoclave (female)
1-3/8
0.90 [22.9]
6
LF4 Autoclave (female)
15/16
0.54 [13.7]
7
LF6 Autoclave (female)
15/16
0.65 [16.5]
8
1/4” NPT (male)
15/16
0.97 [24.6]
9
7/16-20 SAE (female)
15/16
0.54 [13.7]
A
G-1/4 (female)
15/16
0.54 [13.7]
B
G-1/2 (female)
1-3/8
1.01 [25.7]
C
7/16-20 SAE (male)
15/16
0.77 [19.6]
D
HM4 Autoclave (male)
15/16
1.10 [27.9]
E
HM6 Autoclave (male)
15/16
1.29 [32.8]
F
LM4 Autoclave (male)
15/16
1.18 [30.0]
G
LM6 Autoclave (male)
15/16
1.32 [33.5]
H
G-1/4 (male)
15/16
1.03 [26.2]
J
G-1/2 (male)
1-3/8
1.78 [45.2]
Wire Color Coding
Red
+ VDC
Black
- VDC
Green
Earth Ground
Blue
Voltage (VDC) Output
OR M20 (METRIC)
03
=
0 to 15 psis
04
=
0 to 30 psis
05
=
0 to 50 psis
06
=
0 to 100 psis
07
=
0 to 250 psis
08
=
0 to 500 psis
09
=
0 to 1000 psis
17
=
0 to 1500 psis
18
=
0 to 2000 psis
10
=
0 to 2500 psis
19
=
0 to 3000 psis
11
=
0 to 5000 psis
20
=
0 to 6000 psis
12
=
0 to 7500 psis
13
=
0 to 10,000 psis
14
=
0 to 15,000 psis
15
=
0 to 20,000 psis
16
=
0 to 25,000 psis
Pressure Ranges