Pressure Connection Chart

Code

Description

Hex

“A”in

Length

“B”in [mm]

1

1/4” NPT (female)

15/16

0.54 [13.7]

2

1/2” NPT (female)

1-3/8

1.01 [25.7]

3

1/2” NPT (male)

15/16

1.26 [32.0]

4

HF4 Autoclave (female)

15/16

0.54 [13.7]

5

FH6 Autoclave (female)

1-3/8

0.90 [22.9]

6

LF4 Autoclave (female)

15/16

0.54 [13.7]

7

LF6 Autoclave (female)

15/16

0.65 [16.5]

8

1/4” NPT (male)

15/16

0.97 [24.6]

9

7/16-20 SAE (female)

15/16

0.54 [13.7]

A

G-1/4 (female)

15/16

0.54 [13.7]

B

G-1/2 (female)

1-3/8

1.01 [25.7]

C

7/16-20 SAE (male)

15/16

0.77 [19.6]

D

HM4 Autoclave (male)

15/16

1.10 [27.9]

E

HM6 Autoclave (male)

15/16

1.29 [32.8]

F

LM4 Autoclave (male)

15/16

1.18 [30.0]

G

LM6 Autoclave (male)

15/16

1.32 [33.5]

H

G-1/4 (male)

15/16

1.03 [26.2]

J

G-1/2 (male)

1-3/8

1.78 [45.2]

Wire Color Coding

Red

+ VDC

Black

- VDC

Green

Earth Ground

Blue

Voltage (VDC) Output

OR M20 (METRIC)

03

=

0 to 15 psis

04

=

0 to 30 psis

05

=

0 to 50 psis

06

=

0 to 100 psis

07

=

0 to 250 psis

08

=

0 to 500 psis

09

=

0 to 1000 psis

17

=

0 to 1500 psis

18

=

0 to 2000 psis

10

=

0 to 2500 psis

19

=

0 to 3000 psis

11

=

0 to 5000 psis

20

=

0 to 6000 psis

12

=

0 to 7500 psis

13

=

0 to 10,000 psis

14

=

0 to 15,000 psis

15

=

0 to 20,000 psis

16

=

0 to 25,000 psis

Pressure Ranges

Summary of Contents for TX200

Page 1: ...ducts do not have any field replaceable parts Any substitution of components may impair suitability for Class I Division 1 TX200 Pressure Transmitter The epoxy resin shall not be subjected to a temperature greater than 125 C Part I Installation Tools Needed Adjustable Wrench Mounting Always locate units where shock vibration and ambient temperature fluctuations are minimal Do not mount in ambient ...

Page 2: ...l scale pressure range Pcal Cal is the amount of pressure simulated by turning the shunt cal on The Cal is engraved on the TX200A housing and written on the Certificate of Calibration Pcal is the full scale pressure range the user is adjusting to Vzero is the output of the voltage VDC out model with no pressure applied VFSO is the full scale output in volts of a voltage VDC out model Example For a...

Page 3: ...16 0 54 13 7 B G 1 2 female 1 3 8 1 01 25 7 C 7 16 20 SAE male 15 16 0 77 19 6 D HM4 Autoclave male 15 16 1 10 27 9 E HM6 Autoclave male 15 16 1 29 32 8 F LM4 Autoclave male 15 16 1 18 30 0 G LM6 Autoclave male 15 16 1 32 33 5 H G 1 4 male 15 16 1 03 26 2 J G 1 2 male 1 3 8 1 78 45 2 Wire Color Coding Red VDC Black VDC Green Earth Ground Blue Voltage VDC Output OR M20 METRIC 03 0 to 15 psis 04 0 t...

Page 4: ...Preventative maintenance and periodic testing is necessary for critical appli cations where damage could endanger property or personnel Electrical ratings stated in literature and on nameplate must not be exceed ed Overload on a switch can cause damage even on the first cycle Wire unit according to local and national electrical codes using wire size recom mended in installation sheet Do not mount ...

Reviews: