UE 12 Series Installation And Maintenance Instructions Download Page 3

IMP12-14

www.ueonline.com

3

Dimensions

dimensional drawings for all models may be found at www.ueonline.com 

Standard Configuration

 

PRESSuRE SWITCH / CoNNECTIoN CHART

 

dimension “a” 

dimension “b” 

dimension “c”

Type Description 

Inches 

mm Inches 

mm Inches 

mm

1/2” nPt (female) 

4.4 

111.1 

0.7 

16.5 

1-1/16  27.0

3, 5 

1/2” nPt (female) 

4.4 

111.1 

0.6 

15.2 

1-1/16  27.0

4, 6, 8 

1/4” nPt (female) 

4.4 

111.1 

0.6 

15.2 

1-1/16  27.0

7, 9 

1/2” nPt (female) 

4.0 

100.3 

1.6 

40.6 

1-1/8 

28.6

P0-P9 

1/4”nPt (female) 

4.4 

111.1 

1.0 

25.4 

1-1/16  27.0

w1-w2 

1/2”nPt (female) 

4.0 

100.3 

2.2 

55.9 

1-1/16  27.0

w3-w4 

1/2”nPt (female) 

4.0 

100.3 

1.7 

42.9 

1-1/16  27.0

k1-k3 

1/8”nPt (female) 

4.4 

111.1 

1.7 

42.9 

n/a 

n/a

k4-k6 

1/8”nPt (female) 

4.4 

111.1 

1.8 

44.5 

n/a 

n/a

Option

 

Description

M511 

1/4” nPt (male) 

 

 

1.1 

27.9 

1-1/16  27.0

M521 

lf4 autoclave 1/4” (female)   

 

1.2 

29.7 

1-1/16  27.0

M522 

lM4 autoclave 1/4” (male) 

 

 

1.4 

34.8 

1-1/16  27.0

M523 

lf6 autoclave 3/8” (female)   

 

1.4 

36.1 

1-1/16  27.0

M524 

lM6 autoclave 3/8” (male) 

 

 

1.5 

38.4 

1-1/16  27.0

M525 

hf4 autoclave 1/4” (female)   

 

1.2 

29.7 

1-1/16  27.0

M526 

hM4 autoclave 1/4” (male) 

 

 

1.3 

32.8 

1-1/16  27.0

M527 

hf6 autoclave 3/8” (female)   

 

1.4 

36.1 

1-1/16  27.0

M528 

hM6 autoclave 3/8” (male) 

 

 

1.5 

37.6 

1-1/16  27.0

xP112 

1/2” nPt (female) 

 

 

0.6 

15.2 

1-1/16  27.0

xP113 

1/2” nPt (female) 

 

 

0.6 

15.2 

1-1/16  27.0

xP114 

1/4” nPt (female) 

 

 

0.6 

15.2 

1-1/16  27.0

xP115 

1/4” nPt (female) 

 

 

0.6 

15.2 

1-1/16  27.0

Type 2, 3, 5

Type 4, 6, 8, P0-P9

Type 7, 9

Type K4-K6

Type K1-K3

Types K1-K3 and K4-K6 shown with mounting bracket attached

A

B

DIA.

1-1/4 [31.7mm] 

FACTORY SEALED 

LEADWIRES 72" LG.

E/C: ST/ST

1/2 NPT OR 

M20 (METRIC)

ADJUSTMENT 

ACCESS COVER

WRENCH DIM “C”

SLOTTED ADJUSTMENT SCREW,

(TURN SCREW CLOCKWISE TO INCREASE SET POINT)

DIA.

1 1/4 [31.7mm]

ADJUSTMENT 

ACCESS COVER
SLOTTED ADJUSTMENT SCREW,

(TURN SCREW CLOCKWISE TO INCREASE SET POINT)

FOUR TERMINAL DIN CONNECTOR

(CONFORMS TO DIN 43650, FORM A)

2-3/4 [69.7mm]

1-1/2

[38.1mm] DIA.

TERMINALS

#1     COMMON

#2     NORMALLY CLOSED

#3     NORMALLY OPEN

          GROUND

options M522, 

M524, M526, 

M528

  Male autoclave 

feMale autoclave

Note:  

does not meet div. 1 or 2, 

or atex requirements.

Figure 3

option M511

(1/4” NPT male)

options XP112, XP113 

(1/2” NPT female)

options XP114, XP115 

(1/4” NPT female)

Differential Pressure Connections

option M515 DIN Connection

Figure 4

Pressure Connections

options M521, 

M523, M525, 

M527

Type W

Summary of Contents for 12 Series

Page 1: ...t is installed This product is suitable for use in Class I Divisions 1 2 Groups a B C and D Class II Divisions 1 2 Groups E f and G class III or non hazardous locations only 50 C 58 F Tamb 80 C 176 F Enclosure Type 4X This product is ATEX and iecex certified for equipment category 2 Suitable for appropriate use in gas zone 1 and dust zone 21 applications EN 60079 0 2012 EN 60079 1 2007 EN 60079 31...

Page 2: ...ot be exceeded overload on a switch can cause failure on the first cycle DIN connector option M515 figure 4 is not approved for Class I Div 1 Hazardous Locations Flameproof atmospheres for atex installation an External grounding screw option M460 is required for non metallic conduit systems SEE figure 2 for atex installation in hazardous locations tHE WIRING TO THE PRESSUrE SWITCH MUST ONLY BE CON...

Page 3: ... 1 16 27 0 M526 HM4 autoclave 1 4 male 1 3 32 8 1 1 16 27 0 M527 HF6 Autoclave 3 8 female 1 4 36 1 1 1 16 27 0 M528 HM6 Autoclave 3 8 male 1 5 37 6 1 1 16 27 0 XP112 1 2 NPT female 0 6 15 2 1 1 16 27 0 XP113 1 2 NPT female 0 6 15 2 1 1 16 27 0 XP114 1 4 NPT female 0 6 15 2 1 1 16 27 0 XP115 1 4 NPT female 0 6 15 2 1 1 16 27 0 Type 2 3 5 Type 4 6 8 P0 P9 Type 7 9 Type K4 K6 Type K1 K3 Types K1 K3 a...

Page 4: ...allation sheet Do not mount unit in ambient temp exceeding published limits LIMITED WARRANTY Seller warrants that the product hereby purchased is upon delivery free from defects in material and workmanship and that any such product which is found to be defective in such workmanship or material will be repaired or replaced by Seller Ex works Factory Watertown Massachusetts INCOTERMS provided howeve...

Reviews: