11
THE YELLOW STORE BUTTON
TO STORE A READING
Press the yellow Store button. This puts the instrument in the data storage mode. In the data
storage mode, the display panel will change.
The Storage Location is shown in the upper left corner. There are 400 Storage Locations numbered
001 to 400. If the Storage Location has no data in it, the display will show: “NOT USED”.
If there has been information stored in the selected location, the upper section of the display will
indicate that information. The text field (if previously selected), Time, Date, Decibel, Frequency and
Operation Mode “R”, “S”, “P” (RO, SO, or PO with offset Value in the Offset Mode) will blink and
alternate (scroll). The text field, if previously selected in the Set-Up Mode, may be used to record
notes or codes.
The lower left corner of the display indicates the current
decibel level selected for storage.
The lower right of the display indicates the current
frequency selected for storage.
The lower right corner of the display indicates the
Operation Mode “R”, “S” or “P”, RO, SO, or PO.
TO STORE THE READING
Press the Store Button again and the data will be stored and displayed on top.
TO OVERWRITE DATA OR TO ENTER DATA IN A NEW LOCATION
Press the yellow Store button to enter the data storage mode.
Spin the Sensitivity Dial until the desired storage location is displayed on the screen
Press the yellow Store button to store the new information in that location and proceed as
described above.
To return to the operation mode, Click the Sensitivity Control Dial.
NOTE:
When using the Ultratrend software it is possible to enter a new reading that is out of
sequence by spinning to the last unused memory location (if all 400 locations are not filled) and
entering the data as described above. Following instructions in Ultratrend DMS, a new
sequential order can be updated to include the new item(s) for future inspections.
Data Storage Mode
Display