VALVE INSPECTION
Ultraprobe 10,000SD
-
Valve Inspection:
How To Guide
NOTE:
UE DMS Software available for download at
www.uesystems.com
SAFETY: WRIST STRAP WORN ALL TIMES
A, B, C, D, AND SOMETIMES E METHOD
The
A,B,C,D And Sometimes E Method
is a Fast, and
Easy Way to Determine
Not Only
the Position of the
Valve, But the Condition of the Valve. This Method
is Utilized to
Confirm
the Source of Detected
Turbulence
. This Simplistic Method Allows for
Consistent, Repeatable Testing.
1. Test Point “
A
” is
Three Times (3x) the Diameter
of the Piping
Away From the Valve On the Upstream
Side.
2. Test Point “
B
” is
One Times (1x) the Diameter of
the Piping
Away From the Valve On the Upstream
Side.
3. Test Points “
C
” and “
D
”
Mirror Test Points “A”
and “B” On the Downstream Side
of the Valve.
A
B
D
C
3 x Pipe Diameter
3 x Pipe Diameter
2 x PD
1 x PD
2 x PD
1 x PD