2. Safety Instructions - dos and don‘ts

The following guidelines shall help minimize the risk of 

injury by fire or ele

ctric shock.

1. Read and understand these safety notes before using 

the device and keep them in a safe place.
2. All warnings, instructions and additional texts on the 

device are equally important.
3. The device may cause permanent hearing loss. Do not 

operate it at a high volume levels or at levels that are 

uncomfortable for long periods of time.
4. The device is designed for use in moderate climate and 

shall be operated free-standing.
5. The device should be installed in a safe place and secu-

red against falling over.
6. The device should be installed near the socket outlet 

thus disconnection the device from mains should be easi-

ly accessible. 

7. The device should be located away from heat sources 

such as radiators, heat registers or other products that 

produce heat.
8. The device should not be installed or used close to

water or if you are wet yourself. 

9. The device should not be installed or used close to 

strong electromagnetic fields such as large mains trans

-

formers, revolving machines, neon illumination etc.
10. Pay attention to an unhindered air circulation around 

the amp. Never obstruct air vents or grilles.
11. Do not expose the device to sudden changes in tempe-

rature to avoid malfunction or damage due to moisture 

condensation inside. Secure the device to dry out comple-

tely before use again.
12. In keeping with the EMV regulations cables with shiel-

ding and correctly fitted connectors must be used for all 

signal connections.

ATTENTION

CAUTION

RISK OF ELECTRIC  SHOCK - DO NOT OPEN

RISQUE DE CHOC ELECTRIQUE

NE PAS OUVRIR

The lightning flash with the arrow head symbol within an

equilateral triangle is intended to alert the user to the

presence of uninsolated „dangerous voltage“ within this

product’s enclosure that may be of sufficient magnitude

to constitute a risk of electric shock to persons.

The exclamation point within an equilateral triangle is

intended to alert the user to the presence of important

operating and maintenance (servicing) instructions in

the literature accompanying this product.

4

Summary of Contents for Da Capo 75

Page 1: ... just pure and real udo roesner amps cook book acoustics roesner udo Da Capo75 ...

Page 2: ...all Check mains 8 4 1a Cable up properly 8 4 2 Gain Structure Level Adjustment 8 5 Controls and Connections Functions 8 5 1 Tone Switch Tone Control Hp Filter 8 5 2 Effect 9 5 3 Footswitch 10 5 4 Phantom Power 10 5 5 Phones 11 5 6 Send Return external loop 11 5 7 Line out 11 5 8 Aux in 11 5 9 DI out 11 5 10 Mains voltage modul 11 6 Technical Data 12 7 Jumper Position 14 8 Blockdiagram 16 manual 2 ...

Page 3: ...nd enchant with euphony With the Da Capo75 you have acquired a wonderful tool that will help you to perfom magic What and how you play into it will be played back completely relaxed with ease and unaltered The handling is simple it is clearly structured and it just does what it is supposed to do Nevertheless please take a moment to read the following opera ting instructions We have taken an effort...

Page 4: ...self 9 The device should not be installed or used close to strong electromagnetic fields such as large mains trans formers revolving machines neon illumination etc 10 Pay attention to an unhindered air circulation around the amp Never obstruct air vents or grilles 11 Do not expose the device to sudden changes in tempe rature to avoid malfunction or damage due to moisture condensation inside Secure...

Page 5: ... left unused for a long period of time Use only dry cloth for cleaning Avoid the use of detergents and do not let any liquids seep into the unit 20 Do not place any open sources of fire like candles on the device 21 Care should be taken so that objects do not fall onto the device and liquids are not spilled into the enclosu re through openings Ensure that no objects filled with liquids such as vas...

Page 6: ...ector only for microphones clip overload indicator 6 dBV headroom gain input level control range 40 dBV tone sound filter preset not active active bass low frequency tone control 8 dB at 100 Hz middle mid frequency tone control 6 dB at 800 Hz treble high frequency tone control 8 dB at 10kHz hpf high pass filter adjustment 40 Hz to 350 Hz pan effect pan control signal distribution between ch1 and c...

Page 7: ...external effect efx return signal input from external effect line 2 line signal output high level e g mixing console line 1 line signal output 10 dB e g soundcard aux in auxiliary input stereo TRS 3 5mm jack socket DI ch 2 XLR direct out channel 2 balanced DI ch 1 XLR direct out channel 1 balanced mains power connector module IEC connector cold appliance socket mains fuse 1 AT slow blow EU 2 AT sl...

Page 8: ...ls and the master control are in zero left stop and the tone controls in center position You may now switch the device on The power switch on the backside is illuminating in red The green power control LED on the top will indicate readi ness for operation 4 2 Gain Structure Level Adjustment Note A little care should be taken to set the signal level ratios conscious ly and correctly The DaCapo is n...

Page 9: ... Features 5 1 tone control tone switch hpf filter The DaCapo 75 is equipped with active high quality three tone bass treble middle eq channel 1 hpf bass treble middle eq channel 2 band tone controls in each channel Bass and treble are laid out as shelving filters The design reflects the ranges of instrument and voice whilst offering practical easy to use access to accentuation of your tone With th...

Page 10: ...ack side send to input return to output of the additional device The intensity of the external effect has to be adjusted at the external effects unit 5 3 Footswitch Any standard latching double footswitch 2 x on off can be connected to the switch socket at the backside of the amplifier by stereo TRS connector Switch one connected to tip will switch the internal effect on off while switch two conne...

Page 11: ...ng connected to e g mixing consoles Line 1 has less output and allows e g a soundcard to be connected directly with less risk of distorting the digital input of the soundcard 5 8 aux in Aux in is an additional 3 5mm TRS stereo input to connect your playback device to Left and right channel of your playback device are mixed and directly forwarded to the power amp 5 9 DI ch 1 DI ch 2 The device offe...

Page 12: ...d OFF aux in TRS stereo input 3 5mm OUTPUTS phones headphones jack socket stereo L R connected 6 35 mm input Impedance 470 Ohm common for L and R Please note Use TRS Stereo Jacks only Does not work with mono jacks When plugged in internal speaker is muted send jack socket unbalanced 6 35 mm pre master output voltage 1 4 V 3 dBV line out 1 and 2 jack socket unbalanced preamp out 6 35 mm post effect...

Page 13: ...______________ _____________________________________________________ channel 2 hpf filter 40Hz to 350 Hz bass 8 dB at 100 Hz shelf type middle 6 dB at 800 Hz treble 8 dB at 10 kHz shelf type EFFECTS effect presets 1 reverb short 2 reverb long 3 chorus 4 custom delay 5 my delay 6 tap n delay external effect parallel effect loop see also send and return efx pan blends both internal and external effe...

Page 14: ... ch2 on off default on phantom power JP7 phantom power ch1 on off default on JP8 phantom power ch2 on off default on direct out JP9 DI ch 1 pre or post EQ default pre JP10 DI ch2 pre or post EQ default pre Footswitch JP11 ring internal effect parameter or external effect loop on off default internal effect parameter jumper settings may only be carried out by qualified service personnel and when th...

Page 15: ...Block Diagram V 1 Da Capo 75 Sheet 1 1 190626 TM acoustics roesner udo 8 Block diagram 15 ...

Page 16: ... udo amps com MARco labs s a s udo roesner amps are designed and developed in Germany and France by udo roesner and MARco labs Produced in Indonesia with pleasure and great care acoustics roesner udo ML_DMA DC75 UK 200417 ...