background image

USE WZ-1000A MODULE

1. SELECTION OF MUSIC ZONES:

2. ANNOUNCEMENTS BY THE ENACTMENT OF THE WZ-1000A DESK:

3. ANNOUNCEMENTS BY THE ENACTMENT OF THE PZ-1000 DESK: See use PZ-1000 desk.

4. SPECIAL ALARM FEATURES:

By the selector MUSIC / EVENTS (MUSIC / CALL) with the corresponding driver in green, select the buttons SELECTORS
ZONE (ZONE PAGING), or areas you want the music.
Green pilot light: area with music.
Green pilot disabled: an area without music.
The selector GENERAL AREAS (ALL AREAS) can also select / deselect all areas of music at once.

SELECTING ADVERTISEMENTS: Operate the selector MUSIC / ANNOUNCEMENTS; the red driver.
Or select the areas you want to enact the announcement by the ZONE SELECTORS, or with the GENERAL selector. The
selected areas turn red (If there's selected music in the area, in orange).
At the end of the notice, deselect areas review and carry out the inverse of the selection.
The promulgation of the GENERAL notice in the WZ-1000A module affects only the 10 areas of this module.
In addition the selection in local mode is possible to control the PZ-1000A desk. The selections and actions in the WZ-1000A
desk take precedence over affected from the desk PZ-1000A.

The DIP switch number 6 must be in OFF position in order to enable the special alarm features.
When the A or B input is triggered, with a close contact, all the WZ-1000A zones would be connected to the alarm amplifier. In
the front panel will flash on in red or orange.
At the same time alarm OUT A/B of all WZ-1000A connected on the system will close free voltage contact.
An instant reset could be done, pushing the all zone button, realizing all zones system (in case more than one WZ-1000A is
installed).

PRIORITIES:

Manual selection in the module areas WZ-1000A has priority on the desks PZ-1000A.
When there is more of one desk in the PZ-1000A system, must consider the following:

PZ-1000A consoles have the same priority among themselves. The first that select a zone takes control of the system until is
deselected.
If a desk PZ-1000A tries to select a certain area, while another is a function, the LEDs light up quickly and deactivate.
If a desk PZ-1000A seeking access to nonexistent package, the LEDs flash slowly and deactivate.

USE PZ-1000A DESK

PZ-1000A /   WZ-1000A

9

6

610.490A

rev.

2

Summary of Contents for PZ-1000A

Page 1: ...on independently or bus operated by the desk PZ 1000A It allows the areas of music and announcements selection It integrates mixer with microphone inputs line and chime notice The system allows a maxi...

Page 2: ...G WZ 1000A 10 ZONES ACTIVATION GENERAL NOTICE ACTIVATION SELECTED AREA LED Button LED button LED button LED button LED button CARILLON ACTIVATION WZ 1000A indicator selected TALK Microphone ON OFF ANN...

Page 3: ...z to 18 Khz 80 dB 90 dB 230 VAC 40 W 2 microphone inputs not balanced 2 line inputs not balanced SPECIFICATIONS WZ 1000 200 mV 10K 1 8 mV 600 Properties work by modulating Vox The microphone input has...

Page 4: ...NGE ORANGE WHITE 1 2 3 4 5 6 7 8 BLUE BLUE WHITE BROWN BROWN WHITE GREEN GREEN WHITE ORANGE ORANGE WHITE ADDRESS 1 2 3 4 5 6 ON OFF Figura 2 1 a 10 11 a 20 21 a 30 31 a 40 41 a 50 51 a 60 61 a 70 71 a...

Page 5: ...s CHIME OF NOTICE Press the corresponding button CHIME ON The associated LED lights while the chime sounds in the selected area NOTICE By the button MIC ON OFF turn the microphone The pilot lights Giv...

Page 6: ...s possible to control the PZ 1000A desk The selections and actions in the WZ 1000A desk take precedence over affected from the desk PZ 1000A The DIP switch number 6 must be in OFF position in order to...

Page 7: ...H 2 MUSIC IN ALARM IN OUTPUT CH 3 CH 3 MUSIC IN ALARM IN OUTPUT CH 4 CH 4 MUSIC IN ALARM IN OUTPUT CH 5 CH 5 MUSIC IN ALARM IN OUTPUT CH 6 CH 6 MUSIC IN ALARM IN OUTPUT CH 7 CH 7 MUSIC IN ALARM IN OUT...

Page 8: ...UT THE RESISTANCE AS IF SHOWN IMPORTANT A WZ 1000A used with L100V should not be reused with 0 dB signal M dB WZ 1000A odification to operate with 0 audio signals R1 R2 R1 R3 R4 R5 R6 R7 R8 R9 R10 4 7...

Page 9: ...MUSIC IN ALARM IN OUTPUT CH 1 CH 1 MUSIC IN ALARM IN OUTPUT CH 2 CH 2 MUSIC IN ALARM IN OUTPUT CH 3 CH 3 MUSIC IN ALARM IN OUTPUT CH 4 CH 4 MUSIC IN ALARM IN OUTPUT CH 5 CH 5 MUSIC IN ALARM IN OUTPUT...

Reviews: