ZOE-M8B - System Integration Manual
UBX-17045131 - R04
Contents
Page 13 of 42
Production Information
user-defined update periods from 1 s up to 10 s. The Continuous Mode has two predefined settings,
full power and balanced.
For specific power saving applications, the host system has an option to put the receiver into backup
state. All essential data for quick re-starting of navigation can be saved either on the receiver or on
the host processor side.
☞
Unlike some other u-blox M8 receivers, the ZOE-M8B GNSS SiP does not support self-managed
ON/OFF power saving mode, in which the receiver periodically puts itself into backup state when
an operation interval longer than 10 s is selected.
Figure 9: ZOE-M8B Power modes.
Figure 10: ZOE-M8B Super-E mode configuration options.