background image

 

LEA-M8S / LEA-M8T - Hardware integration manual 

UBX-15030060 - R06 

Product handling  

Page 24 of 33 

Production information 

 

 

Repeated reflow soldering 

Only  single  reflow  soldering  processes  are  recommended  for  boards  populated  with  u-blox  M8 
modules. To avoid upside down orientation during the second reflow cycle, the M8 modules should not 
be submitted to two reflow cycles on a board populated with components on both sides. In  such a 
case, the module should always be placed on that side of the board which is submitted into the last 
reflow cycle. This is because of the risk of the module falling off due to the significantly higher weight 
in relation to other components.  

You can consider two reflow cycles by excluding the above described upside down scenario and taking 
into account the rework conditions described in section 4. 

 

Repeated  reflow  soldering  processes  and  soldering  the  module  upside  down  are  not 
recommended. 

Wave soldering 

Baseboards  with  combined  through-hole  technology  (THT)  components  and  surface-mount 
technology (SMT) devices require wave soldering to solder the THT components. Only a single wave 
soldering process is encouraged for boards populated with u-blox M8 modules. 

Hand soldering 

Hand soldering is allowed. Use a soldering iron temperature-setting equivalent to 350 °C. Place the 
module precisely on the pads. Start with a cross-diagonal fixture soldering (for example, pins 1 and 
15), and continue from left to right. 

Rework 

The u-blox M8 module can be unsoldered from the baseboard using a hot air gun. When using a hot 
air gun for unsoldering the module, a maximum of one reflow cycle is allowed. Using a hot air gun is 
not recommended because it is an uncontrolled process and might damage the module.  

 

Attention: use of a hot air gun can lead to overheating and severely damage the module. Always 
avoid overheating the module. 

After the module is removed, clean the pads before placing and hand soldering a new module. 

 

Never attempt a rework on the  module  itself,  for example, by replacing  individual  components. 
Such actions immediately terminate the warranty. 

In  addition  to  the  two  reflow  cycles,  manual  rework  on  particular  pins  by  using  a  soldering  iron  is 
allowed. Manual rework steps on the module can be done several times. 

Conformal coating 

Certain applications employ a conformal coating of the PCB using HumiSeal

®

 or other related coating 

products. These materials affect the HF properties of the GNSS module and it is important to prevent 
them from flowing into the module. The RF shields do not provide 100% protection for the module 
from coating liquids with low viscosity; therefore, take care when applying the coating. 

 

Conformal coating of the module will void the warranty. 

Casting 

If casting is required, use viscose or another type of silicon pottant. The OEM is strongly advised to 
qualify  such  processes  in  combination  with  the  u-blox  M8  module  before  implementing  it  in  the 
production. 

 

Casting will void the warranty. 

Summary of Contents for LEA-M8S

Page 1: ...S LEA M8T u blox M8 concurrent GNSS modules Hardware integration manual Abstract This document describes the features and specifications of u blox LEA M8S and LEA M8T modules www u blox com UBX 150300...

Page 2: ...Document contains the final product specification This document applies to the following products Product name Type number Firmware version PCN reference LEA M8S LEA M8S 0 10 ROM SPG 3 01 UBX 1601275...

Page 3: ...ESET_N Reset 8 1 5 2 EXTINT External interrupt 8 1 5 3 SAFEBOOT_N 8 1 5 4 D_SEL Interface select LEA M8T only 9 1 5 5 Antenna open circuit detection ANT_DET_N 9 1 5 6 TIMEPULSE 9 1 5 7 TIMEPULSE 2 LEA...

Page 4: ...tion LEA 6T LEA M8T 21 3 4 Software migration 21 4 Product handling 22 4 1 Packaging shipping storage and moisture preconditioning 22 4 2 Soldering 22 4 3 EOS ESD EMI precautions 25 4 4 Applications w...

Page 5: ...supply pins VCC V_BCKP and VDD_USB 1 3 1 VCC Main supply voltage The VCC pin provides the main supply voltage During operation the current drawn by the module can vary by some orders of magnitude esp...

Page 6: ...ailable to provide antenna bias voltage to supply an optional external active antenna For more information see section 2 4 If not used connect the V_ANT pin to GND 1 4 Interfaces 1 4 1 UART The LEA M8...

Page 7: ...down to a voltage of 3 3 V Almost no current requirement 1 mA C23 C24 Capacitors Required according to the specification of LDO U1 D2 Protection diodes Protect circuit from overvoltage ESD when conne...

Page 8: ...e RTC time is also reset but not BBR 1 5 2 EXTINT External interrupt EXTINT0 and EXTINT1 are external interrupt pins with fixed input voltage thresholds with respect to VCC see the LEA M8S Data sheet...

Page 9: ...ULSE 2 LEA M8T only A configurable TIMEPULSE2 signal is available on LEA M8T module only For more information see the u blox 8 u blox M8 Receiver Description Including Protocol Specification 3 1 6 Ele...

Page 10: ...LEA M8S LEA M8T Hardware integration manual UBX 15030060 R06 Hardware description Page 10 of 33 Production information Figure 3 EMI Precautions...

Page 11: ...a bias voltage Connect to GND or leave open if passive antenna is used If an active antenna is used add a 10 resistor in front of V_ANT input to the antenna bias voltage or VCC_RF EXTINT1 20 I Ext int...

Page 12: ...open I Interface select D_SEL 0 SPI D_SEL 1 or open DDC Reserved 9 21 22 23 Reserved Leave open Table 2 Pinout LEA M8S LEA M8T 2 1 1 Pin name changes Selected pin names have been updated to agree wit...

Page 13: ...3 Footprint and paste mask Figure 5 describes the footprint and provides recommendations for the paste mask for the LEA M8S and LEA M8T modules These are recommendations only and not specifications N...

Page 14: ...gn with passive antenna A design using a passive antenna requires more attention to the layout of the RF section Typically a passive antenna is located near electronic components therefore take care t...

Page 15: ..._RF output can be used to supply the LNA with a filtered supply voltage A standard GNSS LNA has enough bandwidth to amplify GPS Galileo GLONASS and BeiDou signals 2 4 2 Active antenna design Active an...

Page 16: ...nally powered active antenna This circuit has to be used if the active antenna has a different supply voltage than the VCC_RF for example if a 5 V active antenna is used Figure 10 Active antenna desig...

Page 17: ...t detection antenna supervisor If a suitably dimensioned R_BIAS series resistor is placed in front of the V_ANT pin a short circuit can be detected in the antenna supply The detection happens inside t...

Page 18: ...y should be free of noise Usually low frequency analog noise is less critical than digital noise of spurious frequencies with harmonics up to the GPS QZSS band of 1 575 GHz GLONASS band of 1 602 GHz a...

Page 19: ...ment During design in do not place the module near sources of heating or cooling The receiver oscillator is sensitive to sudden changes in ambient temperature which can adversely impact satellite sign...

Page 20: ...ck No difference 3 TxD Serial port TXD Serial port No difference 4 RxD Serial port RXD Serial port No difference 5 NC Not connected Reserved Not connected No difference 6 VCC Supply voltage VCC Supply...

Page 21: ...u blox 6 module OK to do the same in M8 12 Reserved Safeboot_N TP2 SAFEBOOT _N Safeboot_N Time pulse 2 Must not be held LO during start up 13 GND Ground GND Ground No difference 14 GND Ground GND Grou...

Page 22: ...the solder joints on the connectors half vias must meet the appropriate IPC specification Reflow soldering A convection type soldering oven is highly recommended over the infrared type radiation oven...

Page 23: ...ng the u blox M8 module consider an optical inspection step to check whether The module is properly aligned and centered over the pads All pads are properly soldered No excess solder has created conta...

Page 24: ...ering for example pins 1 and 15 and continue from left to right Rework The u blox M8 module can be unsoldered from the baseboard using a hot air gun When using a hot air gun for unsoldering the module...

Page 25: ...cost effective solutions To avoid overstress damage during production or in the field it is essential to observe strict EOS ESD EMI handling and protection measures To prevent overstress damage at th...

Page 26: ...module ESD protection measures GNSS positioning modules are sensitive to electrostatic discharge ESD Special precautions are required when handling For more robust designs employ additional ESD prote...

Page 27: ...gure 16 EOS and ESD precautions Electromagnetic interference EMI Electromagnetic interference EMI is the addition or coupling of energy causing a spontaneous reset of the GNSS receiver or resulting in...

Page 28: ...If such isolation cannot be achieved for example in the case of an integrated cellular GNSS antenna an additional input filter is needed on the GNSS side to block the high energy emitted by the GSM t...

Page 29: ...band interference is caused by signal frequencies that are different from the GNSS carrier see Figure 19 The main sources are wireless communication systems such as cellular CDMA WCDMA Wi Fi BT and s...

Page 30: ...data sheet basis only Other components may also be used Manufacturer Part ID Remarks Parameters to consider Diode ON Semiconductor ESD9R3 3ST5G Standoff voltage 3 3 V Low capacitance 0 5 pF ESD9L3 3ST...

Page 31: ...lithic type For data signals 34 pF load capacitance NFA18SL307V1A45 Array type For data signals 4 circuits in 1 package Feed through capacitor Murata NFM18PC NFM21P 0603 2A 0805 4A Rs 0 5 Resistor 10...

Page 32: ...regular updates to u blox documentation and to receive product change notifications register on our homepage www u blox com Revision history Revision Date Name Comments R01 12 Feb 2016 jfur Objective...

Page 33: ...p u blox com Regional Office China Beijing Phone 86 10 68 133 545 E mail info_cn u blox com Support support_cn u blox com Regional Office China Chongqing Phone 86 23 6815 1588 E mail info_cn u blox co...

Reviews: