background image

 

EVK-L2 - User guide 

UBX-14000422 - R11 

Starting up

  

Page 10 of 27 

C1-Public  

 

DIL B2B J201 

 

DIL B2B J200 

Signal Name 

Pin N°  Pin N° 

Signal Name 

 

Signal Name 

Pin N°  Pin N° 

Signal Name 

HOST_SELECT0 

GND 

 

Not connected 

GND 

Not connected 

V_BCKP 

 

Not connected 

Not connected 

Not connected 

Not connected 

 

Not connected 

Not connected 

GND 

GND 

 

VCC 

VCC 

GND 

10 

GND 

 

VCC 

10 

VCC 

DTR 

12 

11 

DCD 

 

Not connected 

12 

11 

Not connected 

CTS 

14 

13 

RTS 

 

SIM_IO 

14 

13 

VSIM 

RXD 

16 

15 

TXD 

 

SIM_RST 

16 

15 

SIM_CLK 

DSR 

18 

17 

RI 

 

Not connected 

18 

17 

Not connected 

Not connected 

20 

19 

Not connected 

 

SCL 

20 

19 

Not connected 

Not connected 

22 

21 

Not connected 

 

Not connected 

22 

21 

SDA 

Not connected 

24 

23 

GPIO5 

 

Not connected 

24 

23 

Not connected 

Not connected 

26 

25 

GPIO4 

 

RESET_N 

26 

25 

Not connected 

Not connected 

28 

27 

Not connected 

 

MIC_BIAS 

28 

27 

MIC_GND 

Not connected 

30 

29 

PWR_ON 

 

Not connected 

30 

29 

Not connected 

GPIO3 

32 

31 

GPIO2 

 

Not connected 

32 

31 

Not connected 

HOST_SELECT1 

34 

33 

GPIO1 

 

SPK_N 

34 

33 

SPK_P 

V_INT 

36 

35 

Not connected 

 

Not connected 

36 

35 

Not connected 

Not connected 

38 

37 

Not connected 

 

Not connected 

38 

37 

Not connected 

Not connected 

40 

39 

Not connected 

 

Not connected 

40 

39 

Not connected 

GND 

42 

41 

GND 

 

GND 

42 

41 

Not connected 

Table 5: Pin-out of the 42-pin Dual-In-Line Board-to-Board connectors (J201, J200) available on the adapter board ADP-L2 
of the EVK-L2 evaluation kit for TOBY-L2 series modules 

 

 

The pins / interfaces that are not supported by a specific TOBY-L2 module product version should 
be not driven by an external device (see the TOBY-L2 series data shee

[3]

 and TOBY-L2 / MPCI-L2 

series system integration manua

[4]

 for the features supported by each TOBY-L2 module product 

version). 

 

1.7

 

Software installation 

The  related  USB  drivers  are  available  with  the  EVK-L2.  Executable  files  can  be  downloaded  from 

www.u-blox.com/evk-downloads

  and  saved  to  any  location  on  the  computer  hard  drive.  The 

installation can be started by running the executable file on a computer with the Windows operating 
system. 

 

Summary of Contents for EVK-L2 Series

Page 1: ...ox com EVK L2 TOBY L2 series LTE DC HSPA EGPRS cellular evaluation kits User guide Abstract This guide explains how to set up the EVK L2x Evaluation Kits to begin evaluating the u blox TOBY L2 series...

Page 2: ...20033492 Mass production EVK L21 EVK L21 00S 02 15 63 A01 03 UBX 15029946 End of Life 15 63 A01 10 UBX 16031212 End of Life 17 00 A01 00 UBX 20033492 Mass production EVK L21 62S 01 16 05 A01 02 UBX 17...

Page 3: ...d 12 1 11Registration on a cellular network 13 1 12Enable audio codec configuration to provide voice capability 13 1 13Switching off the EVK L2 13 Appendix 14 A Setting up AT terminal applications for...

Page 4: ...01 evaluation kit is for evaluation of TOBY L210 62S EVK L22 evaluation kit is for evaluation of TOBY L201 in details o EVK L22 00S 00 evaluation kit is for evaluation of TOBY L201 02S EVK L23 evaluat...

Page 5: ...J103 GNSS module GNSS adapter board Cellular VCC supply jumper J404 Cellular USB UART J501 Cellular RS232 UART J500 DL501 DL403 DL405 GNSS USB J102 SW403 SW401 DL404 SW300 SW304 SW204 Headset jack J3...

Page 6: ...SB connector for the cellular module It also contains the u blox ELLA W1 series Wi Fi module and the Wi Fi antenna connector except for the EVK L24 and an audio codec The GNSS adapter board called ADP...

Page 7: ...DL401 EVB Cellular VCC Cellular module supplied Main Power Switch must be switched on DL400 EVB Cellular native USB USB cable plugged in Cellular native USB connector DS100 ADP L2 Cellular USB USB ca...

Page 8: ...n Line Board to Board connectors for cellular module interfaces J300 J3011 J200 J2012 ADP L2 Cellular headset Audio headset jack connector for cellular module audio interface J303 EVB GNSS antenna SMA...

Page 9: ...SVD Not present 16 TXD J201 Pin 15 47 RSVD Not present 78 GND J201 Pins 7 10 17 RXD J201 Pin 16 48 RSVD Not present 79 GND J201 Pins 7 10 18 RSVD Not present 49 RSVD Not present 80 GND J201 Pins 7 10...

Page 10: ...3 32 31 GPIO2 Not connected 32 31 Not connected HOST_SELECT1 34 33 GPIO1 SPK_N 34 33 SPK_P V_INT 36 35 Not connected Not connected 36 35 Not connected Not connected 38 37 Not connected Not connected 3...

Page 11: ...V Power Input connector J400 on the EVB LED DL401 lights blue 7 Be sure to provide a jumper socket on the Cellular VCC supply jumper J404 on the EVB This provides the connection from the 3 8 V output...

Page 12: ...n the adapter board cellular UART detached from USB UART J501 and RS232 UART J500 connectors B2B Do not care DL404 Table 6 Serial interface configuration Run an AT terminal application e g the u blox...

Page 13: ...L2 Check the configuration of the GPIO6 pin gpio_id 61 it must be configured as clock output gpio_mode 14 as the factory programmed value to provide voice capability at the headset jack connector usi...

Page 14: ...r the setting values see section 1 8 Check with the Windows Device Manager to find out which COM port is being used by EVK L2 Figure 3 Home page 4 Enable the connection to u blox cellular module by cl...

Page 15: ...m it OK Define a PDP context with preferred APN in this example the ibox tim it APN is selected AT UCGDFLT 1 IP ibox tim it OK Define the initial PDP context with preferred APN This will be activated...

Page 16: ...EVK L2 User guide UBX 14000422 R11 Appendix Page 16 of 27 C1 Public 2 Open Network and Sharing Center and click on Local Area Connection associated to RNDIS interface 3 Click on Properties...

Page 17: ...422 R11 Appendix Page 17 of 27 C1 Public 4 Search for Internet Protocol Version 4 TCP IPv4 and click on Properties 5 Check the Obtain an IP address automatically and Obtain DNS server address automati...

Page 18: ...ide UBX 14000422 R11 Appendix Page 18 of 27 C1 Public 6 If it is not possible to surf the web then manually set the DNS server address for example use the DNS server returned by network in this exampl...

Page 19: ...following AT command lines Perform the following procedure to activate an external PDP context with the preferred APN Command sent by DTE user DCE response module Description AT UBMCONF UBMCONF 1 OK...

Page 20: ...er address in this example the DNS primary server address is 83 224 70 94 For the complete description and syntax of supported AT commands and for further details regarding all the settings configurab...

Page 21: ...CM interface The configuration can be set by means of the UUSBCONF AT command see the u blox AT commands manual 1 On a Linux OS to reach the highest throughput through the RNDIS it is necessary to rec...

Page 22: ...he u blox TOBY L2 series networking modes application note 5 E 1 Enable communication between cellular and Wi Fi module Command sent by DTE user DCE response module Description AT UGPIOC UGPIOC 10 15...

Page 23: ...llular module 42 pin DIL B2B connectors EVB WL3 Step Down Main power switch SW400 12 V J400 3 8 V VCC DigitalMultimeter DCI VCC jumper J404 R118 R115 jumpers Figure 6 Block diagram of current consumpt...

Page 24: ...al Packet Radio Service EVB Evaluation Board EVK Evaluation Kit GND Ground GNSS Global Navigation Satellite System GPIO General Purpose Input Output HSPA High Speed Packet Access I2C Inter Integrated...

Page 25: ...r usage It is the user s duty to verify if further restrictions apply such as in airplanes hospitals or hazardous locations such as petrol stations or refineries Any changes or modification made to th...

Page 26: ...rections R03 27 Nov 2014 sses Updated document status to Early Production Information Updated EVK L2 description including EVB WL3 instead of EVB WL1 R04 07 May 2015 sses Added EVK L22 EVK L23 evaluat...

Page 27: ...nal Office China Beijing Phone 86 10 68 133 545 Email info_cn u blox com Support support_cn u blox com Regional Office China Chongqing Phone 86 23 6815 1588 Email info_cn u blox com Support support_cn...