6.6.
Send the CONFIG GET message.
6.7.
A dialog similar to the one shown below is displayed and can be used to validate the
configurations.
☞
A configuration entry can be overwritten by sending a new CONFIG SET message with the same
unit and source.
☞
All configuration entries can be deleted with the CONFIG CLEAR message.
5.5
Updating the MCU firmware
New MCU firmware and corresponding tool versions may be released e.g. to support new features or
to increase the performance of the application. To update the firmware, the following equipment is
required:
•
Silicon Labs IDE or Flash Programming Utilities software [10], and
•
USB debug adapter for 8-bit MCUs [11].
To flash the new firmware:
1.
Power up the device.
2.
Connect the debugger to the 10-pin rear connector.
3.
If using the Silicon Labs IDE:
a.
Select
Debug > Connect
to connect the Debugger to the MCU.
b.
Select
Debug > Download
object file
and input the correct file to the opened window.
c.
Select
Download
to start the flashing process.
4.
If using Flash Programming Utilities, follow the instructions accompanying the software.
5.
After the device is flashed, disconnect the debugger and reboot the device.
6.
Confirm that the firmware version string matches by either checking what the MCU outputs
during bootup, or by sending a FW GET command.
Summary of Contents for EVK-F9DR
Page 29: ...EVK F9DR User guide UBX 23007618 R01 Appendix Page 29 of 33 C1 Public...
Page 30: ...EVK F9DR User guide UBX 23007618 R01 Appendix Page 30 of 33 C1 Public D Schematic...
Page 31: ...EVK F9DR User guide UBX 23007618 R01 Appendix Page 31 of 33 C1 Public...
Page 32: ...EVK F9DR User guide UBX 23007618 R01 Appendix Page 32 of 33 C1 Public...