*3.9 Configuration CC – Continue
Type
Parameter
No.
Description
Size
Value
Default
Hex
Dec
Temperature
Sensor
(Cont.)
0x25
37
Name: Overheat Recover Value
Info: Configure overheat recover report value
2 Bytes 0x0000~0x00FF = Set °C value
0x0100~0x01FF = Set °F value
0x0030=°C
0x0156=°F
0x26
38
Name: Association Group 4 Overheat Trigger Value
Info: Configure overheat trigger SET value
1 Byte
0x00 = Disable
0x01 = Send Basic ON (0xFF)
0x02 = Send Basic OFF (0x00)
0x00
0x27
39
Name: Association Group 4 Overheat Cancellation Value
Info: Configure overheat cancellation SET value
1 Byte
0x00 = Disable
0x01 = Send Basic ON (0xFF)
0x02 = Send Basic OFF (0x00)
0x00
0x28
40
Name: Freeze Trigger Value
Info: Configure Freeze Trigger Report Value
2 Bytes 0x0000~0x00FF = Set °C value
0x0100~0x01FF = Set °F value
0x0000 = 0°C
0x0120 = 0°F
0x29
41
Name: Freeze Recover Value
Info: Configure Freeze Recover Report Value
2 Bytes 0x0000~0x00FF = Set °C value
0x0100~0x01FF = Set °F value
0x0004 = 4°C
0x0128 = 40°F
0x2A
42
Name: Freeze Detection Valve Control Forbidden
Info: Enable / Disable valve control when freeze detection
1 Byte
0x00 = Allowed
0x01 = Forbidden
0x00
0x2B
43
Name: Association Group 5 Freeze Trigger
Info: Configure freeze trigger SET value
1 Byte
0x00 = Disable
0x01 = Send Basic ON (0xFF)
0x02 = Send Basic OFF (0x00)
0x00
0x2C
44
Name: Association Group 5 Freeze Cancellation
Info: Configure freeze cancellation SET value
1 Byte
0x00 = Disable
0x01 = Send Basic ON (0xFF)
0x02 = Send Basic OFF (0x00)
0x00
Water Leak
0x31
49
Name: Association Group 3 Water Leak Trigger Value
Info: Configure Water Leak Trigger SET value
1 Byte
0x00 = Disable
0x01 = Send Basic ON (0xFF)
0x02 = Send Basic OFF (0x00)
0x01
0x32
50
Name: Association Group 3 Water Leak Cancellation Value
Info: Configure Water Leak Cancellation value
1 Byte
0x00 = Disable
0x01 = Send Basic ON (0xFF)
0x02 = Send Basic OFF (0x00)
0x00
0x33
51
Name: Water Leak Detection
Info: Enable / Disable Water Leak Detection
1 Byte
0x00 = Disable
0x01 = Enable
0x01