![Ubisys S1 Reference Manual Download Page 33](http://html1.mh-extra.com/html/ubisys/s1/s1_reference-manual_3153250033.webp)
33
www.ubisys.de
u
4
Press Button A
Turns the output on
Press Button B
Turns the output off
Press Button C
Toggles the output, i.e. turns it on when it is off, and turns it off when it is on
Press Button D
Toggles the output, i.e. turns it on when it is off, and turns it off when it is on
7.8.2.
Green Power Cluster (Client)
The client-side of the Green Power cluster provides the ZigBee Green Power Proxy functionality, i.e.
makes the device act as an “access point” for Green Power Devices (GPDs). This implementation
supports unidirectional and bidirectional
27
GPDs.
Attributes supported:
Attribute
Type
Description
0x0010
unsigned8,
read-only
gppMaxProxyTableEntries
The number of proxy table entries supported by this device
0x0011
extended raw
binary,
read-only,
persistent
ProxyTable
Entries in the proxy table create a link between Green Power Devices and Green Power Sinks
0x0016
bitmap24,
read-only
gppFunctionality
Indicates Green Power features and building blocks supported by this device
0x0017
bitmap24,
read-only
gppActiveFunctionality
Allows to disable certain Green Power features on this device
0x0020
bitmap8,
persistent
gpSharedSecurityKeyType
Determines the security key type to use for devices with bidirectional commissioning
capabilities, i.e. out-of-the-box individual key, shared GP key, etc.
0x0021
key128,
persistent
gpSharedSecurityKey
The 128-bit AES-CCM* key that is being used to secure Green Power data frames
0x0022
key128,
persistent
gpLinkKey
The 128-bit AES-CCM* key that is being used to deliver keying material to Green Power
devices
Cluster commands supported:
Command
Description
0x01
GP Pairing
Creates, updates or removes proxy table entries
0x02
GP Proxy Commissioning Mode
Makes the proxy enter commissioning mode for a particular sink, or leave commissioning mode
0x06
GP Response
Tunnels GP data frames from a sink to a bidirectional Green Power Device
0x0B
GP Proxy Table Request
Allows to query the proxy table for a certain Green Power Device or read out the table in chunks
Cluster commands transmitted:
27
Bidirectional communication is currently limited to the commissioning stage