background image

Accessing airOS

Verify connectivity in the airOS Configuration Interface. 
1.  Make sure that your host machine is connected via 

Ethernet to the PowerBeam. 

2.  Configure the Ethernet adapter on your host system with a 

static IP address on the 192.168.1.x subnet.

3.  Launch your web browser and type https://192.168.1.20 

in the address field. Press enter (PC) or return (Mac). 

4.  The login screen will appear. Enter ubnt in the Username 

and Password fields. Select your Country and Language
You must agree to the Terms of Use to use the product. 
Click Login.

Note:

 U.S. product versions are locked to the 

U.S. Country Code to ensure compliance with 
FCC regulations. 

Summary of Contents for PowerBeam m5 iso PBE-M5-300-ISO

Page 1: ...5 GHz airMAX Bridge with 300 mm RF Isolated Reflector Model PBE M5 300 ISO...

Page 2: ...135 Qty 2 5 GHz airMAX Bridge with 300 mm RF Isolated Reflector Model PBE M5 300 ISO PoE Adapter 24V 0 5A with Mounting Bracket Power Cord Quick Start Guide TERMS OF USE Ubiquiti radio devices must be...

Page 3: ...Hardware Overview Bottom View Cable Door Rear Housing Antenna Feed Ethernet Port Release Button Slot Mounting Bracket Release Button Reflector Alignment Pins Reset Button Radome...

Page 4: ...depress the Release button first LEDs Signal In airOS you can modify the wireless signal strength threshold values for each LED on the Advanced tab under Signal LED Thresholds The default values are s...

Page 5: ...age using the 3 dBi Antenna Feed only Installation Requirements 13 mm wrench Shielded Category 5 or above cabling should be used for all wired Ethernet connections and should be grounded through the A...

Page 6: ...cket into the slots of the Reflector Rotate the Mounting Bracket counter clockwise until the tabs lock into place 2 Line up the Alignment Pins of the Rear Housing with the alignment holes of the Mount...

Page 7: ...elow of the Rear Housing are fully engaged with the inner wall of the Reflector and locked into place Important Before proceeding lightly pull the Rear Housing to confirm that it is locked into place...

Page 8: ...it locks into place with a click b Lightly pull the Antenna Feed to ensure that it is locked into place and the Release Button is fully engaged Release Button Bottom View 6 Connect an Ethernet cable t...

Page 9: ...icator Slot on the left b Insert the Carriage Bolts through the holes of the Adjustment Bracket c Slide the hole of the Pole Clamp over one bolt of the Adjustment Bracket d Place one Flange Nut on eac...

Page 10: ...it a Place the Adjustment Bracket against the pole b Slide the slot of the Pole Clamp over the Carriage Bolt c Tighten the Flange Nuts of the bolts to 25 N m to secure the antenna to the pole 25 N m N...

Page 11: ...sh Mark on the edge of the Radome with the Slot on the bottom of the Reflector Slot Hash Mark 11 Fit the Radome onto the Reflector Ensure that all eight Reflector tabs fit into the gaps between the ei...

Page 12: ...that the Snap Pin is seated in the slot in the bottom tab of the Reflector Snap Pin 13 Adjust the elevation angle a Loosen the four Hex Bolts on both sides of the antenna b Pivot the antenna until the...

Page 13: ...Ethernet port labeled POE on the PoE Adapter 15 Connect an Ethernet cable from your LAN or computer to the Ethernet port labeled LAN on the PoE Adapter 16 Connect the Power Cord to the power port on t...

Page 14: ...t from the PoE Adapter 2 Place the PoE Mounting Bracket at the desired location and mark the two holes Pre drill the holes if necessary and then secure the bracket using two fasteners not included 3 A...

Page 15: ...P address on the 192 168 1 x subnet 3 Launch your web browser and type https 192 168 1 20 in the address field Press enter PC or return Mac 4 The login screen will appear Enter ubnt in the Username an...

Page 16: ...drop down list select the appropriate option c Click Change to save d Click OK to confirm Customize additional settings as needed to complete the configuration For additional details on the airOS Conf...

Page 17: ...er s responsibility to make sure the device is operated within local country regulatory requirements Since Ubiquiti Networks equipment can be paired with a variety of antennas and cables the Antenna a...

Page 18: ...Ethernet Port Enclosure Outdoor UV Stabilized Plastic Max Power Consumption 6W Power Supply 24V 0 5A PoE Adapter Included Power Method Passive PoE Pairs 4 5 7 8 Return Wind Survivability 200 km h 125...

Page 19: ...rovided only by a qualified service technician 3 This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet a...

Page 20: ...V has been subjected to misuse abuse negligence abnormal physical electromagnetic or electrical stress including lightning strikes or accident V has been damaged or impaired as a result of using third...

Page 21: ...FACILITIES UBIQUITI NETWORKS ITS AFFILIATES AND ITS AND THEIR THIRD PARTY PROVIDERS ARE NOT RESPONSIBLE FOR ANY INTERRUPTIONS DELAYS CANCELLATIONS DELIVERY FAILURES DATA LOSS CONTENT CORRUPTION PACKET...

Page 22: ...must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class B digital device pursuan...

Page 23: ...luding interference that may cause undesired operation of the device This radio transmitter IC 6545A NBM5HP has been approved by Industry Canada to operate with the antenna types listed below with the...

Page 24: ...mp dance pour chacun Informations d antenne Antenne parabolique Gain 22 dBi RF Exposure Warning The antennas used for this transmitter must be installed to provide a separation distance of at least 20...

Page 25: ...ice or the shop where you purchased the product Deutsch Die Europ ische Richtlinie 2002 96 EC verlangt dass technische Ausr stung die direkt am Ger t und oder an der Verpackung mit diesem Symbol verse...

Page 26: ...insi que tout autre mat riel lectrique ou lectronique par les moyens de collecte indiqu s par le gouvernement et les pouvoirs publics des collectivit s territoriales L limination et le recyclage en bo...

Page 27: ...ch Par la pr sente UBIQUITI NETWORKS d clare que l appareil UBIQUITI NETWORKS est conforme aux exigences essentielles et aux autres dispositions pertinentes de la directive 1999 5 CE Deutsch German Hi...

Page 28: ...1999 5 ES Svenska Swedish H rmed UBIQUITI NETWORKS intygar att denna UBIQUITI NETWORKS enhet r i verensst mmelse med de v sentliga egenskapskrav och vriga relevanta best mmelser som framg r av direkt...

Reviews: