background image

ETH-SP-G2 Quick Start Guide

https://dl.ubnt.com/qsg/ETH-SP-G2/ETH-SP-G2_EN.html[1/20/2020 4:04:01 PM]

Note:

 If you are using a drain wire for grounding, proceed to 

“Connecting

Ethernet”

.

4. 

Summary of Contents for ETH-SP-G2

Page 1: ...nding Point Package Contents Hardware Overview Passive surge protected RJ45 Ethernet ports The ETH SP G2 must be grounded by one of the following methods Using the included Self Tapping Screw to ground the ETH SP G2 directly to a grounded metal pole or structure or Using an M5 machine screw and nut not included to attach a drain wire that is ETH SP G2 Quick Start Guide ...

Page 2: ...d Pole Mounting Drill with a 4 5 mm drill bit 1 Metal strap or cable tie Wall Mounting 2 Screws 5 mm screw head 1 M5 machine screw and nut 1 Drain wire 16 AWG 40 cm Optional Drain wire M5 machine screw and nut are not included Note Place the included Serrated Washer between the screw and drain wire Installation Install the ETH SP G2 near an Ethernet device Follow the appropriate steps for your ins...

Page 3: ...t com qsg ETH SP G2 ETH SP G2_EN html 1 20 2020 4 04 01 PM Pole Mounting A metal strap or cable tie is not included 1 Note If the Ethernet device is mounted on the pole with a metal strap you may use the same strap to attach the ETH SP G2 2 3 ...

Page 4: ...ETH SP G2 Quick Start Guide https dl ubnt com qsg ETH SP G2 ETH SP G2_EN html 1 20 2020 4 04 01 PM Note If you are using a drain wire for grounding proceed to Connecting Ethernet 4 ...

Page 5: ...ETH SP G2 Quick Start Guide https dl ubnt com qsg ETH SP G2 ETH SP G2_EN html 1 20 2020 4 04 01 PM 5 6 Proceed to Connecting Ethernet Wall Mounting ...

Page 6: ...ETH SP G2 Quick Start Guide https dl ubnt com qsg ETH SP G2 ETH SP G2_EN html 1 20 2020 4 04 01 PM 1 2 ...

Page 7: ...ETH SP G2 Quick Start Guide https dl ubnt com qsg ETH SP G2 ETH SP G2_EN html 1 20 2020 4 04 01 PM 3 ...

Page 8: ...ETH SP G2 Quick Start Guide https dl ubnt com qsg ETH SP G2 ETH SP G2_EN html 1 20 2020 4 04 01 PM 4 ...

Page 9: ...ETH SP G2 Quick Start Guide https dl ubnt com qsg ETH SP G2 ETH SP G2_EN html 1 20 2020 4 04 01 PM ...

Page 10: ...ETH SP G2 Quick Start Guide https dl ubnt com qsg ETH SP G2 ETH SP G2_EN html 1 20 2020 4 04 01 PM Connecting Ethernet ...

Page 11: ... Transient Current with Response to Surge Voltage from 100V s to 1kV µs DC Spark Over Voltage 90V 100V s Maximum Impulse Spark over Voltage 700V 1kV µs Discharge Current 15kV Maximum Insulation Resistance 1GΩ 50V Maximum Capacitance 1 0 pF 1 MHz Data Line Protection RJ45 10 100 1000 Ethernet IEEE 802 3af PoE Support Yes Shock and Vibration Certification ETSI300 019 1 4 Standard Operating Temperatu...

Page 12: ...ld be provided only by a qualified service technician 3 The equipment requires the use of the ground wire as a part of the safety certification modification or misuse can provide a shock hazard that can result in serious injury or death 4 Contact a qualified electrician or the manufacturer if there are questions about the installation prior to connecting the equipment 5 Protective earthing is prov...

Page 13: ...not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equip...

Page 14: ...ETH SP G2 Quick Start Guide https dl ubnt com qsg ETH SP G2 ETH SP G2_EN html 1 20 2020 4 04 01 PM 2020 Ubiquiti Inc All rights reserved ...